Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 56(17): 4911-4916, 2017 Jun 10.
Article in English | MEDLINE | ID: mdl-29047634

ABSTRACT

This work introduces a passive dipole antenna integrated into the packaging of a slab-coupled optical sensor to enhance the directional sensitivity of electro-optic electric field measurements parallel to the fiber axis. Using the passive integrated dipole antenna described in this work, a sensor that can typically only sense fields transverse to the fiber direction is able to sense a 1.25 kV/m field along the fiber direction with a gain of 17.5. This is verified through simulation and experiment.

2.
Appl Opt ; 56(24): 6814-6821, 2017 Aug 20.
Article in English | MEDLINE | ID: mdl-29048020

ABSTRACT

Voltage in a coaxial cable is measured by an electric-field optical fiber sensor exploiting the proportionality of voltage and electric field in a fixed structure. The sensor is inserted in a hole drilled through the dielectric of the RG-218 coaxial cable and sealed with epoxy to displace all air and prevent the adverse effects of charge buildup during high-voltage measurements. It is shown that the presence of the sensor in the coaxial cable does not significantly increase electrical reflections in the cable. A slab-coupled optical fiber sensor (SCOS) is used for its compact size and dielectric make. The dynamic range of 50 dB is shown experimentally with detection of signals as low as 1 V and up to 157 kV. A low corner of 0.3 Hz is demonstrated and the SCOS is shown to be able to measure 90 ns rise time.

3.
Appl Opt ; 55(31): 8848-8854, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-27828284

ABSTRACT

A new device structure used for slab-coupled optical sensor (SCOS) technology was developed to fabricate electric field sensors. This new device structure replaces the D-fiber used in traditional SCOS technology with a side-polished Panda fiber. Unlike the D-fiber SCOS, the Panda fiber SCOS is made from commercially available materials and is simpler to fabricate. The Panda SCOS interfaces easier with lab equipment and exhibits ∼3 dB less loss at link points than the D-fiber SCOS. The optical system for the D-fiber is bandwidth limited by a transimpedance amplifier (TIA) used to amplify to the electric signal. The Panda SCOS exhibits less loss than the D-fiber and, as a result, does not require as high a gain setting on the TIA, which results in an overall higher bandwidth range. Results show that the Panda sensor also achieves comparable sensitivity results to the D-fiber SCOS. Although the Panda SCOS is not as sensitive as other side-polished fiber electric field sensors, it can be fabricated much easier because the fabrication process does not require special alignment techniques, and it is made from commercially available materials.

4.
Appl Opt ; 55(25): 7179-85, 2016 Sep 01.
Article in English | MEDLINE | ID: mdl-27607299

ABSTRACT

The development and validation of a high-speed, full-spectrum measurement technique is described for fiber Bragg grating (FBG) sensors. A FBG is surface-mounted to a split-Hopkinson tensile bar specimen to induce high strain rates. The high strain gradients and large strains that indicate material failure are analyzed under high strain rates up to 500 s-1. The FBG is interrogated using a high-speed full-spectrum solid-state interrogator with a repetition rate of 100 kHz. The captured deformed spectra are analyzed for strain gradients using a default interior point algorithm in combination with the modified transfer matrix approach. This paper shows that by using high-speed full-spectrum interrogation of an FBG and the modified transfer matrix method, highly localized strain gradients and discontinuities can be measured without a direct line of sight.

5.
Appl Opt ; 55(3): 603-10, 2016 Jan 20.
Article in English | MEDLINE | ID: mdl-26835936

ABSTRACT

A fiber-optic electric field sensor was developed to measure electric field up to 18 MV/m. The sensor uses resonant coupling between an optical fiber and a nonlinear electro-optical crystal. The sensing system uses high dielectric strength materials to eliminate dielectric breakdown. A postprocessing nonlinear calibration method is developed that maps voltage change to wavelength shift and then converts the wavelength shift to electric field using the transmission spectrum. The nonlinear calibration method is compared against the linear method with electric field pulses having magnitudes from 1.5 to 18 MV/m.

6.
Appl Opt ; 54(16): 5203-9, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-26192684

ABSTRACT

Vibration-insensitive fiber optic electric field sensor is created by fabricating two sensing elements in close proximity onto the same optical fiber and subtracting the two signals. The device is used to measure an electric field of 10 kV/m, while the sensor is being bent and impacted.

SELECTION OF CITATIONS
SEARCH DETAIL
...