Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Am J Cardiol ; 192: 221-227, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36848691

ABSTRACT

Early menopause is associated with an increased risk of cardiovascular diseases, including aortic stenosis (AS). We sought to investigate the prevalence and impact of early menopause on clinical outcomes in patients who underwent transcatheter aortic valve implantation (TAVI) for severe symptomatic AS. Women's International TAVI is a multinational, prospective, observational registry of women who underwent TAVI for severe symptomatic AS (n = 1,019). Patients were divided into 2 groups based on age of menopause: early menopause (age ≤45 years) and regular menopause (age >45 years). The primary outcome of interest was Valve Academic Research Consortium 2 efficacy end point, a composite of mortality, stroke, myocardial infarction, hospitalization for valve-related symptoms, or heart failure or valve-related dysfunction at 1-year follow-up. Of 732 patients with available data on menopause age, 173 (23.6%) were classified as having early menopause. These patients presented for TAVI at a younger age (81.6 ± 6.9 vs 82.7 ± 5.9, p = 0.05) and had a significantly lower Society of Thoracic Surgeons score (6.6 ± 4.8 vs 8.2 ± 7.1, p = 0.03) than those with regular menopause. However, the total valve calcium volume was smaller among patients with early versus regular menopause (731.8 ± 850.9 mm3 vs 807.6 ± 633.8 mm3, p = 0.002). Other co-morbidities were similar between the 2 groups. At 1-year follow-up, there were no significant differences in clinical outcomes between patients with early versus regular menopause (hazard ratio 1.00, 95% confidence interval 0.61 to 1.63, p = 1.00). In conclusion, despite presenting for TAVI at a younger age, patients with early menopause had a similar risk of adverse events as patients with regular menopause at 1 year after TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Risk Factors , Treatment Outcome , Aortic Valve Stenosis/surgery , Menopause , Aortic Valve/surgery
2.
J Am Coll Cardiol ; 81(5): 446-456, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36725173

ABSTRACT

BACKGROUND: According to current guidelines, hemodynamic status should guide the decision between immediate and delayed coronary angiography (CAG) in out-of-hospital cardiac arrest (OHCA) patients without ST-segment elevation. A delayed strategy is advised in hemodynamically stable patients, and an immediate approach is recommended in unstable patients. OBJECTIVES: This study sought to assess the frequency, predictors, and clinical impact of acute coronary occlusion in hemodynamically stable and unstable OHCA patients without ST-segment elevation. METHODS: Consecutive unconscious OHCA patients without ST-segment elevation who were undergoing CAG at Bern University Hospital (Bern, Switzerland) between 2011 and 2019 were included. Frequency and predictors of acute coronary artery occlusions and their impact on all-cause and cardiovascular mortality at 1 year were assessed. RESULTS: Among the 386 patients, 169 (43.8%) were hemodynamically stable. Acute coronary occlusions were found in 19.5% of stable and 24.0% of unstable OHCA patients (P = 0.407), and the presence of these occlusions was predicted by initial chest pain and shockable rhythm, but not by hemodynamic status. Acute coronary occlusion was associated with an increased risk of cardiovascular death (adjusted HR: 2.74; 95% CI: 1.22-6.15) but not of all-cause death (adjusted HR: 0.72; 95% CI: 0.44-1.18). Hemodynamic instability was not predictive of fatal outcomes. CONCLUSIONS: Acute coronary artery occlusions were found in 1 in 5 OHCA patients without ST-segment elevation. The frequency of these occlusions did not differ between stable and unstable patients, and the occlusions were associated with a higher risk of cardiovascular death. In OHCA patients without ST-segment elevation, chest pain or shockable rhythm rather than hemodynamic status identifies patients with acute coronary occlusion.


Subject(s)
Cardiopulmonary Resuscitation , Coronary Occlusion , Out-of-Hospital Cardiac Arrest , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/complications , Coronary Occlusion/diagnosis , Out-of-Hospital Cardiac Arrest/etiology , Out-of-Hospital Cardiac Arrest/therapy , Cardiopulmonary Resuscitation/adverse effects , Electrocardiography , Coronary Angiography/adverse effects , Chest Pain/etiology , Percutaneous Coronary Intervention/adverse effects
3.
J Am Heart Assoc ; 11(24): e025692, 2022 12 20.
Article in English | MEDLINE | ID: mdl-36533618

