Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Lab Hematol ; 38(6): 648-657, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27571881

ABSTRACT

INTRODUCTION: Lumi-aggregometry quantification of platelet dense granule adenosine triphosphate (ATP) release is commonly used for diagnosing platelet function disorders. As the test findings show considerable variability for healthy controls, we postulated that patient findings might also be variable and investigated patients who were assessed for dense granule ATP release defects more than once. METHODS: Analyses were performed on prospectively collected data for first and second tests for subjects tested for dense granule ATP release defects more than once by the Hamilton Regional Laboratory Program (HRLMP) between January 2007 and June 2013 (cohort I). Similar analyses were performed for subjects who were recruited to a platelet disorder study (cohort II) and were assessed for ATP release defects more than once before October 2015. RESULTS: A total of 150 unique subjects had multiple ATP release tests. Results with individual agonists were variable for many subjects. While normal findings with all tested agonists were often confirmed by the second test (cohort I: 83%; cohort II: 100%), impaired release with multiple agonists was confirmed in only some subjects (cohort I: 34%; cohort II: 54%). Inconsistent findings were common (cohort I: 36%; cohort II: 39%). ISTH bleeding scores showed no relationship to the test findings. The finding of impaired ATP release with 2 or more agonists on both tests was not associated with an increased likelihood of a definite bleeding disorder. CONCLUSION: The variability in platelet dense granule ATP release findings amongst patients assessed for diagnostic purposes suggests that the test has limited value for diagnosing platelet disorders.


Subject(s)
Adenosine Triphosphate/metabolism , Blood Coagulation Disorders/diagnosis , Blood Platelet Disorders/diagnosis , Platelet Function Tests/methods , Cohort Studies , Hemorrhage , Humans , Platelet Function Tests/standards , Prospective Studies
2.
Thromb Haemost ; 107(4): 726-34, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22234747

ABSTRACT

Platelet aggregometry and dense granule adenosine triphosphate (ATP) release assays are helpful to diagnose platelet disorders. Some laboratories simultaneously measure aggregation and ATP release using Chronolume® a commercial reagent containing D-luciferin, firefly luciferase and magnesium. Chronolume® can potentiate sub-maximal aggregation responses, normalising canine platelet disorder findings. We investigated if Chronolume® potentiates human platelet aggregation responses after observing discrepancies suspicious of potentiation. Among patients simultaneously tested by light transmission aggregometry (LTA) on two instruments, 18/43 (42%), including 14/24 (58%) with platelet disorders, showed full secondary aggregation with one or more agonists only in tests with Chronolume®. As subjects with Quebec platelet disorder (QPD) did not show the expected absent secondary aggregation responses to epinephrine in tests with Chronolume®, the reason for the discrepancy was investigated using samples from 10 QPD subjects. Like sub-threshold ADP (0.75 µM), Chronolume® significantly increased QPD LTA responses to epinephrine (p<0.0001) and it increased both initial and secondary aggregation responses, leading to dense granule release. This potentiation was not restricted to QPD and it was mimicked adding 1-2 mM magnesium, but not D-luciferin or firefly luciferase, to LTA assays. Chronolume® potentiated the ADP aggregation responses of QPD subjects with a reduced response. Furthermore, it increased whole blood aggregation responses of healthy control samples to multiple agonists, tested at concentrations used for the diagnosis of platelet disorders (p values <0.05). Laboratories should be aware that measuring ATP release with Chronolume® can potentiate LTA and whole blood aggregation responses, which alters findings for some human platelet disorders, including QPD.


Subject(s)
Adenosine Triphosphate/metabolism , Factor V Deficiency/blood , Platelet Aggregation , Adenosine Diphosphate/chemistry , Benzothiazoles/metabolism , Blood Platelets/metabolism , Case-Control Studies , Epinephrine/chemistry , Factor V Deficiency/metabolism , Humans , Indicators and Reagents/pharmacology , Light , Luciferases/metabolism , Magnesium/metabolism , Platelet Aggregation Inhibitors/pharmacology , Platelet Function Tests/methods , Time Factors
3.
J Thromb Haemost ; 7(4): 676-84, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19143930

ABSTRACT

BACKGROUND: Light transmission aggregometry (LTA) is commonly performed to assess individuals for bleeding disorders. OBJECTIVES: The goal was to evaluate the incidence and spectrum of platelet function abnormalities in a prospective cohort of individuals referred for bleeding disorder assessments after exclusion of thrombocytopenia and von Willebrand disease. PATIENTS/METHODS: Subjects were healthy controls and patients from a prospective cohort of individuals referred for bleeding disorder assessments after exclusion of thrombocytopenia and von Willebrand disease. LTA was performed by standardized methods using platelet-rich plasma adjusted to 250x10(9) platelets L(-1). Maximal aggregation data were analyzed to determine the likelihood of detecting a platelet function disorder by LTA, and the sensitivity and specificity of LTA for platelet disorders. RESULTS: The incidence of false positive LTA among subjects excluded of having bleeding disorders was similar to healthy controls. Abnormal LTA was more common in subjects with bleeding disorders and the likelihood of a bleeding disorder was significantly increased (odds ratio 32) when maximal aggregation was reduced with two or more agonists. Receiver operator curve analyses indicated that LTA had high specificity and moderate sensitivity for detecting inherited defects in platelet function and that the LTA agonists 1.25 microg mL(-1) collagen, 6 microM epinephrine, 1.6 mM arachidonic acid and 1.0 microM thromboxane analogue U44619 detected most inherited disorders with abnormal LTA. CONCLUSIONS: LTA is valuable for detecting platelet function abnormalities among individuals referred for bleeding problems, particularly when the test indicates abnormal responses to multiple agonists.


Subject(s)
Blood Platelet Disorders/diagnosis , Platelet Function Tests/methods , Platelet Function Tests/standards , 15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5,13-dienoic Acid/pharmacology , Arachidonic Acid/pharmacology , Case-Control Studies , Collagen/pharmacology , Epinephrine/pharmacology , False Positive Reactions , Humans , Nephelometry and Turbidimetry , Platelet Aggregation/drug effects , Prospective Studies , ROC Curve , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...