Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
J Curr Ophthalmol ; 34(1): 56-59, 2022.
Article in English | MEDLINE | ID: mdl-35620375

ABSTRACT

Purpose: To analyze the biometric values and the prevalence of corneal astigmatism in cataract surgery candidates. Methods: This is a prospective study. Ocular biometric values and corneal keratometric astigmatism were measured by optical low-coherence reflectometry (Lenstar LS 900) before surgery in patients who were candidates for cataract extraction surgery. Descriptive measurements of biometric dimensions and keratometric cylinder data and their correlations with sex and age were evaluated. Results: Ocular biometric and keratometric values from 2084 eyes of 2084 patients (mean age 66.43, range 19-95 years) were analyzed. The mean values were as follows: corneal astigmatism 0.89 diopter (D), mean corneal keratometry 44.29 D, central corneal thickness 534 µ, internal anterior chamber depth (ACD) 3.11 mm, lens thickness 4.50 mm, and axial length 23.35 mm. Corneal astigmatism was <1.25 D in 1660 (79.5%) of eyes. Astigmatism was with-the-rule in 976 (46.8%) of eyes, against-the-rule (ATR) in 702 (33.7%), and oblique in 406 (19.5%). Analysis of corneal astigmatism revealed a change toward "ATR" with age which was not statistically significant. The ACD was correlated with age. The amount of corneal astigmatism had no correlation with age and sex. Conclusion: Corneal astigmatism was higher than 1.25 D in about 21% of cataract surgery candidates with slight differences between the various age ranges and had no correlation with age and sex.

2.
Int Ophthalmol ; 42(10): 2987-2996, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35389172

ABSTRACT

PURPOSE: To determine the effect of a single-segment intrastromal corneal ring segment (ICRS; Intacs SK) on early keratoconus (KCN) and pellucid marginal degeneration (PMD). METHODS: It is a prospective interventional study. One hundred twenty-four eyes (99 patients) with KCN and 36 eyes (26 patients) with PMD at early stage (the maximum keratometric reading less than 55 diopters) were included to ICRS implantation using femtosecond laser at a tertiary university-based hospital and a private outpatient center. The uncorrected distance and spectacle-corrected visual acuity (UDVA and SCDVA), manifest spherical and cylindrical refractions, and keratometry indices were measured preoperatively and postoperatively, 1 week, 2 and 6 months. RESULTS: One week after surgery, significant improvements were observed in UDVA, SCDVA, cylinder and keratometry readings of both KCN and PMD groups (all P < 0.05) with no significant changes afterward. No significant change occurred in the sphere refraction of PMD group (P = 0.10) in contrast to KCN group (P < 0.001). Corneal irregularity of KCN group in central 3 and 5 mm zones increased at 1 week (both P < 0.001) and then started to decrease up to 6 months. However, the corneal irregularity of PMD group had significant reduction only at 1 week in 5-mm zone (P = 0.02) and 2 months in 3-mm zone (P = 0.01) postoperatively. The final efficacy indexes were 1.44 ± 0.71 and 0.87 ± 0.40 in KCN and PMD groups, respectively. CONCLUSION: Visual acuity, refractive errors and keratometry values have been improved after one-segment Intacs SK implantation in early KCN and PMD patients.


Subject(s)
Keratoconus , Corneal Stroma/surgery , Corneal Topography , Humans , Keratoconus/diagnosis , Keratoconus/surgery , Prospective Studies , Prostheses and Implants , Prosthesis Implantation , Refraction, Ocular , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...