1.
ISRN Dent ; 2011: 102329, 2011.
Article in English | MEDLINE | ID: mdl-21991454

ABSTRACT

Purpose. To analyze the stress distribution in an endodontically treated maxillary central incisor restored with various post-core systems and assess the benefit of ferrule using finite element analysis. Material and Methods. Twelve models with metal ceramic crown were created based on the combination of three types of post-core systems (titanium post-composite resin core, nickel-chromium post-core, and fiber reinforced composite resin post-composite resin core), two varieties of posts (tapered, parallel), and with or without ferrule. 100 N load was applied in three directions and the von Mises stress was compared. Results. Ferrule made no difference in stress distribution for the titanium and nickel-chromium posts, though it showed some stress reduction in fiber-reinforced composite resin posts. Nickel-chromium cast post-core transmitted the least amount of stresses to the dentin despite producing the maximum stress. Conclusion. Incorporation of ferrule offered some degree of stress reduction in nonmetal post, and it increased the stresses within cervical dentin.