Zh Mikrobiol Epidemiol Immunobiol ; (6): 23-30, 1990 Jun.
Article in Russian | MEDLINE | ID: mdl-2220217

ABSTRACT

The optimum conditions for using the method of radioimmunoprecipitation (RIP) for the detection of human immunodeficiency virus (HIV) in serum samples have been established. Out of several available cell lines persistently infected with HIV, specially selected line 17 has been chosen. The characteristic feature of this is the high and stable (under the conditions of prolonged cultivation) accumulation of virus-specific proteins in infected cells. The optimum conditions for making the test and its evaluation have also been established. The data of literature on the advantages of the method of RIP over such traditional methods as the enzyme immunoassay and immunoblotting have been confirmed. Thus, the presence of specific antibodies in several serum samples registered as false negative has been established. The intertypical reactivity of two serotypes of the virus, HIV-1 and HIV-2, has been studied. Cross reactivity of antibodies with respect to the HIV gene gag, but not with respect to viral glycoproteids, has been established. Ideas on the expediency and prospects of using RIP for the serological control of HIV infection are presented.


Subject(s)
AIDS Serodiagnosis/methods , Radioimmunoprecipitation Assay/methods , Antibody Specificity , Cell Line , Cells, Cultured , Evaluation Studies as Topic , False Negative Reactions , HIV Antibodies/blood , HIV Infections/diagnosis , HIV-1 , HIV-2 , Humans