ABSTRACT

Background Racial and ethnic minority groups are underrepresented among patients undergoing aortic valve replacement in the United States. We evaluated the impact of race and ethnicity on the diagnosis of aortic stenosis (AS). Methods and Results In patients with transthoracic echocardiography (TTE)-confirmed AS, we assessed rates of AS diagnosis as defined by assignment of an International Classification of Diseases, Ninth Revision (ICD-9) and Tenth Revision (ICD-10) code for AS within a large multicenter electronic health record. Multivariable Cox proportional hazard and competing risk regression models were used to evaluate the 1-year rate of AS diagnosis by race and ethnicity. Among 14 800 patients with AS, the 1-year diagnosis rate for AS following TTE was 37.4%. Increasing AS severity was associated with an increased likelihood of receiving an AS diagnosis (moderate: hazard ratio [HR], 3.05 [95% CI, 2.86-3.25]; P<0.0001; severe: HR, 4.82 [95% CI, 4.41-5.28]; P<0.0001). Compared with non-Hispanic White, non-Hispanic Black (HR, 0.65 [95% CI, 0.54-0.77]; P<0.0001) and non-Hispanic Asian individuals (HR, 0.72 [95% CI, 0.57-0.90], P=0.004) were less likely to receive a diagnosis of AS. Additional factors associated with a decreased likelihood of receiving an AS diagnosis included a noncardiology TTE ordering provider (HR, 0.92 [95% CI, 0.86-0.97]; P=0.005) and TTE performed in the inpatient setting (HR, 0.72 [95% CI, 0.66-0.78]; P<0.0001). Conclusions Rates of receiving an ICD diagnostic code for AS following a diagnostic TTE are low and vary significantly by race and ethnicity and disease severity. Further studies are needed to determine if efforts to maximize the clinical recognition of TTE-confirmed AS may help to mitigate disparities in treatment.


Subject(s)
Aortic Valve Stenosis , Ethnicity , Humans , United States/epidemiology , Hispanic or Latino , Minority Groups , Asian , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery
4.
J Clin Med ; 11(15)2022 Jul 30.
Article in English | MEDLINE | ID: mdl-35956061

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of aortic stenosis, providing a viable alternative to surgical aortic valve replacement (SAVR) for patients deemed to be at prohibitive surgical risk, but also for selected patients at intermediate or low surgical risk. Nonetheless, there still exist uncertainties regarding the optimal management of patients undergoing TAVR. The selection of the optimal bioprosthetic valve for each patient represents one of the most challenging dilemmas for clinicians, given the large number of currently available devices. Limited follow-up data from landmark clinical trials comparing TAVR with SAVR, coupled with the typically elderly and frail population of patients undergoing TAVR, has led to inconclusive data on valve durability. Recommendations about the use of one device over another in given each patient's clinical and procedural characteristics are largely based on expert consensus. This review aims to evaluate the available evidence on the performance of different devices in the presence of specific clinical and anatomic features, with a focus on patient, procedural, and device features that have demonstrated a relevant impact on the risk of poor hemodynamic valve performance and adverse clinical events.

5.
J Am Coll Cardiol ; 79(9): 864-877, 2022 03 08.
Article in English | MEDLINE | ID: mdl-35241220

ABSTRACT

BACKGROUND: Despite the rapid growth of aortic valve replacement (AVR) for aortic stenosis (AS), limited data suggest symptomatic severe AS remains undertreated. OBJECTIVES: This study sought to investigate temporal trends in AVR utilization among patients with a clinical indication for AVR. METHODS: Patients with severe AS (aortic valve area <1 cm2) on transthoracic echocardiograms from 2000 to 2017 at 2 large academic medical centers were classified based on clinical guideline indications for AVR and divided into 4 AS subgroups: high gradient with normal left ventricular ejection fraction (LVEF) (HG-NEF), high gradient with low LVEF (HG-LEF), low gradient with normal LVEF (LG-NEF), and low gradient with low LVEF (LG-LEF). Utilization of AVR was examined and predictors identified. RESULTS: Of 10,795 patients, 6,150 (57%) had an indication or potential indication for AVR, of whom 2,977 (48%) received AVR. The frequency of AVR varied by AS subtype with LG groups less likely to receive an AVR (HG-NEF: 70%, HG-LEF: 53%, LG-NEF: 32%, LG-LEF: 38%, P < 0.001). AVR volumes grew over the 18-year study period but were paralleled by comparable growth in the number of patients with an indication for AVR. In patients with a Class I indication, younger age, coronary artery disease, smoking history, higher hematocrit, outpatient index transthoracic echocardiogram, and LVEF ≥0.5 were independently associated with an increased likelihood of receiving an AVR. AVR was associated with improved survival in each AS-subgroup. CONCLUSIONS: Over an 18-year period, the proportion of patients with an indication for AVR who did not receive AVR has remained substantial despite the rapid growth of AVR volumes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Humans , Severity of Illness Index , Stroke Volume , Treatment Outcome , Ventricular Function, Left
6.
Am J Cardiol ; 165: 81-87, 2022 02 15.
Article in English | MEDLINE | ID: mdl-34920860

