1.
J Hosp Infect ; 106(2): 254-257, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32795568

ABSTRACT

Markers for preoperative skin marking are used several times and bear a risk of transmitting bacteria. Bacterial contamination was assessed by sonication and culture. Antimicrobial susceptibility testing (AST) was performed for facultative pathogens to assess multi-drug resistance (MDR). An accelerated failure time model was applied to assess the statistical relationship between the bacterial contamination and the filling status of markers. Of 45 markers, 13 had a colony count <10 cfu/mL and 32 had counts from 10 to 12,500 cfu/mL. Three markers were colonized by Staphylococcus aureus. No MDR bacteria were found. We recommend single use of markers to reduce transmission risk.


Subject(s)
Bacteria/isolation & purification , Bacterial Infections/transmission , Equipment Contamination , Preoperative Care/instrumentation , Surgical Equipment/microbiology , Anti-Bacterial Agents/pharmacology , Bacteria/classification , Colony Count, Microbial , Drug Resistance, Multiple, Bacterial , Humans , Microbial Sensitivity Tests , Staphylococcal Infections/microbiology , Staphylococcal Infections/transmission
2.
Med Klin Intensivmed Notfmed ; 114(2): 166-172, 2019 Mar.
Article in German | MEDLINE | ID: mdl-30083872

ABSTRACT

BACKGROUND: Relatives of intensive care patients have a very high need for information. This is due to the acute and serious, often life-threatening illness of the patients and the very complex and technical environment of an intensive care unit (ICU). Unmet needs for information can increase anxiety, sleep disorders, stress, and depressive symptoms in the relatives. OBJECTIVES: The potential of the ICU families website in terms of usability and functionality during real-time testing were evaluated. METHODS: The ICU families project created a dynamic online information platform in the form of a password-protected website. It contains pictures, written explanations, 5 movies, a forum and a diary function. The usability of the website was tested among 10 lay people and 10 experts (7 nurses and 3 physicians) according to the Think Aloud Method. RESULTS: The outcome is qualitative feedback based on video documentation by laypeople and suggestions by experts. Criticisms mentioned by the test subjects were insufficient image material, small size of the operator contact link and lack of a home button. With a mean of 9.1 (rating scale, 0 = very poor, 10 = very good), the website was almost universally recommended by the experts. CONCLUSIONS: This usability test of a website for relatives of ICU patients conducted among 20 test subjects showed the biggest challenges related to solving individual test scenarios and provided valuable hints for improving website usability. Features of the website highlighted as positive were the clear layout, the symbols, the diary and the consideration of children. This information was used to improve the site for subsequent roll-out in a randomized, controlled and multicentre study.


Subject(s)
Critical Illness , Family/psychology , Intensive Care Units , Internet , Anxiety , Child , Critical Care , Depression , Humans
3.
Int J Obes Relat Metab Disord ; 25(1): 115-20, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11244466

ABSTRACT

OBJECTIVE: Leptin regulates energy production rates and body weight, which are frequently altered in hyperthyroidism. Data on a possible interaction between leptin and thyroid hormones are controversial. We assessed leptin serum concentrations, BMI, proportional fat tissue mass and thyroid hormones in hyperthyroid patients in a long-term follow-up after radioiodine therapy. DESIGN: The study included 28 hyperthyroid patients (mean age 66 y) before and up to one y after radioiodine therapy. Leptin and thyroid hormones, general parameters, BMI, proportional fat tissue (PFT) measurements by DEXA and thyroid morphology were recorded. Twenty-four age-matched euthyroid individuals (mean age 63 y) served as controls. RESULTS: At baseline, leptin concentrations were significantly decreased in all hyperthyroid patients as compared to controls. One year after radioiodine therapy, 71% of the patients were euthyroid (group A) and 29% remained hyperthyroid (group B). BMI and PFT increased in both groups. While leptin concentrations remained low in group B, they normalised in group A after 6 to 12 months. Changes in leptin and thyroid hormone concentrations were positively correlated in group A patients (r=0.49, P=0.03) but not in patients remaining hyperthyroid. CONCLUSION: Our data indicate a dissociation in the regulation of plasma leptin and BMI as well as proportional fat tissue in hyperthyroid patients which may be attributable to differences in lean and adipose mass weight gain after radioiodine therapy or direct influences of thyroid hormones on leptin regulation. International Journal of Obesity (2001) 25, 115-120


