Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 175
Filter
1.
J Transl Med ; 20(1): 121, 2022 03 14.
Article in English | MEDLINE | ID: mdl-35287672

ABSTRACT

BACKGROUND: Safety, tolerability and efficacy of granulocyte colony-stimulating factor (G-CSF) for mobilization of hematopoietic stem and progenitor cells (HSPCs) from healthy donors have been conclusively demonstrated. This explicitly includes, albeit for smaller cohorts and shorter observation periods, biosimilar G-CSFs. HSPC donation is non-remunerated, its sole reward being "warm glow", hence harm to donors must be avoided with maximal certitude. To ascertain, therefore, long-term physical and mental health effects of HSPC donation, a cohort of G-CSF mobilized donors was followed longitudinally. METHODS: We enrolled 245 healthy volunteers in this bi-centric long-term surveillance study. 244 healthy volunteers began mobilization with twice-daily Sandoz biosimilar filgrastim and 242 underwent apheresis after G-CSF mobilization. Physical and mental health were followed up over a period of 5-years using the validated SF-12 health questionnaire. RESULTS: Baseline physical and mental health of HSPC donors was markedly better than in a healthy reference population matched for ethnicity, sex and age. Physical, but not mental health was sharply diminished at the time of apheresis, likely due to side effects of biosimilar G-CSF, however had returned to pre-apheresis values by the next follow-up appointment after 6 months. Physical and mental health slightly deteriorated over time with kinetics reflecting the known effects of aging. Hence, superior physical and mental health compared to the general healthy non-donor population was maintained over time. CONCLUSIONS: HSPC donors are of better overall physical and mental health than the average healthy non-donor. Superior well-being is maintained over time, supporting the favorable risk-benefit assessment of volunteer HSPC donation. Trial registration National Clinical Trial NCT01766934.


Subject(s)
Hematopoietic Stem Cell Mobilization , Mental Health , Granulocyte Colony-Stimulating Factor/pharmacology , Healthy Volunteers , Hematopoietic Stem Cells , Humans
2.
Eur J Med Res ; 25(1): 12, 2020 Apr 07.
Article in English | MEDLINE | ID: mdl-32264953

ABSTRACT

BACKGROUND: Aim of the present study is the evaluation of ultrasound as a physical method for virus inactivation in human plasma products prior to transfusion. Our study is focused on achieving a high level of virus inactivation simultaneously leaving blood products unaltered, measured by the level of degradation of coagulation factors, especially in third world countries where virus contamination of blood products poses a major problem. Virus inactivation plays an important role, especially in the light of newly discovered or unknown viruses, which cannot be safely excluded via prior testing. METHODS: Taking into account the necessary protection of the relevant coagulation activity for plasma, the basis for a sterile virus inactivation under shielding gas insufflation was developed for future practical use. Influence of frequency and power density in the range of soft and hard cavitation on the inactivation of transfusion-relevant model viruses for Hepatitis-(BVDV = bovine diarrhea virus), for Herpes-(SFV = Semliki Forest virus, PRV = pseudorabies virus) and Parvovirus B19 (PPV = porcine parvovirus) were examined. Coagulation activity was examined via standard time parameters to minimize reduction of functionality of coagulation proteins. A fragmentation of coagulation proteins via ultrasound was ruled out via gel electrophoresis. The resulting virus titer was examined using end point titration. RESULTS: Through CO2 shielding gas insufflation-to avoid radical emergence effects-the coagulation activity was less affected and the time window for virus inactivation substantially widened. In case of the non-lipidated model virus (AdV-luc = luciferase expressing adenoviral vector), the complete destruction of the virus capsid through hard cavitation was proven via scanning electron microscopy (SEM). This can be traced back to microjets and shockwaves occurring in hard cavitation. The degree of inactivation seems to depend on size and compactness of the type of viruses. Using our pre-tested and subsequently chosen process parameters with the exception of the small PPV, all model viruses were successfully inactivated and reduced by up to log 3 factor. For a broad clinical usage, protection of the coagulation activities may require further optimization. CONCLUSIONS: Building upon the information gained, an optimum inactivation can be reached via raising of power density up to 1200 W and simultaneous lowering of frequency down to 27 kHz. In addition, the combination of the two physical methods UV treatment and ultrasound may yield optimum results without the need of substance removal after the procedure.


