Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Bioact Mater ; 30: 154-168, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37575877

ABSTRACT

The utilization of biodegradable magnesium (Mg)-based implants for restoration of bone function following trauma represents a transformative approach in orthopaedic application. One such alloy, magnesium-10 weight percent gadolinium (Mg-10Gd), has been specifically developed to address the rapid degradation of Mg while enhancing its mechanical properties to promote bone healing. Previous studies have demonstrated that Mg-10Gd exhibits favorable osseointegration; however, it exhibits distinct ultrastructural adaptation in comparison to conventional implants like titanium (Ti). A crucial aspect that remains unexplored is the impact of Mg-10Gd degradation on the bone microarchitecture. To address this, we employed hierarchical three-dimensional imaging using synchrotron radiation in conjunction with image-based finite element modelling. By using the methods outlined, the vascular porosity, lacunar porosity and the lacunar-canaliculi network (LCN) morphology of bone around Mg-10Gd in comparison to Ti in a rat model from 4 weeks to 20 weeks post-implantation was investigated. Our investigation revealed that within our observation period, the degradation of Mg-10Gd implants was associated with significantly lower (p < 0.05) lacunar density in the surrounding bone, compared to Ti. Remarkably, the LCN morphology and the fluid flow analysis did not significantly differ for both implant types. In summary, a more pronounced lower lacunae distribution rather than their morphological changes was detected in the surrounding bone upon the degradation of Mg-10Gd implants. This implies potential disparities in bone remodelling rates when compared to Ti implants. Our findings shed light on the intricate relationship between Mg-10Gd degradation and bone microarchitecture, contributing to a deeper understanding of the implications for successful osseointegration.

2.
Bioact Mater ; 26: 14-23, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36875051

ABSTRACT

An increasing prevalence of bone-related injuries and aging geriatric populations continue to drive the orthopaedic implant market. A hierarchical analysis of bone remodelling after material implantation is necessary to better understand the relationship between implant and bone. Osteocytes, which are housed and communicate through the lacuno-canalicular network (LCN), are integral to bone health and remodelling processes. Therefore, it is essential to examine the framework of the LCN in response to implant materials or surface treatments. Biodegradable materials offer an alternative solution to permanent implants, which may require revision or removal surgeries. Magnesium alloys have resurfaced as promising materials due to their bone-like properties and safe degradation in vivo. To further tailor their degradation capabilities, surface treatments such as plasma electrolytic oxidation (PEO) have demonstrated to slow degradation. For the first time, the influence of a biodegradable material on the LCN is investigated by means of non-destructive 3D imaging. In this pilot study, we hypothesize noticeable variations in the LCN caused by altered chemical stimuli introduced by the PEO-coating. Utilising synchrotron-based transmission X-ray microscopy, we have characterised morphological LCN differences around uncoated and PEO-coated WE43 screws implanted into sheep bone. Bone specimens were explanted after 4, 8, and 12 weeks and regions near the implant surface were prepared for imaging. Findings from this investigation indicate that the slower degradation of PEO-coated WE43 induces healthier lacunar shapes within the LCN. However, the stimuli perceived by the uncoated material with higher degradation rates induces a greater connected LCN better prepared for bone disturbance.

3.
Regen Biomater ; 10: rbac077, 2023.
Article in English | MEDLINE | ID: mdl-36683753

ABSTRACT

Magnesium (Mg)-based implants are highly attractive for the orthopedic field and may replace titanium (Ti) as support for fracture healing. To determine the implant-bone interaction in different bony regions, we implanted Mg-based alloy ZX00 (Mg < 0.5 Zn < 0.5 Ca, in wt%) and Ti-screws into the distal epiphysis and distal metaphysis of sheep tibiae. The implant degradation and osseointegration were assessed in vivo and ex vivo after 4, 6 and 12 weeks, using a combination of clinical computed tomography, medium-resolution micro computed tomography (µCT) and high-resolution synchrotron radiation µCT (SRµCT). Implant volume loss, gas formation and bone growth were evaluated for both implantation sites and each bone region independently. Additionally, histological analysis of bone growth was performed on embedded hard-tissue samples. We demonstrate that in all cases, the degradation rate of ZX00-implants ranges between 0.23 and 0.75 mm/year. The highest degradation rates were found in the epiphysis. Bone-to-implant contact varied between the time points and bone types for both materials. Mostly, bone-volume-to-total-volume was higher around Ti-implants. However, we found an increased cortical thickness around the ZX00-screws when compared with the Ti-screws. Our results showed the suitability of ZX00-screws for implantation into the distal meta- and epiphysis.