Subject(s)
Body Weight/physiology , Hyperthyroidism/radiotherapy , Iodine Radioisotopes/therapeutic use , Leptin/blood , Absorptiometry, Photon , Adipose Tissue , Aged , Aged, 80 and over , Body Mass Index , Bone Density , Female , Humans , Hyperthyroidism/blood , Hyperthyroidism/physiopathology , Male , Middle Aged , Thyroid Hormones/blood , Thyrotropin/blood
4.
Diabet Med ; 17(5): 371-5, 2000 May.
Article in English | MEDLINE | ID: mdl-10872536

ABSTRACT

AIMS: In intensified insulin therapy, the recent development of short-acting insulin analogues with a very rapid onset of action forces a new discussion in terms of the optimal injection-meal interval. This study evaluated prandial glycaemia in patients with Type 1 diabetes following the subcutaneous injection of soluble human insulin (HI) and the insulin analogue insulin aspart (IAsp) at different injection-meal intervals and investigated whether administration of IAsp after the meal might provide satisfactory metabolic control. METHODS: In a randomized, double-blind, double-dummy, four-period crossover study, 20 Type 1 diabetic patients were investigated. Prandial insulin was administered 15 min before the start of the meal (HI(-15min)), immediately before the meal (HI(0min); IAsp(0min)) and 15 min after the start of the meal (IAsp(+15min)). RESULTS: Plasma glucose excursions from baseline levels during the 4 h (PGexc) were highest with HI(0min) (17.9 mmol.l(-1).h; P < 0.05 vs. other treatments) and were not statistically different for HI(-15min), IAsp(0min) and IAsp(15min) (13.6, 11.9 and 14.2 mmol.l(-1).h, respectively). Maximum concentration of plasma glucose (PGmax) was lowest with IAsp(0min) (11.2 mmol/l; P < 0.05 vs. other treatments). PGmax was comparable with HI(-15min), HI(0min) and IAsp(+15min) (13.3, 14.1 and 13.2 mmol/l, respectively). CONCLUSIONS: With regard to prandial glycaemia IAsp(+15min) is as effective as HI(-5min) and superior to HI(0min). Thus, post-prandial dosing of the insulin analogue IAsp offers an attractive and feasible therapeutic option for well-controlled patients with Type 1 diabetes mellitus.


Subject(s)
Diabetes Mellitus, Type 1/drug therapy , Food , Hypoglycemic Agents/administration & dosage , Insulin/analogs & derivatives , Insulin/administration & dosage , Adult , Blood Glucose/metabolism , Cross-Over Studies , Diabetes Mellitus, Type 1/blood , Double-Blind Method , Female , Humans , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Aspart , Male , Middle Aged
5.
Am J Physiol Endocrinol Metab ; 278(2): E352-6, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10662720

ABSTRACT

The absolute concentration of albumin was measured in the interstitial fluid of subcutaneous adipose tissue and skeletal muscle in six healthy volunteers by combining the method of open-flow microperfusion and the no-net-flux calibration technique. By use of open-flow microperfusion, four macroscopically perforated double lumen catheters were inserted into the tissue regions of interest and constantly perfused. Across the macroscopic perforations of the catheters interstitial fluid was partially recovered in the perfusion fluid. Catheters were perfused with five solutions, each containing different concentrations of albumin. Absolute interstitial albumin concentrations were calculated by applying linear regression analysis to perfusate vs. sampled albumin concentration (no-net-flux calibration technique). Interstitial albumin concentrations were significantly lower (P < 0.0001) in adipose tissue (7.36 g/l; r = 0.99, P < 0.0003; range: 4.3-10.7 g/l) and in skeletal muscle (13.25 g/l; r = 0.99, P < 0.0012; range: 9.7 to 15.7 g/l) compared with the serum concentration (48.9 +/- 0.7 g/l, mean +/- SE, n = 6; range: 46.4-50.4 g/l). Furthermore, interstitial albumin concentrations were significantly higher in skeletal muscle compared with adipose tissue (P < 0.01). The study indicates that open-flow microperfusion allows stable sampling of macromolecules from the interstitial space of peripheral tissue compartments. Moreover, the present data report for the first time in healthy humans in vivo the true albumin concentrations of interstitial fluid of adipose tissue and skeletal muscle.


