J Heart Lung Transplant ; 22(6): 674-80, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12821164

ABSTRACT

BACKGROUND: The Novacor implantable, electrically powered, wearable, left ventricular assist device (LVAD) has been used as a bridge to transplantation at our institution since 1994. Recent changes in protocol have resulted in a decreased incidence of infections, thromboembolism, and mortality. METHODS: We reviewed the medical records of all 43 patients who received implantable LVADs at the Mount Sinai Medical Center. After 1998, a number of protocol modifications were instituted. Vascular grafts were changed from a low-porosity, woven polyester (Cooley) to a gelatin-sealed, knitted polyester graft (Vascutek), the devices were implanted pre-peritoneally rather than in the posterior rectus sheath, and extensive drainage of the chest and pre-peritoneal pocket was used. The following anti-coagulation regimen was used: low-molecular-weight Dextran for 1 day, initiated after chest tube drainage <50 cc/hour; then IV heparin for 10 to 14 days, beginning at 500 U/hour, slowly increasing partial thromboplastin time to 1.5 to 2 x control; and finally Coumadin, maintaining the international normalized ratio at 2.5 to 3.5. Daily aspirin, 325 mg, was begun on post-operative Day 7. We compared 22 patients who electively underwent surgery before the changes, Group I, with 18 patients treated thereafter, Group II. RESULTS: Groups I and II were well matched with regard to age (47 vs 44 years); cause of heart failure (idiopathic, 50% vs 44%; ischemic, 50% vs 56%), and duration of support (79 vs 76 days). The incidence of thromboembolic cerebrovascular events was significantly less in Group II (6%) than in Group I (23%), p = 0.025. The incidence of bleeding increased mildly in Group I. Pocket infections occurred in 27% of Group I patients vs 11% of Group II patients, p = 0.018. Only 2 patients (11%) in Group II died while receiving device support, vs 7 (32%) in Group I, p = 0.019. CONCLUSIONS: Our results indicate that pre-peritoneal implantation, use of a new generation of vascular grafts, extensive drainage, and a more restricted anti-coagulation regimen improve outcome after Novacor LVAD implantation for advanced heart failure.


Subject(s)
Heart-Assist Devices , Adolescent , Adult , Aged , Assisted Circulation/instrumentation , Cause of Death , Equipment Design , Female , Heart Diseases/mortality , Heart Diseases/surgery , Heart Transplantation/instrumentation , Humans , Incidence , Male , Middle Aged , New York/epidemiology , Postoperative Complications/etiology , Postoperative Complications/mortality , Reoperation , Statistics as Topic , Survival Analysis , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...