Subject(s)
Plasma/virology , Sonication , Virus Inactivation , Viruses/pathogenicity , Animals , Humans , Swine , Virus Diseases
3.
Vox Sang ; 112(8): 713-722, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28960367

ABSTRACT

BACKGROUND AND OBJECTIVES: Interventions to prevent and detect bacterial contamination of platelet concentrates (PCs) have reduced, but not eliminated the sepsis risk. Standardized bacterial strains are needed to validate detection and pathogen reduction technologies in PCs. Following the establishment of the First International Reference Repository of Platelet Transfusion-Relevant Bacterial Reference Strains (the 'repository'), the World Health Organization (WHO) Expert Committee on Biological Standardisation (ECBS) endorsed further repository expansion. MATERIALS AND METHODS: Sixteen bacterial strains, including the four repository strains, were distributed from the Paul-Ehrlich-Institut (PEI) to 14 laboratories in 10 countries for enumeration, identification and growth measurement on days 2, 4 and 7 after low spiking levels [10-25 colony-forming units (CFU)/PC bag]. Spore-forming (Bacillus cereusPEI-B-P-07-S, Bacillus thuringiensisPEI-B-P-57-S), Gram-negative (Enterobacter cloacaePEI-B-P-43, Morganella morganiiPEI-B-P-74, PEI-B-P-91, Proteus mirabilisPEI-B-P-55, Pseudomonas fluorescensPEI-B-P-77, Salmonella choleraesuisPEI-B-P-78, Serratia marcescensPEI-B-P-56) and Gram-positive (Staphylococcus aureusPEI-B-P-63, Streptococcus dysgalactiaePEI-B-P-71, Streptococcus bovisPEI-B-P-61) strains were evaluated. RESULTS: Bacterial viability was conserved after transport to the participating laboratories with one exception (M. morganiiPEI-B-P-74). All other strains showed moderate-to-excellent growth. Bacillus cereus, B. thuringiensis, E. coli, K. pneumoniae, P. fluorescens, S. marcescens, S. aureus and S. dysgalactiae grew to >106 CFU/ml by day 2. Enterobacter cloacae, P. mirabilis, S. epidermidis, S. bovis and S. pyogenes achieved >106 CFU/ml at day 4. Growth of S. choleraesuis was lower and highly variable. CONCLUSION: The WHO ECBS approved all bacterial strains (except M. morganiiPEI-B-P-74 and S. choleraesuisPEI-B-P-78) for repository enlargement. The strains were stable, suitable for spiking with low CFU numbers, and proliferation was independent of the PC donor.


Subject(s)
Blood Platelets/microbiology , Blood Safety/standards , Platelet Transfusion , Biological Specimen Banks , Escherichia coli/growth & development , Humans , Klebsiella pneumoniae/growth & development , Reference Standards , Staphylococcus aureus/growth & development , Staphylococcus epidermidis/growth & development , World Health Organization
4.
Vox Sang ; 111(4): 391-398, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27509167

ABSTRACT

BACKGROUND AND OBJECTIVES: Patient Blood Management (PBM) in Europe is a working group of the European Blood Alliance with the initial objective to identify the starting position of the participating hospitals regarding PBM for benchmarking purposes, and to derive good practices in PBM from the experience and expertise in the participating teams with the further aim of implementing and strengthening these practices in the participating hospitals. METHODS: We conducted two surveys in seven university hospitals in Europe: Survey on top indications for red blood cell use regarding usage of red blood cells during 1 week and Survey on PBM organization and activities. RESULTS: A total of 3320 units of red blood cells were transfused in 1 week at the seven hospitals. Overall, 61% of red cell units were transfused to medical patients and 36% to surgical patients, although there was much variation between hospitals. The organization and activities of PBM in the seven hospitals were variable, but there was a common focus on optimizing the treatment of bleeding patients, monitoring the use of blood components and treatment of preoperative anaemia. CONCLUSION: Although the seven hospitals provide a similar range of clinical services, there was variation in transfusion rates between them. Further, there was variable implementation of PBM activities and monitoring of transfusion practice. These findings provide a baseline to develop joint action plans to further implement and strengthen PBM across a number of hospitals in Europe.