Subject(s)
Adipose Tissue/chemistry , Albumins/analysis , Extracellular Space/chemistry , Muscle, Skeletal/chemistry , Adult , Humans , Male , Perfusion , Serum Albumin/analysis
6.
Diabetes ; 48(5): 1070-81, 1999 May.
Article in English | MEDLINE | ID: mdl-10331412

ABSTRACT

Recent experimental evidence suggests that estimates of glucose effectiveness (S(G)) from the minimal model of unlabeled glucose disappearance (Cold-MM) are in error. The single-compartment glucose distribution assumption embedded in the model has been indicated as a possible source of error. In this study, to directly examine the single-compartment assumption, we measured plasma and interstitial glucose concentrations after intravenous glucose injection. Additionally, we compared the accuracy of the estimates of glucose effectiveness from the Cold-MM and the single-compartment tracer minimal model (Hot-MM). Paired labeled intravenous glucose tolerance tests (IVGTTs) were performed in each of six C-peptide-negative type 1 diabetic subjects. Two different insulin infusion protocols were used: an infusion at constant basal rates and an infusion at variable rates to mimic a normal insulin response. During the labeled IVGTT with basal insulin infusion, the microperfusion technique was employed to sample adipose tissue interstitial fluid. Marked differences between the plasma and interstitial dynamics of (cold) glucose were observed during the first 22 min after glucose injection. These results suggest that the requirements for a single-compartment representation of glucose kinetics are not satisfied during at least the first 22 min of an IVGTT. Data from the labeled IVGTT with normal insulin response were used to identify the minimal-model parameters. The measure of S(G) derived using the Cold-MM was 3.44-fold higher than the direct measure obtained from the labeled IVGTT with basal insulin infusion (0.0179+/-0.0027 vs. 0.0052+/-0.0010 min(-1), P<0.01). The measure of glucose effectiveness (S(G)*) derived by the Hot-MM was 1.36-fold higher than the direct measure available from the labeled IVGTT with basal insulin infusion (0.0079+/-0.0013 vs. 0.0058+/-0.0004 min(-1), P>0.26). These results suggest that the Hot-MM is more appropriate for the evaluation of glucose effectiveness than the Cold-MM.


Subject(s)
Blood Glucose/metabolism , Diabetes Mellitus, Type 1/metabolism , Glucose/administration & dosage , Adult , C-Peptide/blood , Deuterium , Extracellular Space/chemistry , Female , Glucose/analysis , Glucose Tolerance Test , Humans , Injections, Intravenous , Insulin/blood , Kinetics , Male , Mathematics , Middle Aged , Models, Biological , Sodium/blood
7.
Am J Physiol ; 276(2): E401-8, 1999 02.
Article in English | MEDLINE | ID: mdl-9950802

ABSTRACT

To gain direct access to the interstitial fluid (ISF), a new technique called open-flow microperfusion has been evaluated. This method is based on a double-lumen catheter with macroscopic (0.3-0.5 mm diameter) perforations that is inserted into the subcutaneous adipose tissue and constantly perfused. Thus partial equilibration between the ISF and the perfusion fluid occurs. The glucose concentration of the ISF was determined by established (zero flow rate, no net flux, and recirculation procedures) and new (ionic reference and suction technique) calibration methods by use of open-flow microperfusion. The data show that 1) the glucose concentration in the ISF is significantly lower than the corresponding arterialized venous plasma values during basal steady-state conditions (adipose tissue 3.2 +/- 0.10 mM, plasma 5.27 +/- 0.12 mM) as well as during hyperglycemic clamp experiments (adipose tissue 7.3 +/- 0.13 mM, plasma 9.91 +/- 0.16 mM), and 2) it is possible to determine the recovery continuously by using the ion concentration of the ISF as an internal standard (ionic reference).


Subject(s)
Adipose Tissue/metabolism , Extracellular Space/metabolism , Perfusion/methods , Adult , Calibration , Glucose/metabolism , Homeostasis/physiology , Humans , Hyperglycemia/metabolism , Microdialysis/methods , Osmolar Concentration , Reference Values , Suction/methods
8.
J Clin Endocrinol Metab ; 83(12): 4394-401, 1998 Dec.
Article in English | MEDLINE | ID: mdl-9851784

ABSTRACT

Open flow microperfusion and a novel calibration technique (ionic reference technique) were evaluated for the frequent measurement of the absolute lactate concentration in sc adipose tissue. Furthermore, the influence of the plasma insulin concentration on the lactate concentration of sc adipose tissue was investigated during hyperglycemia. Sixteen lean healthy young men participated in the studies. In the postabsorbtive state the mean sc lactate concentrations were 1.29 and 1.36 mmol/L for the ionic reference technique and the no net flux protocol, respectively (not significant, P > 0.05). The simultaneously measured arterialized plasma lactate concentration was significantly lower at 0.77 mmol/L (P < 0.05). Both the sc lactate concentration (1.8+/-0.33 mmol/L) and the plasma lactate concentration (0.96+/-0.03 mmol/L) were significantly elevated during a hyperinsulinemic euglycemic clamp experiment. During a hyperglycemic clamp experiment the sc lactate concentration reached a significantly elevated plateau (2.15+/-0.27 mmol/L) that was not influenced by the increasing plasma insulin concentration. It is concluded that 1) open flow microperfusion combined with the ionic reference technique enables frequent measurement of the sc lactate concentration; 2) sc adipose tissue is a significant source of lactate release in the postabsorbtive state as well as during hyperinsulinemic clamp conditions; and 3) insulin concentrations greater than 180 pmol/L have no further influence on adipocyte stimulation of sc adipose tissue with respect to lactate release.


