Artif Organs ; 36(10): 852-8, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22812488

ABSTRACT

A transcutaneous communication system (TCS) is a key technology for monitoring and controlling artificial hearts and other artificial organs in the body. In this study, we developed a new TCS that uses the human body as a conductive medium. Direct data exchange provides a higher level of communication security compared to that of wireless methods without physical constraints such as an external wire. The external and internal units of the new TCS each consist mainly of a data transmitter and a data receiver. The data transmitter has an amplitude shift keying (ASK) modulator (carrier frequencies: 4 and 10 MHz) and an electrode. The ASK-modulated data current is led into the body through the electrode, and it flows back to the energy source through the body, the data receiver, and the earth ground that includes all conductors and dielectrics in the environment that are in close proximity to the patient. Performance of the TCS was evaluated by a communication test on the surface of the human body and in an animal experiment using a goat. The TCS was able to transmit data concurrently for 4 weeks between everywhere on the surface of the body and everywhere inside the body under full-duplex communication at a transmission rate of 115 kbps. The power consumption of each TCS unit was 125 mW with an ASK-modulated current of 7 mA (root-mean-square). While further study is required to secure its safety, the newly developed TCS has promise to be a next-generation transcutaneous communication device.


Subject(s)
Heart, Artificial , Telemetry/instrumentation , Animals , Electric Conductivity , Electrodes , Equipment Design , Galvanic Skin Response , Goats , Humans , Signal Processing, Computer-Assisted/instrumentation
2.
J Artif Organs ; 15(1): 99-103, 2012 Mar.
Article in English | MEDLINE | ID: mdl-21858693

ABSTRACT

We have been developing a new transcutaneous communication system (TCS) that uses the human body as an electrical conductive medium. We studied an interface circuit of the TCS in order to optimize the leading data current into the human body effectively. Two types of LC circuits were examined for the interface circuit, one was an LC series-parallel circuit, and the other was a parallel-connected LC circuit. The LC series-parallel circuit connected to the body could be tuned to a resonant frequency, and the frequency was determined by the values of an external inductor and an external capacitor. Permittivity of the body did not influence the electrical resonance. Connection of the LC series-parallel circuit to the body degraded the quality factor Q because of the conductivity of the body. However, the LC parallel-connected circuit when connected to the body did not indicate electrical resonance. The LC series-parallel circuit restricts a direct current and a low-frequency current to flow into the body; thus, it can prevent a patient from getting a shock. According to the above results, an LC series-parallel circuit is an optimum interface circuit between the TCS and the body for leading data current into the body effectively and safely.


Subject(s)
Electric Conductivity , Equipment Design , Heart, Artificial , Monitoring, Physiologic/methods , Humans
3.
J Artif Organs ; 13(2): 117-20, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20454914

ABSTRACT

The transcutaneous communication system (TCS) is one of the key technologies for monitoring and controling artificial hearts and other artificial organs in the body. In this study, we have developed a new TCS that uses the human body as a conductive medium. Having no energy conversion from electric currents into electromagnetic waves and light provides energy-saving data transmission with a simple electrical circuit. Each unit of the TCS mainly consists of two electrodes, an amplitude shift keying (ASK) modulator and an ASK demodulator (carrier frequency: 4 and 10 MHz). A resonant frequency of an L-C tank circuit including the capacitance component of the body is tuned into each carrier frequency in order to apply the data current effectively into the body. Performance of the TCS was evaluated by a communication test on the surface of a human body. The TCS was able to transmit 3,315 bytes of data bi-directionally at a transmission rate of 115 kbps from a left wrist to a right forearm, to an abdomen and to a left calf without communication error. The power consumption of each TCS unit was 125 mW with an ASK modulated current of 7 mA (RMS). While further study is required to secure its safety, the TCS promises to be a next-generation transcutaneous communication device.


Subject(s)
Electric Conductivity , Heart, Artificial , Telemetry/instrumentation , Equipment Design , Humans , Signal Processing, Computer-Assisted