Subject(s)
Hospitals, University , Anemia/therapy , Blood Preservation , Blood Transfusion/standards , Blood Transfusion/statistics & numerical data , Europe , Health Care Surveys , Humans
5.
Vox Sang ; 110(4): 329-35, 2016 May.
Article in English | MEDLINE | ID: mdl-26766162

ABSTRACT

BACKGROUND: Ebola virus disease is a public health emergency of international concern, and enormous efforts are being made in the development of vaccines and therapies. Ebola virus convalescent plasma is a promising anti-infective treatment of Ebola virus disease. Therefore, we developed and implemented a pathogen-reduced Ebola virus convalescent plasma concept in accordance with national, European and global regulatory framework. MATERIALS AND METHODS: Ebola virus convalescent plasma manufacture and distribution was managed by a collection centre, two medical centres and an expert group from the European Blood Alliance. Ebola virus convalescent plasma was collected twice with an interval of 61 days from a donor recovering from Ebola virus disease in Germany. After pathogen reduction, the plasma was analysed for Ebola virus-specific immunoglobulin G (IgG) antibodies and its Ebola virus neutralizing activity. RESULTS: Convalescent plasma could be collected without adverse events. Anti-Ebola virus IgG titres and Ebola-specific neutralizing antibodies in convalescent plasma were only slightly reduced after pathogen reduction treatment with S59 amotosalen/UVA. A patient in Italy with Ebola virus disease was treated with convalescent plasma without apparent adverse effects. DISCUSSION: As proof of principle, we describe a concept and practical implementation of pathogen-reduced Ebola virus convalescent plasma manufacture, quality control and its clinical application to an Ebola virus disease patient.


Subject(s)
Antibodies, Neutralizing/isolation & purification , Ebolavirus/immunology , Hemorrhagic Fever, Ebola/prevention & control , Immunoglobulin G/isolation & purification , Adult , Antibodies, Neutralizing/immunology , Antibodies, Neutralizing/therapeutic use , Blood Donors , Convalescence , Furocoumarins/pharmacology , Germany , Humans , Immunoglobulin G/immunology , Immunoglobulin G/therapeutic use , Male , Middle Aged , Photosensitizing Agents/pharmacology , Quality Control , Ultraviolet Rays , Virus Inactivation/drug effects , Virus Inactivation/radiation effects
7.
Vox Sang ; 109(4): 387-93, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25951789

ABSTRACT

BACKGROUND: The safety and clinical efficacy of adoptive transfer of prospectively isolated antigen-specific T cells are well established. Several competing selection methods are available, one of which is based on immunomagnetic enrichment of T cells secreting IFNγ after incubation with the relevant antigen. The proprietary, GMP-conforming selection technology, called 'cytokine capture system' (CCS) is established in many laboratories for the CliniMACS Plus system. It is robust and efficient, but labour-intensive and incompatible with a single-shift working schedule. An automatic immunomagnetic cell processing system, CliniMACS Prodigy ('Prodigy'), including a protocol for fully automatic CCS execution was recently released. MATERIAL AND METHODS: Feasibility of clinical-scale CMV-specific T-cell selection using Prodigy was evaluated using leukoapheresis products from five healthy CMV sero-positive volunteers. Clinical reagents and consumables were used throughout. RESULTS: The process required no operator input beyond set-up and QC-sample collection, that is, feasibility was given. An IFNγ-secreting target T-cell population was detectable after stimulation, and >2 log-scale relative depletion of not CMV-reactive T cells in the target population was achieved. Purity, that is the frequency of CMV-reactive T cells among all CD3(+) cells ranged between 64 and 93%. CONCLUSION: The CCS protocol on Prodigy is unrestrictedly functional. It runs fully automatically beyond set-up and thus markedly reduces labour. The quality of the products generated is similar to products generated with CliniMACS Plus. The automatic system is thus suitable for routine clinical application.


Subject(s)
Flow Cytometry/methods , Lymphocyte Activation , T-Lymphocytes/immunology , Cytokines/genetics , Cytokines/metabolism , Flow Cytometry/instrumentation , Humans
8.
Vox Sang ; 109(2): 114-21, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25899479