Subject(s)
Adipose Tissue/metabolism , Lactic Acid/metabolism , Adult , Glucose Clamp Technique , Humans , Hyperglycemia/blood , Hyperglycemia/metabolism , Hyperinsulinism/metabolism , Male , Osmolar Concentration , Perfusion/methods , Skin
9.
Diabetes Care ; 21(4): 585-90, 1998 Apr.
Article in English | MEDLINE | ID: mdl-9571347

ABSTRACT

OBJECTIVE: To evaluate the clinical and analytical accuracy of home blood glucose meters. RESEARCH DESIGN AND METHODS: Six blood glucose meters--Reflolux S (Boehringer Mannheim, Mannheim, Germany), One Touch II (LifeScan, Milpitas, CA), Glucocard Memory (Menarini, Florence, Italy), Precision QID (Medisense, Cambridge, U.K.), HaemoCue (HaemoCue, Angelholm, Sweden), and Accutrend alpha (Boehringer Mannheim, Mannheim, Germany)--were compared with a reference method (Beckman Glucose Analyzer II) under controlled conditions (glucose clamp technique). Validation of the blood glucose meters was accomplished by clinically oriented approaches (error grid analysis), statistical approaches (variance components analysis), and by the criteria of the American Diabetes Association (ADA), which recommend a target variability of < 5%. RESULTS: A total of 1,794 blood glucose monitor readings and 299 reference values ranging from 2.2 to 18.2 mmol/l were analyzed (705 readings < 3.89 mmol/l, 839 readings between 3.89 and 9.99 mmol/l, and 250 readings > 9.99 mmol/l). According to error grid analysis, only Reflolux S and Glucocard M had 100% of estimations within the clinically acceptable zones A and B. Assessment of analytical accuracy revealed substantial differences between the glucose meters after separation of the data into defined glycemic ranges. None of the devices met the ADA criteria. CONCLUSIONS: To evaluate accuracy of blood glucose meters, error grid analysis, as well as statistical models, are helpful means and should be performed together. Analytical performance of currently available home blood glucose meters differs substantially within defined glycemic ranges.


Subject(s)
Blood Glucose Self-Monitoring/instrumentation , Diabetes Mellitus, Type 1/blood , Blood Glucose Self-Monitoring/standards , Humans , Quality Control , Reference Values , Regression Analysis , Reproducibility of Results
10.
Biosens Bioelectron ; 13(12): 1271-8, 1998 Dec 01.
Article in English | MEDLINE | ID: mdl-9883561

ABSTRACT

The objective of the study was to evaluate the performance of an amperometric enzyme based lactate sensor and to investigate the possibility of replacing a double lumen catheter based blood withdrawal system with a heparin coated single lumen system. The inner lumen of a double lumen catheter which was placed in a peripheral vein was perfused with heparin solution. The outer lumen was used to collect heparinized blood samples at a defined flow rate. The single lumen system was attached to a heparinized catheter which was also placed in a peripheral vein. The undiluted blood samples were collected at a specified flow rate. A sensor flow chamber incorporating an amperometric thin-film lactate microbiosensor was placed in the sampling line for real-time lactate monitoring. Plasma lactate concentrations were measured during frequently performed hyperlactatemia bicycle ergometer experiments in six healthy volunteers (age 25.8 +/- 2.8 years, BMI 22.7 +/- 1 kg/m2). Additionally, plasma lactate was measured in real-time using the lactate sensors. The first three experiments were performed with a double lumen based catheter system whereas the following three experiments were performed with a heparin coated catheter system. The correlation coefficients of sensor readings and laboratory analyzer results in all six experiments were between 0.93 and 0.99, respectively (P < 0.001). The miniaturized lactate sensors showed a linear range up to 25 mmol/l lactate concentration and 95% response times < 30 s in undiluted serum. During the experiments maximum lactate concentrations of 14 mmol/l were achieved. Improvements of system performance using heparin coated catheter systems could be shown. The overall SD of the sensor readings compared to laboratory results using three double lumen catheter based systems was 0.91 mmol/l whereas the SD using three heparin coated systems was 0.65 mmol/l. In summary, real-time monitoring of lactate in human whole blood is feasible with such a device and can be improved by using heparin coated catheter systems.


Subject(s)
Biosensing Techniques , Lactic Acid/blood , Adult , Heparin/pharmacology , Humans , Male