4.
J Clin Sleep Med ; 15(8): 1135-1142, 2019 08 15.
Article in English | MEDLINE | ID: mdl-31482835

ABSTRACT

STUDY OBJECTIVES: The aim was to investigate how the severity of apneas, hypopneas, and related desaturations is associated with obstructive sleep apnea (OSA)-related daytime sleepiness. METHODS: Multiple Sleep Latency Tests and polysomnographic recordings of 362 patients with OSA were retrospectively analyzed and novel diagnostic parameters (eg, obstruction severity and desaturation severity), incorporating severity of apneas, hypopneas, and desaturations, were computed. Conventional statistical analysis and multivariate analyses were utilized to investigate connection of apnea-hypopnea index (AHI), oxygen desaturation index (ODI), conventional hypoxemia parameters, and novel diagnostic parameters with mean daytime sleep latency (MSL). RESULTS: In the whole population, 10% increase in values of desaturation severity (risk ratio = 2.01, P < .001), obstruction severity (risk ratio = 2.18, P < .001) and time below 90% saturation (t90%) (risk ratio = 2.05, P < .001) induced significantly higher risk of having mean daytime sleep latency ≤ 5 minutes compared to 10% increase in AHI (risk ratio = 1.63, P < .05). In severe OSA, desaturation severity had significantly (P < .02) stronger negative correlation (ρ = -.489, P < .001) with mean daytime sleep latency compared to AHI (ρ = -.402, P < 0.001) and ODI (ρ = -.393, P < .001). Based on general regression model, desaturation severity and male sex were the most significant factors predicting daytime sleep latency. CONCLUSIONS: Severity of sleep-related breathing cessations and desaturations is a stronger contributor to daytime sleepiness than AHI or ODI and therefore should be included in the diagnostics and severity assessment of OSA. CITATION: Kainulainen S, Töyräs J, Oksenberg A, Korkalainen H, Sefa S, Kulkas A, Leppänen T. Severity of desaturations reflects OSA-related daytime sleepiness better than AHI. J Clin Sleep Med. 2019;15(8):1135-1142.


Subject(s)
Disorders of Excessive Somnolence/etiology , Hypoxia/etiology , Sleep Apnea, Obstructive/complications , Adult , Aged , Aged, 80 and over , Apnea/blood , Apnea/complications , Disorders of Excessive Somnolence/blood , Female , Humans , Male , Middle Aged , Polysomnography , Retrospective Studies , Severity of Illness Index , Sleep Apnea Syndromes/blood , Sleep Apnea Syndromes/complications
5.
Ultrasound Med Biol ; 45(12): 3186-3198, 2019 12.
Article in English | MEDLINE | ID: mdl-31493954

ABSTRACT

This study investigated the reliability of Achilles and patellar tendon cross-sectional area (CSA) measurement using ultrasound imaging (USI) and magnetic resonance imaging (MRI). Fifteen healthy adults were imaged twice on two occasions, interrupted by a tendon loading protocol. Tendon CSA segmentations were conducted by an experienced and an inexperienced rater blinded to information regarding subject, session and loading status. USI provided good test-retest reliability (intra-class correlation coefficient [ICC] 2,1 > 0.85, standard error of measurement [SEM] 5%-6%), while with MRI it was excellent (ICC 2,1 > 0.92, SEM 4%) for the experienced rater. This study suggests that MRI provides superior reliability for tendon CSA measurements compared with USI. However, the difference in reliability between the methods was small, and the results were inconclusive regarding objectivity and sensitivity to change when assessed based on the effect of loading. We concluded that both methods can be used for reliable CSA measurements of the Achilles and patellar tendons when using a highly standardized measurement protocol and when conducted by an experienced rater.


Subject(s)
Achilles Tendon/anatomy & histology , Magnetic Resonance Imaging/methods , Patellar Ligament/anatomy & histology , Ultrasonography/methods , Adult , Female , Humans , Male , Reference Values , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...