Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Nanotechnology ; 33(31)2022 May 13.
Article in English | MEDLINE | ID: mdl-35443239

ABSTRACT

Over the last decade, lead halide perovskites have attracted significant research attention in the field of photovoltaics, light-emitting devices, photodetection, ionizing radiation detection, etc, owing to their outstanding optoelectrical properties. However, the commercial applications of lead-based perovskite devices are restricted due to the poor ambient stability and toxicity of lead. The encapsulation of lead-based devices can reduce the possible leakage of lead. However, it is hard to ensure safety during large-scale production and long-term storage. Recently, considerable efforts have been made to design lead-free perovskites for different optoelectronic applications. Metal halide double perovskites with the general formula of A2MIMIIIX6or A2MIVX6could be potentially considered as green and stable alternatives for different optoelectronic applications. In this review article, we focus on the recent progress and findings on lead-free halide double perovskites for x-ray and UV-vis photodetection applications. Lead-free halide double perovskite has recently drawn a great deal of attention for superior x-ray detection due to its high absorption coefficient, large carrier mobility-lifetime product, and large bulk resistance. In addition, these materials exhibit good performance in photodetection in the UV-vis region due to high photocarrier generation and efficient carrier separation. In this review, first, we define the characteristics of lead-free double perovskite materials. The fundamental characteristics and beneficial properties of halide perovskites for direct and indirect x-ray detection are then discussed. We comprehensively review recent developments and efforts on lead-free double perovskite for x-ray detection and UV-vis photodetection. We bring out the current challenges and opportunities in the field and finally present the future outlook for developing lead-free double perovskite-based x-ray and UV-vis photodetectors for practical applications.

2.
J Radiol Prot ; 40(3): N31-N38, 2020 09.
Article in English | MEDLINE | ID: mdl-32408280

ABSTRACT

We report on the retrofitting of a standard DP2 environmental radiation monitor replacing the photomultiplier tube with a silicon photomultiplier (SiPM). The use of a SiPM has several advantages for a hand-held radiation monitor, including convenient low-voltage operation and physical robustness. We report the detection efficiency and alpha/beta discrimination performance of the modified probe compared with an unmodified version.


Subject(s)
Radiation Monitoring/instrumentation , Silicon/chemistry , Equipment Design
3.
Sensors (Basel) ; 19(18)2019 Sep 04.
Article in English | MEDLINE | ID: mdl-31487922

ABSTRACT

In response to the Fukushima Daiichi Nuclear Power Plant accident, there has occurred the unabated growth in the number of airborne platforms developed to perform radiation mapping-each utilising various designs of a low-altitude uncrewed aerial vehicle. Alongside the associated advancements in the airborne system transporting the radiation detection payload, from the earliest radiological analyses performed using gas-filled Geiger-Muller tube detectors, modern radiation detection and mapping platforms are now based near-exclusively on solid-state scintillator detectors. With numerous varieties of such light-emitting crystalline materials now in existence, this combined desk and computational modelling study sought to evaluate the best-available detector material compatible with the requirements for low-altitude autonomous radiation detection, localisation and subsequent high spatial-resolution mapping of both naturally occurring and anthropogenically-derived radionuclides. The ideal geometry of such detector materials is also evaluated. While NaI and CsI (both elementally doped) are (and will likely remain) the mainstays of radiation detection, LaBr3 scintillation detectors were determined to possess not only a greater sensitivity to incident gamma-ray radiation, but also a far superior spectral (energy) resolution over existing and other potentially deployable detector materials. Combined with their current competitive cost, an array of three such composition cylindrical detectors were determined to provide the best means of detecting and discriminating the various incident gamma-rays.