ABSTRACT

BACKGROUND: Mandatory screening of blood donations for hepatitis B and hepatitis C viruses and human immunodeficiency viruses 1 and 2 requires assays with exceptional sensitivity and specificity. This study reports the results from a direct head-to-head comparison of the Elecsys HBsAG II, Elecsys Anti-HBc, Elecsys Anti-HCV II and Elecsys HIV combi PT immunoassays with the respective ABBOTT PRISM/Architect instrument immunoassays in a multicentre blood bank evaluation study. STUDY DESIGN AND METHODS: Assay validation was performed in the blood screening laboratories of four blood bank centres in Austria, Germany, Spain and Thailand, where both first-time donor samples (approximately 6000 donors) and repeat donor samples (approximately 14,000 donors) were screened. RESULTS: Of all screened donor samples, 93 (0.46%) were confirmed to be positive using assays from both manufacturers. The specificity of all immunoassays was >99.5% and was comparable between first-time and multiple-time donors. A direct comparison between the assays from Roche and ABBOTT according to Bland and Altman analysis demonstrated equivalent quality. CONCLUSIONS: These results suggest that the Elecsys immunoassays for HBV, HCV and HIV infection, with a comparative sensitivity of 100% and a specificity exceeding the common technical specification threshold of >99.5%, meet the stringent performance criteria stipulated for blood donor screening for these infectious agents. Significant differences in the specificity between first-time and repeat donors were not detectable.


Subject(s)
HIV Infections/blood , Hepatitis B/blood , Hepatitis C/blood , Immunoassay/methods , Serologic Tests/methods , HIV Antibodies/blood , HIV Antibodies/immunology , Hepatitis B Surface Antigens/blood , Hepatitis B Surface Antigens/immunology , Hepatitis C Antibodies/blood , Hepatitis C Antibodies/immunology , Humans
9.
J Thromb Haemost ; 12(11): 1861-73, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25224783

ABSTRACT

BACKGROUND: FVIII neutralizing antibodies are the main complication of substitution therapy in hemophilia A (HA); auto-antibodies against FVIII causing acquired HA can also occur. Treatment of inhibitor patients remains challenging because prophylactic treatment with existing FVIII bypassing agents, all based on constitutively active coagulation factors, is difficult due to their short half-life. OBJECTIVES: To generate zymogenic FIX variants with FVIII-independent activity for gene- and protein-based therapy for HA. METHODS: Modifications were introduced into FIX based on current knowledge of FIX structure and FVIII-independent function followed by random screening. Activity, thrombin generation and FX activation by FIX mutants were characterized in the presence and absence of FVIII. Phenotype correction of promising candidates was assessed by the tail-clip assay in FVIII-knockout mice. RESULTS: About 1600 clones were screened and three mutations (L6F, S102N and E185D) identified, which improved FVIII-independent activity in combination with our previously described variant FIX-ITV. By systematic combination of all mutations, six FIX mutants with the desired bypassing activity were designed. Candidate mutants FIX-IDAV and FIX-FIAV demonstrated the most efficient thrombin generation in FVIII-deficient plasma and had considerably increased activities towards FX in the absence of FVIII, in that they showed an up to 5-fold increase in catalytic efficiency. Expression of FIX-IDAV in FVIII knockout mice reduced blood loss after the tail-clip assay, even in the presence of neutralizing FVIII antibodies. CONCLUSION: Activatable bioengineered FIX molecules (as opposed to pre-activated coagulation factors) with FVIII-independent activity might be a promising tool for improving HA treatment, especially for patients with inhibitors.


Subject(s)
Factor IX/genetics , Factor VIII/metabolism , Genetic Therapy/methods , Hemophilia A/therapy , Hemostasis , Mutation , Animals , Dependovirus/genetics , Disease Models, Animal , Factor IX/biosynthesis , Factor VIII/biosynthesis , Factor VIII/genetics , Factor Xa/metabolism , Gene Transfer Techniques , Genetic Vectors , HEK293 Cells , Hemophilia A/blood , Hemophilia A/diagnosis , Humans , Liver/metabolism , Mice, Inbred C57BL , Mice, Knockout , Models, Molecular , Protein Conformation , Structure-Activity Relationship , Thrombin/metabolism , Time Factors , Transfection
10.
Bone Marrow Transplant ; 49(11): 1419-25, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25089595

ABSTRACT

To minimize donor risk and maintain public support, volunteer donor stem cell donation, whether by mobilized leukapheresis or marrow aspiration, requires careful donor eligibility assessment. Many contraindications to stem cell donation exist, yet analyses of donor deferral rates are not available. In a 36-month series encompassing 2493 potential stem cell donors, we analyzed frequencies and reasons for deferrals. All were presumed eligible by their registries because of previously submitted structured health questionnaire and formal telephone interviews. After assessment by our center's physicians, 3.3% of donors proved ineligible, but 5.6% more were eligible for only one of the collection methods. Higher deferral rates were associated with female sex, increasing age and mobilized stem cell donation vs marrow. Exclusion criteria were identified with approximately similar frequency by medical history, physical examination and laboratory testing. Reasons for deferrals almost exclusively served to protect donor safety; the rare recipient-directed safety concerns could be, and often were, overridden in agreement with the transplant center. As formal analyses have shown, with careful assessment, stem cell donation is acceptably safe, but the plethora of deferral reasons mandate that only physicians with specific experience should evaluate stem cell donors, that is, this task should not be delegated to paramedical personnel.


