Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
2.
Am J Ophthalmol Case Rep ; 26: 101531, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35509285

ABSTRACT

Purpose: To report convergence insufficiency in a patient with Parkinson's' disease stimulated by turning on the deep brain stimulator. Observations: 72-year-old male with Parkinson's disease and hypertension presenting for the evaluation of blurry vision at near and mid distance that started after activation of an implanted Deep brain stimulator.Baseline ophthalmologic evaluation prior to deep brain stimulator implantation surgery and with the deep brain stimulator turned off demonstrated a full motility, centered eyes for distance and near and a best corrected visual acuity of 20/20, normal pupil exam, confrontational visual fields and dilated fundus exam. Following this examination, the Deep brain stimulator was turned on and re-evaluation few minutes later demonstrated the same findings except for a 6-prism diopter exotropia at near consistent with convergence insufficiency.Following our evaluation a set of +3 diopters base-in prisms were added to near glasses with total relief of symptoms. The patient did not require surgical adjustment of the deep brain stimulator leads. Conclusions and importance: Given the therapeutic effects of deep brain stimulation on convergence insufficiency reported in several studies, in addition to the influence of deep brain stimulation as Parkinson's Disease treatment in areas possibly associated with vergence control, convergence insufficiency secondary to deep brain stimulation does not seem very unlikely, although not often reported. Further studies are needed to optimize deep brain stimulation surgery to maximize benefits and limit adverse events, as well as being aware of convergence insufficiency as a possible cause for visual disturbance.

3.
J Curr Glaucoma Pract ; 16(3): 152-157, 2022.
Article in English | MEDLINE | ID: mdl-36793263

ABSTRACT

Aim: To report the efficacy of the revision of failed ab interno canaloplasty with micro-invasive suture trabeculotomy (MIST) over a follow-up period of 24 months. Materials and methods: A retrospective analysis was performed on 23 eyes with open-angle glaucoma (OAG), on whom an ab interno canaloplasty revision with MIST was performed for glaucoma progression. The primary outcome was the proportion of eyes with a significant intraocular pressure (IOP) reduction at 12 months post trabeculotomy, defined as an IOP ≤ 18 mm Hg or ≥20% reduction in IOP without any secondary intervention (SI), and with the same or fewer number of glaucoma medications (NGM). All parameters, including best corrected visual acuity (BCVA), IOP, NGM, and SI, were evaluated at 1, 6, 12, 18, and 24 months. Results: At 12 months, eight out of 23 eyes (36.4%) achieved complete success, maintained in six eyes (27.3%) at 24 months. A significantly lower mean IOP was recorded at all visits [14.3 ± 4.0 mm Hg at 24 months vs 23.1 ± 6.8 mm Hg at baseline (BL)] with a percent IOP change of up to 27.3% at 24 months postoperatively. NGM and BCVA did not significantly decrease from BL. A total of 11 eyes (47.8%) needed an SI throughout the follow-up period. Conclusion: Ab interno trabeculotomy in patients with failed canaloplasty was not shown to be effective in providing a satisfactory control of IOP in OAG patients, possibly due to the small suture gauge used in the initial canaloplasty. Clinical significance: Further research is needed to optimize the surgical outcome. How to cite this article: Seif R, Jalbout NDE, Sadaka A, et al. Size Matters: Ab Interno Canaloplasty Revision with Suture Trabeculotomy. J Curr Glaucoma Pract 2022;16(3):152-157.

4.
Semin Ophthalmol ; 37(2): 265-267, 2022 Feb 17.
Article in English | MEDLINE | ID: mdl-34779343

ABSTRACT

OBJECTIVE: To study the success rate of strabismus surgery in patients with varying levels of severity of cerebral palsy (CP). DESIGN: A retrospective study was conducted. PARTICIPANTS: Sixty-four patients with varying severity of CP were included. METHODS: All patients with different CP severity levels underwent strabismus surgery. Success was defined as any postoperative heterotropia outcome of less than 10 prism diopters in primary position. Statistical analysis was conducted using chi-square. RESULTS: The mean age at the time of strabismus surgery was 3.1 years, and the mean follow-up was 6.0 years. The most common types of strabismus were infantile-onset exotropia in 36 patients (56%) and infantile-onset esotropia in 28 patients (44%). Surgical success was found to be better in patients with mild GMFCS (GMFCS levels 1-2) with 68% having less than 10 PD of eso or exotropia in primary gaze, as compared to patients with severe GMFCS (GMFCS levels 3-5) (38% with 10 PD of heterotropia) (P < .05; χ2). Refractive errors included myopia (27.5% in mild cases and 41.6% in severe), emmetropia (10% in mild and 8.3% in severe) and hyperopia (62.5% in mild and 50% in severe). Around 50% of the mild cases had absent binocular fusion compared to 66.6% of those with severe CP. Amblyopia was found in 62.5% of the mild cases and 54.1% of the severe cases. Nystagmus was present in 25% with mild disease and 29.1% of those with severe disease. CONCLUSION: Restoration of good ocular alignment in patients with CP is achievable in more than half of the cases. Patients with more severe CP have poorer outcomes than those with milder palsies. There appears to be no difference in outcomes between the different types of strabismus.


Subject(s)
Cerebral Palsy , Esotropia , Exotropia , Strabismus , Cerebral Palsy/complications , Child , Esotropia/etiology , Esotropia/surgery , Exotropia/surgery , Follow-Up Studies , Humans , Oculomotor Muscles/surgery , Ophthalmologic Surgical Procedures , Retrospective Studies , Strabismus/etiology , Strabismus/surgery , Vision, Binocular
5.
Case Rep Ophthalmol Med ; 2021: 3671951, 2021.
Article in English | MEDLINE | ID: mdl-33510921

ABSTRACT

Digital marking systems have been shown to be more accurate at positioning toric intraocular lenses and hence providing better visual outcomes. Patients with cyclodeviation and concomitant astigmatism undergoing toric intraocular lens placement present an extra challenge. We present a case of a patient with high astigmatism and a preexisting superior oblique palsy where using the Verion™ digital marking system proved to be an extremely valuable tool. We suggest that using this technology is especially helpful in patients with preexisting cyclodeviation and compensatory head tilt.

SELECTION OF CITATIONS
SEARCH DETAIL
...