Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Minim Invasive Ther Allied Technol ; 26(4): 232-239, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28635406

ABSTRACT

BACKGROUND: Many minimally invasive surgical procedures and assisting robotic systems have been developed to further minimize the number and size of incisions in the body surface. This paper presents a new idea combining the advantages of modular robotic surgery, single incision laparoscopic surgery and needlescopic surgery. MATERIAL AND METHODS: In the proposed concept, modules carrying therapeutic or diagnostic tools are inserted in the abdominal cavity from the navel as in single incision laparoscopic surgery and assembled to 3-mm needle shafts penetrating the abdominal wall. RESULTS: A three degree-of-freedom robotic module measuring 16 mm in diameter and 51 mm in length was designed and prototyped. The performance of the three connected robotic modules was evaluated. CONCLUSION: A new idea of modular robotic surgery was proposed, and demonstrated by prototyping a 3-DOF robotic module. The performance of the connected robotic modules was evaluated, and the challenges and future work were summarized.


Subject(s)
Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Equipment Design , Humans , Laparoscopy/methods
2.
Article in English | MEDLINE | ID: mdl-25571575

ABSTRACT

In femoral fracture reduction, orthopedic surgeons must pull distal bone fragments with great traction force and return them to their correct positions, by referring to 2D-fluoroscopic images. Since this method is physically burdensome, the introduction of robotic assistance is desirable. While such robots have been developed, adequate control methods have not yet been established because of the lack of experimental data. It is difficult to obtain accurate data using cadavers or animals because they are different from the living human body's muscle characteristics and anatomy. Therefore, an experimental model for simulating human femoral characteristics is required. In this research, human muscles are reproduced using a McKibben-type pneumatic rubber actuator (artificial muscle) to develop a model that simulates typical femur muscles using artificial muscles.


Subject(s)
Artificial Organs , Femoral Fractures/pathology , Models, Biological , Animals , Femoral Fractures/therapy , Femur/anatomy & histology , Fluoroscopy , Humans , Muscle Contraction , Robotics
SELECTION OF CITATIONS
SEARCH DETAIL
...