Subject(s)
Donor Selection/methods , Living Donors , Registries , Stem Cells , Unrelated Donors , Adolescent , Adult , Age Factors , Female , Humans , Male , Middle Aged , Sex Factors
12.
J Thromb Haemost ; 12(6): 932-42, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24679056

ABSTRACT

BACKGROUND: Oral gene delivery of non-viral vectors is an attractive strategy to achieve transgene expression. Although expected efficacy from non-viral delivery systems is relatively low, repeated vector administration is possible and may help to obtain durable transgene expression in a therapeutic range. OBJECTIVES: To test the principle feasibility of using factor (F) IX variants with improved function combined with an optimized oral delivery system in hemophilia B (HB) mice. METHODS: FIX modifications were introduced by site-directed mutagenesis into plasmid- or minicircle-based expression cassettes. Vectors were formulated as chitosan nanoparticles for oral delivery to HB mice. Protection of vector DNA in nanoparticle constructs and transfection efficiency were characterized. HB mice received eGFP-formulated chitosan nanoparticles to confirm gene transfer in vivo. FIX expression, phenotype correction and the potential of nanoparticles to induce immunotolerance (ITI) against exogenous FIX were evaluated after repeated oral administration. RESULTS: Transfection of HEK 293T cells or livers of FIX-knockout mice with nanoparticles resulted in GFP or functional FIX expression. Oral administration of FIX mutants resulted in exclusive FIX expression in the small intestine, as confirmed by RT-PCR and fluorescence staining. HB mice demonstrated transient FIX expression reaching > 14% of normal activity and partial phenotype correction after oral delivery of FIX mutants with high specific activity and improved tissue release. CONCLUSION: The feasibility of oral, non-viral delivery of FIX was established and improved by bioengineered FIX proteins and optimized vectors. Thus, these data might point the way for development of a clinically applicable oral gene transfer strategy for hemophilia B.


Subject(s)
Chitosan/administration & dosage , Factor IX/administration & dosage , Factor IX/genetics , Genetic Therapy/methods , Hemophilia B/therapy , Mutation , Administration, Oral , Animals , Disease Models, Animal , Factor IX/biosynthesis , Feasibility Studies , Genotype , HEK293 Cells , Hemophilia B/blood , Hemophilia B/genetics , Hemostasis , Humans , Intestine, Small/metabolism , Liver/metabolism , Mice, Inbred C57BL , Mice, Knockout , Mutagenesis, Site-Directed , Nanoparticles , Phenotype , Time Factors , Transfection
14.
Tissue Antigens ; 83(4): 295-6, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24456416

ABSTRACT

HLA-B*44:101 and HLA-B*57:48 are characterized by amino acid substitutions in the alpha 2 domain.


Subject(s)
Alleles , Databases, Nucleic Acid , HLA-B Antigens/genetics , Base Sequence , Humans , Molecular Sequence Data , Protein Structure, Tertiary , White People
15.
Bone Marrow Transplant ; 49(3): 338-48, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24185589

ABSTRACT

Bone marrow (BM) remains a common source for hematopoietic SCT. Due to the transcutaneous approach, contamination with skin bacteria is common. The delay between harvest and transfusion can be considerable, potentially allowing for bacterial proliferation. The optimal transportation temperature, specifically with respect to bacterial growth and consequences thereof for hematopoietic quality, remain undefined. For 72 h, 66 individual BM samples, non-spiked/spiked with different bacteria, stored at 20-24 °C room temperature (RT) or 3-5 °C (cold), were serially analyzed for hematopoietic quality and microbial burden. Under most conditions, hematopoietic quality of BM was equal or better at RT: Typical BM contaminants (P. acnes and S. epidermidis) and E. coli were killed or bacterial proliferation was arrested at RT; hematopoietic quality was not impacted by the contamination. However, several pathogenic bacteria not typically found in BM (S. aureus and K. pneumoniae) proliferated dramatically at RT and impaired hematopoietic quality. Bacterial proliferation was arrested in the cold. The overwhelming majority of BM samples, that is, those that are sterile or contaminated only with skin commensals, will benefit from transportation at RT. Those bacteria that proliferate and perturb hematopoietic quality are not typically found in BM. Our data support recommendations for RT transportation and storage of BM.


