Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Res ; 218: 114925, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36462691

ABSTRACT

In this research, Hydroxyethyl cellulose - graphene oxide HEC-GO and HEC-GO/Fe-Zn mole ratio (2:1) nanocomposite as adsorbents were fabricated by crosslinking ethylene glycol dimethacrylate (EGDMA) to study the thermodynamic, kinetic and isotherm of doxycycline antibiotic adsorption. The morphology and structure of the adsorbents were analyzed by Fourier transform infrared spectroscopy (FT-IR), Field Emission Scanning Electron Microscopy with Energy Dispersive X-Ray Spectroscopy (FE-SEM- EDX), and Transmission electron microscopy (TEM). The adsorption behavior of doxycycline (DOX) was studied with different parameters including doxycycline concentration, pH, the dose of adsorbent (HEC-GO and HEC-GO/Fe-Zn, mole ratio (2:1)), contact time, and temperature. The optimal conditions for the removal of DOX are pH = 3.0, contact time 100 min, and 20 min for HEC-GO and HEC-GO/Fe-Zn mole ratio (2:1). The removal percentage for HEC-GO and HEC-GO/Fe-Zn mole ratio (2:1) was 97% and 95.5%, respectively. Equilibrium adsorption isotherms such as the Langmuir, Freundlich, and Temkin models were analyzed according to the experimental data. Also, four adsorption kinetics were investigated for removing DOX. The Langmuir isotherm and pseudo-second-order kinetic models provided the best fit for experimental data for HEC-GO and HEC-GO/Fe-Zn mole ratio (2:1). Thermodynamic data showed that negative values of Gibbs free energy (ΔG°) and the negative value of enthalpy (ΔH°) of the adsorption process for adsorbents. It means that DOX removal was a spontaneous and exothermic reaction.


Subject(s)
Nanoparticles , Water Pollutants, Chemical , Doxycycline , Spectroscopy, Fourier Transform Infrared , Thermodynamics , Cellulose , Zinc , Adsorption , Kinetics , Water Pollutants, Chemical/analysis , Hydrogen-Ion Concentration
2.
Chemosphere ; 312(Pt 1): 137184, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36400191

ABSTRACT

Tetracycline (TC) as an antibiotic with high consumption causes the spread of contamination in an aqueous solution. In recent decades, antibiotics are the main cause of hindering the growth of microorganisms. Also, they are one of the important groups of pharmaceuticals with extensive usage in human and veterinary medicine. In the first work of its kind, we used a suitable adsorbent of biodegradable hydroxyethylcellulose (HEC) with graphene oxide (GO) by crosslinking ethylene glycol dimethacrylate (EGDMA) and the Fe/Zn with mole ratio 1:1 bimetallic nanoparticles with HEC-GO support. The materials were identified using FTIR, FE-SEM, EDX, TEM, and TG- DSC analyses. The factors affecting the adsorption process (contact time, initial concentration of TC, solution pH, adsorbent dosage, and reaction temperature) were evaluated in a series of batch systems. The adsorption data showed that the high adsorption capacity was obtained on the HEC-GO and HEC-GO/Fe-Zn (mole ratio 1:1) nanocomposites at pH 3. Also, the contact time as the main factor affecting the adsorption process by adsorbents was investigated and the best contact time was 100 and 20 min. The TC removal percentages of both adsorbents were 85% and 95% for HEC-GO and HEC-GO/Fe-Zn, respectively. The maximum adsorption capacity for TC was evaluated by the isotherm models. The experimental data fitted well with the Langmuir model. In addition, pseudo-first-order, pseudo-second-order, intraparticle diffusion, and the Elovich models were applied to kinetic data. The data indicated that TC adsorption on HEC-GO and HEC-GO/Fe-Zn (mole ratio 1:1) followed the pseudo-second-order kinetic model. The thermodynamic parameters implied that the adsorption process was spontaneous and exothermic. Nano-biocomposite (HEC-GO/Fe-Zn) can be used as an adsorbent to remove water pollutants.


Subject(s)
Graphite , Nanoparticles , Water Pollutants, Chemical , Humans , Water Pollutants, Chemical/analysis , Graphite/chemistry , Adsorption , Tetracycline/chemistry , Anti-Bacterial Agents/chemistry , Water , Kinetics , Zinc , Hydrogen-Ion Concentration
SELECTION OF CITATIONS
SEARCH DETAIL
...