4.
Nanotechnology ; 23(23): 235502, 2012 Jun 15.
Article in English | MEDLINE | ID: mdl-22595835

ABSTRACT

Semiconducting polymers have previously been used as the transduction material in x-ray dosimeters, but these devices have a rather low detection sensitivity because of the low x-ray attenuation efficiency of the organic active layer. Here, we demonstrate a way to overcome this limitation through the introduction of high density nanoparticles having a high atomic number (Z) to increase the x-ray attenuation. Specifically, bismuth oxide (Bi(2)O(3)) nanoparticles (Z = 83 for Bi) are added to a poly(triarylamine) (PTAA) semiconducting polymer in the active layer of an x-ray detector. Scanning electron microscopy (SEM) reveals that the Bi(2)O(3) nanoparticles are reasonably distributed in the PTAA active layer. The reverse bias dc current-voltage characteristics for PTAA-Bi(2)O(3) diodes (with indium tin oxide (ITO) and Al contacts) have similar leakage currents to ITO/PTAA/Al diodes. Upon irradiation with 17.5 keV x-ray beams, a PTAA device containing 60 wt% Bi(2)O(3) nanoparticles demonstrates a sensitivity increase of approximately 2.5 times compared to the plain PTAA sensor. These results indicate that the addition of high-Z nanoparticles improves the performance of the dosimeters by increasing the x-ray stopping power of the active volume of the diode. Because the Bi(2)O(3) has a high density, it can be used very efficiently, achieving a high weight fraction with a low volume fraction of nanoparticles. The mechanical flexibility of the polymer is not sacrificed when the inorganic nanoparticles are incorporated.


Subject(s)
Metal Nanoparticles/radiation effects , Metals, Heavy/radiation effects , Radiometry/instrumentation , Semiconductors , Equipment Design , Equipment Failure Analysis , Oxides/radiation effects , Radiation Dosage , Sensitivity and Specificity , X-Rays
5.
J Instrum ; 6(12)2011 Dec.
Article in English | MEDLINE | ID: mdl-22737179

ABSTRACT

We have developed a pixellated high energy X-ray detector instrument to be used in a variety of imaging applications. The instrument consists of either a Cadmium Zinc Telluride or Cadmium Telluride (Cd(Zn)Te) detector bump-bonded to a large area ASIC and packaged with a high performance data acquisition system. The 80 by 80 pixels each of 250 µm by 250 µm give better than 1 keV FWHM energy resolution at 59.5 keV and 1.5 keV FWHM at 141 keV, at the same time providing a high speed imaging performance. This system uses a relatively simple wire-bonded interconnection scheme but this is being upgraded to allow multiple modules to be used with very small dead space. The readout system and the novel interconnect technology is described and how the system is performing in several target applications.

6.
Biochem Biophys Res Commun ; 325(4): 1433-7, 2004 Dec 24.
Article in English | MEDLINE | ID: mdl-15555587

ABSTRACT

DNA biosensors based on self-assembled multi-walled carbon nanotubes (MWNTs) were described in this paper, in which the probe DNA oligonucleotides were immobilized by forming covalent amide bonds between carboxyl groups at the nanotubes and amino groups at the ends of the DNA oligonucleotides. Hybridization between the probe and target DNA oligonucleotides was confirmed by the changes in the voltammetric peak of the indicator of methylene blue. Our results demonstrate that the DNA biosensors based on self-assembled MWNTs had a higher hybridization efficiency compared to those based on random MWNTs. In addition, the developed DNA biosensors also had a high selectivity of hybridization detection.


Subject(s)
Biosensing Techniques/instrumentation , DNA/analysis , DNA/chemistry , Electrochemistry/instrumentation , In Situ Hybridization/instrumentation , Nanotubes, Carbon/chemistry , Nanotubes, Carbon/ultrastructure , Adsorption , Biosensing Techniques/methods , Coated Materials, Biocompatible/chemistry , Crystallization/methods , Electrochemistry/methods , Equipment Design , Equipment Failure Analysis , In Situ Hybridization/methods , Oligonucleotide Probes/chemistry
7.
J Synchrotron Radiat ; 5(Pt 3): 252-5, 1998 May 01.
Article in English | MEDLINE | ID: mdl-15263487

ABSTRACT

An integrating pixel-array detector for recording time-resolved X-ray diffraction measurements on microsecond timescales has been designed and tested as a 4 x 4 pixel prototype. Operational characteristics and radiation tolerance are discussed. A 100 x 92 array with 151.2 micro m square pixels is currently under construction.

SELECTION OF CITATIONS
SEARCH DETAIL
...