ABSTRACT

Acute kidney injury after transcatheter aortic valve implantation (TAVI) has been associated with adverse outcomes; however, data are limited on the subacute changes in renal function that occur after discharge and their impact on clinical outcomes. This study investigates the relation between subacute changes in kidney function at 30 days after TAVI and survival. Patients from 2 centers who underwent TAVI and survived beyond 30 days with baseline, in-hospital, and 30-day measures of renal function were retrospectively analyzed. Patients were stratified based on change in estimated glomerular filtration rate (eGFR) from baseline to 30 days as follows: improved (≥15% higher than baseline), worsened (≤15% lower), or unchanged (values in between). Univariable and multivariable models were constructed to identify predictors of subacute changes in renal function and of 2-year mortality. Of the 492 patients who met inclusion criteria, eGFR worsened in 102 (22%), improved in 110 (22%), and was unchanged in 280 (56%). AKI occurred in 90 patients (18%) and in only 27% of patients with worsened eGFR at 30 days. After statistical adjustment, worsened eGFR at 30 days (hazard ratio vs unchanged eGFR 2.09, 95% CI 1.37 to 3.19, p <0.001) was associated with worse survival, whereas improvement in renal function was not associated with survival (hazard ratio vs unchanged eGFR 1.30, 95% CI 0.79 to 2.11, p = 0.30). Worsened renal function at 30 days after TAVI is associated with increased mortality after TAVI. In conclusion, monitoring renal function after discharge may identify patients at high risk of adverse outcomes.


Subject(s)
Acute Kidney Injury/epidemiology , Aortic Valve Stenosis/surgery , Mortality , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Cohort Studies , Female , Glomerular Filtration Rate , Humans , Male , Multivariate Analysis , Retrospective Studies , Time Factors
7.
J Am Heart Assoc ; 10(19): e021014, 2021 10 05.
Article in English | MEDLINE | ID: mdl-34585593

ABSTRACT

Background Concerns about discordance between echocardiographic and invasive mean gradients after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEVs) versus self-expanding valves (SEVs) exist. Methods and Results In a multicenter study, direct-invasive and echocardiography-derived transvalvular mean gradients obtained before and after TAVR were compared as well as post-TAVR and discharge echocardiographic mean gradients in BEVs versus SEVs in 808 patients. Pre-TAVR, there was good correlation (R=0.614; P<0.0001) between direct-invasive and echocardiography-derived mean gradients and weak correlation (R=0.138; P<0.0001) post-TAVR. Compared with post-TAVR echocardiographic mean gradients, both valves exhibit lower invasive and higher discharge echocardiographic mean gradients. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. An ejection fraction <50% (P=0.028) and higher Society of Thoracic Surgeons predicted risk of mortality score (P=0.007), but not invasive or echocardiographic mean gradient ≥10 mm Hg (P=0.378 and P=0.341, respectively), nor discharge echocardiographic mean gradient ≥20 mm Hg (P=0.393), were associated with increased 2-year mortality. Conclusions Invasively measured and echocardiography-derived transvalvular mean gradients correlate well in aortic stenosis but weakly post-TAVR. Post-TAVR, echocardiography overestimates transvalvular mean gradients compared with invasive measurements, and poor correlation suggests these modalities cannot be used interchangeably. Moreover, echocardiographic mean gradients are higher on discharge than post-TAVR in all valves. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. Immediately post-TAVR, elevated echocardiographic-derived mean gradients should be assessed with caution and compared with direct-invasive mean gradients. A low ejection fraction and higher Society of Thoracic Surgeons score, but not elevated mean gradients, are associated with increased 2-year mortality.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography , Hemodynamics , Humans , Prosthesis Design , Treatment Outcome
8.
Eur Heart J Digit Health ; 2(1): 90-103, 2021 Mar.
Article in English | MEDLINE | ID: mdl-34048509

ABSTRACT

AIMS: Impaired physical function is common in patients undergoing transcatheter aortic valve replacement (TAVR) and associated with worse outcomes. Participation in centre-based cardiac rehabilitation (CR) after cardiovascular procedures is sub-optimal. We aimed to test a home-based mobile health exercise intervention as an alternative or complementary approach. METHODS AND RESULTS: At five centres, after a run-in period, eligible individuals treated with TAVR were randomized 1:1 at their 1-month post-TAVR visit to an intervention group [activity monitor (AM) with personalized daily step goal and resistance exercises] or a control group for 6 weeks. Among 50 participants, average age was 76 years, 34% were female, average STS score was 2.91.8, and 40% had Short Physical Performance Battery (SPPB) 9. Daily compliance with wearing the AM and performing exercises averaged 8590%. In the intention to treat population, there was no evidence that the intervention improved the co-primary endpoints: daily steps +769 (95% CI 244 to +1783); SPPB +0.68 (0.27 to 1.53); and Kansas City Cardiomyopathy Questionnaire 1.7 (9.1 to 7.1). The intervention did improve secondary physical activity parameters, including moderate-to-intense daily active minutes (P<0.05). In a pre-specified analysis including participants who did not participate in CR (n=30), the intervention improved several measures of physical activity: +1730 (1003360) daily steps; +66 (28105) daily active minutes; +53 (2780) moderate-to-intense active minutes; and 157 (265 to 50) sedentary minutes. CONCLUSION: Among selected participants treated with TAVR, this study did not provide evidence that a pragmatic home-based mobile health exercise intervention improved daily steps, physical performance or QoL for the overall cohort. However, the intervention did improve several measures of daily activity, particularly among individuals not participating in CR. TRIAL REGISTRY: Clinicaltrials.gov NCT03270124.

SELECTION OF CITATIONS
SEARCH DETAIL
...