Subject(s)
Bone Marrow/pathology , Specimen Handling/methods , Temperature , Anti-Bacterial Agents/therapeutic use , Bone Marrow/microbiology , Escherichia coli , Hematopoiesis , Hematopoietic Stem Cell Transplantation , Humans , Klebsiella pneumoniae , Propionibacterium acnes , Skin/microbiology , Staphylococcus aureus , Staphylococcus epidermidis , Stem Cells , Time Factors , Tissue Preservation/methods
16.
Hamostaseologie ; 33 Suppl 1: S64-8, 2013.
Article in English | MEDLINE | ID: mdl-24344447

ABSTRACT

Thrombotic thrombocytopenic purpura (TTP), immune thrombocytopenia (ITP) and acquired haemophilia are very rare haemorrhagic disorders (1) associated with surgery, hospitalization (2) and death being reported (3). Despite the rapid development of interventional techniques, therapeutic options for patients with these illnesses remain limited. We suppose that depression and anxiety disorders appear more frequently than in the normal population in patients with rare haemorrhagic disorders.


Subject(s)
Anxiety/epidemiology , Depression/epidemiology , Hemorrhagic Disorders/epidemiology , Adult , Aged , Aged, 80 and over , Causality , Cohort Studies , Comorbidity , Female , Germany/epidemiology , Humans , Incidence , Male , Middle Aged , Prospective Studies , Rare Diseases/epidemiology , Risk Factors , Young Adult
18.
Vox Sang ; 105(1): 47-53, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23384315

ABSTRACT

BACKGROUND AND OBJECTIVES: Therapeutic leucodepletion plays an established role in the initial treatment of patients with acute myeloid leukaemia (AML) and possibly other leukaemias presenting with leucostasis. Recently, a new leucodepletion technology, Spectra Optia IDL, has become available that differs from its predecessor, COBE Spectra MNC, by a variety of electronic supports, including by electronic adjustment of buffy coat positioning at the collection port. Given the paucity of patients in need of leucodepletions and marked differences in clinical presentation as well as blast properties (e.g. size, density), formal clinical trials comparing leucodepletion technologies have never been executed. MATERIALS AND METHODS: Here, we present aggregate data from eight leucodepletions performed in AML patients with clinical signs of leucostasis between 11/2011 and 07/2012 with the new device and compare the apheresis outcomes with those from fifteen leucodepletions performed with the old technology between 06/2010 and 10/2011. RESULTS: Patients did not differ with respect to epidemiological data. Pre-apheresis leucocyte count (WBC) was significantly higher in Spectra Optia IDL patients. Tolerability was excellent with both devices. Basic apheresis denominators such as duration, processed volume, inlet pump rate, ACD-A consumption and product volume were very similar. A negative correlation between pre-apheresis WBC and collection efficiency was noted. Mean collection efficiency for leucocytes with Spectra Optia IDL (47·3%) was similar to that with COBE Spectra MNC (50·5%). Platelet attrition was similar with both devices, approximately 30%. CONCLUSION: The novel, electronically guided leukapheresis system is suitable for leucodepletion.


Subject(s)
Leukemia, Myeloid, Acute/therapy , Leukocyte Reduction Procedures/instrumentation , Leukocyte Reduction Procedures/methods , Leukocytosis/therapy , Leukostasis/therapy , Aged , Female , Humans , Leukemia, Myeloid, Acute/blood , Leukocyte Count , Leukocytosis/blood , Leukostasis/blood , Male , Middle Aged
19.
Vox Sang ; 104(1): 46-54, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22827736

