J Clin Med ; 12(4)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36835805

ABSTRACT

BACKGROUND AND PURPOSE: Provisional prostheses in restorations over several implants with immediate loading in completely edentulous patients increase the risk of frequent structural fractures. An analysis was performed of the resistance to fracture of prosthetic structures with cantilevers using graphene-doped polymethyl methacrylate (PMMA) resins and CAD-CAM technology. METHODS: A master model was produced with four implants measuring 4 mm in diameter and spaced 3 mm apart, over which 44 specimens representing three-unit fixed partial prostheses with a cantilever measuring 11 mm were placed. These structures were cemented over titanium abutments using dual cure resin cement. Twenty-two of the 44 units were manufactured from machined PMMA discs, and 22 were manufactured from PMMA doped with graphene oxide nanoparticles (PMMA-G). All of the samples were tested in a chewing simulator with a load of 80 N until fracture or 240,000 load applications. RESULTS: The mean number of load applications required for temporary restoration until the fracture was 155,455 in the PMMA-G group versus 51,136 in the PMMA group. CONCLUSIONS: Resistance to fracture under cyclic loading was three times greater in the PMMA-G group than in the PMMA group.