ABSTRACT

BACKGROUND AND OBJECTIVES: G-CSF-mobilized peripheral blood stem cells have long replaced marrow as the major source for allogeneic transplants. Conclusive evidence questioning the long-term safety of G-CSF for donors has not been provided, but the cumulative number of followed donors remains insufficient to rule out rare adverse events. A long-term active follow-up study of G-CSF-mobilized healthy volunteer donors was therefore performed. PATIENTS AND METHODS: Two hundred and three successive donors were evaluated pre-apheresis, subjected to G-CSF-mobilization/apheresis, and actively followed for 5 years by the same physicians and laboratories. Follow-up laboratory work included standard biochemical/haematological tests and T-cell phenotyping. RESULTS: Donor epidemiology was typical for reported stem cell donor cohorts. Acute adverse effects of G-CSF and apheresis were mild and transient, consistent with the previous reports. Mean circulating CD34(+) cells after nine doses of G-CSF were 124 per µl. Other biochemical/haematological parameters were also altered, consistent with G-CSF treatment. Spleen enlargement was modest. At first follow-up, all clinical and laboratory parameters had normalized. Leucocyte/lymphocyte counts and CD4/CD8 ratios were the same as during premobilization work-up and remained unchanged throughout. A single severe but likely unrelated adverse event, a case of papillary thyroid carcinoma, was reported. CONCLUSION: The studies add an observation time of almost 500 donor years to the growing body of evidence of the long-term safety of G-CSF for allogeneic donor stem cell mobilization.


Subject(s)
Blood Component Removal/methods , Blood Safety , Granulocyte Colony-Stimulating Factor/metabolism , Hematopoietic Stem Cell Mobilization/methods , Adult , Antigens, CD34/biosynthesis , CD4-Positive T-Lymphocytes/cytology , CD8-Positive T-Lymphocytes/cytology , Female , Filgrastim , Follow-Up Studies , Granulocyte Colony-Stimulating Factor/pharmacology , Humans , Longitudinal Studies , Lymphocyte Count , Male , Phenotype , Prospective Studies , Recombinant Proteins/pharmacology , Stem Cells/cytology , T-Lymphocytes/cytology , Tissue Donors , Transplantation, Homologous/methods
20.
Vox Sang ; 104(1): 19-29, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23252689

ABSTRACT

BACKGROUND: The cobas TaqScreen MPX Test, version 2.0, a multiplex, multi-dye nucleic acid amplification technology (NAT) test from Roche was evaluated by two European Blood Banks, the German Red Cross Blood Donor Service, Frankfurt, Germany and Centro de Hemoterapia y Hemodonación de Castilla y León, Valladolid, Spain. In addition, the cobas TaqScreen DPX Test was evaluated for the simultaneous detection and quantitation of parvovirus B19 and the detection of hepatitis A virus (HAV). STUDY DESIGN AND METHODS: The performances of the two tests were evaluated regarding the analytical sensitivity, the reproducibility of the tests using samples containing low concentrations of each virus and cross-contamination using samples containing high titres of virus. RESULTS: The analytical sensitivity of the MPX Test, version 2.0, obtained by the German Red Cross Blood Donor Service was 1·1, 3·9 and 43·3 IU/ml for HBV, HCV and HIV-1, respectively. The comparable analytical sensitivity at Centro de Hemoterapia y Hemodonación de Castilla y León was 3·5, 17·6 and 50·6 IU/ml for HBV, HCV and HIV-1, respectively. The analytical sensitivity of the DPX test determined by the German Red Cross Blood Donor Service was 0·6 and 3·8 IU/ml for HAV and B19. CONCLUSION: These multiplex and multi-dye blood screening assays represent a flexible NAT screening system for mini-pools between 6 and 96 samples per pool and fulfil all requirements of the European Pharmacopoeia for HCV and B19V testing of plasma for fractionation. The inclusion of a new multi-dye technology means discriminatory assays are no longer required for either test thus improving workflow, turn-around time and minimize the risk of obtaining a reactive result for which the virus cannot be identified.


Subject(s)
Blood Safety , HIV Infections/diagnosis , Hepatitis B/diagnosis , Hepatitis C/diagnosis , Nucleic Acid Amplification Techniques , Blood Banks , Blood Donors , Europe , Genotype , HIV Infections/virology , HIV-1/genetics , HIV-2/genetics , Hepacivirus/genetics , Hepatitis A/diagnosis , Hepatitis A/virology , Hepatitis A virus/genetics , Hepatitis B/virology , Hepatitis B virus/genetics , Hepatitis C/virology , Humans , Mass Screening , Parvovirus B19, Human/genetics , Reproducibility of Results
SELECTION OF CITATIONS