Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Orthop Surg Traumatol ; 34(2): 919-925, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37776393

ABSTRACT

PURPOSE: To evaluate the clinical and radiographic outcomes of anterior cruciate (ACL) reconstruction at minimum 10-year follow-up. METHODS: Ninety-three patients who underwent primary unilateral ACL reconstruction with hamstring tendon autograft, transtibial technique and femoral cortico-cancellous screw suspension device (Athrax, Leader Medica s.r.l) between 2010 and 2012 were retrospectively reviewed. Mean follow-up was 136 months. Evaluation was performed using the International Knee Documentation Committee score (IKDC), Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm Knee Score and Tegner Activity Level Scale. Incidence of OA was determined by comparing standard anteroposterior and lateral weightbearing radiographs of the ACL-reconstructed and contralateral knee. Osteoarthritis severity was graded according to the Kellgren-Lawrence (KL) score. RESULTS: Median Tegner activity level was 6 (5-7). Lysholm and IKDC scores were 100 (95-100) and 90 (86-95), respectively, KOOS was 98 (95-100). Of ACL-reconstructed knees, 41 (50%) had radiographic OA, of which 6 (7.3%) had severe OA (KL III). Of the contralateral healthy knees, 28 (34.1%) had radiographic evidence of OA. Of these 22 (26.8%) and 6 (7.3%) patients had, respectively, KL-I and KL-II. 11 patients (11.8%) underwent subsequent knee surgery: 5 (5.4%) revisions, 3 (3.2%) meniscal surgeries, 2 (2.2%) other surgeries, 1 (1.1%) contralateral ACL reconstruction. CONCLUSIONS: The study demonstrates that ACL reconstruction with HT autograft and cortico-cancellous screw suspension device determines satisfying clinical results after 10 years of follow-up. From our cohort, a low rate of graft failure has been reported, even though almost 50% of patients present a knee OA greater or equal to grade II KL.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Hamstring Tendons , Osteoarthritis, Knee , Humans , Hamstring Tendons/transplantation , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Injuries/complications , Retrospective Studies , Autografts , Osteoarthritis, Knee/surgery , Anterior Cruciate Ligament Reconstruction/methods , Bone Screws/adverse effects , Follow-Up Studies
3.
J Child Orthop ; 15(3): 194-203, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-34211595

ABSTRACT

PURPOSE: Biodegradable implants are of major interest in orthopaedics, especially in the skeletally immature population. Magnesium (Mg) implants are promising for selected surgical procedure in adults, but evidence is lacking. Thus, the aim of this study is to analyze the safety and efficacy of resorbable Mg screw in different orthopaedic procedures in skeletally immature patients. In addition, we present a systematic review of the current literature on the clinical use of Mg implants. METHODS: From 2018 until the writing of this manuscript, consecutive orthopaedic surgical procedures involving the use of Mg screws performed at our centre in patients < 15 years of age were retrospectively reviewed. In addition, a systematic review of the literature was performed in the main databases. We included clinical studies conducted on humans, using Mg-alloy implants for orthopaedic procedures. RESULTS: A total of 14 patients were included in this retrospective analysis. Mean age at surgery was 10.8 years (sd 2.4), mean follow-up was 13.8 months (sd 7.5). Healing was achieved in all the procedures, with no implant-related adverse reaction. No patients required any second surgical procedure. The systematic review evidenced 20 clinical studies, 19 of which conducted on an adult and one including paediatric patients. CONCLUSION: Evidence on resorbable Mg implants is low but promising in adults and nearly absent in children. Our series included apophyseal avulsion, epiphyseal fractures, osteochondritis dissecans, displaced osteochondral fragment and tendon-to-bone fixation. Mg screws guaranteed stable fixation, without implant failure, with good clinical and radiological results and no adverse events. LEVEL OF EVIDENCE: IV - Single cohort retrospective analysis with systematic review.

4.
J Shoulder Elbow Surg ; 30(2): 352-358, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32650085

ABSTRACT

BACKGROUND: Distal biceps brachii tendon (DBBT) rupture is a relatively rare injury. Nonsurgical treatment determines 30%-40% power loss of elbow flexion and up to 50% of forearm supination. Therefore, refixation of the DBBT is recommended. The DBBT is exposed to tension and compression loading. It is known that the tendon under compression might develop fibrocartilaginous metaplasia that improves the resistance to compression but reduces the resistance to tension. To test this hypothesis, the present study evaluated the presence of cartilage in DBBT samples. Furthermore, the present study evaluated the clinical and functional outcomes of anatomic reinsertion through suture anchors in a cohort of patients after 1, 3, and 5 years of follow-up. METHODS: Between 2011 and 2014, 21 patients with DBBT tear underwent a suture anchor reattachment. Histochemical and immunohistochemical analysis of torn samples of DBBT collected at the time of surgical repair were performed to test the presence of cartilage. During the follow-up examination, mobility, elbow radiographs, Mayo Elbow Performance Score, and isokinetic analysis were prospectively evaluated. RESULTS: Fibrocartilage was detected in all tendon samples collected. Two cases of transient paresthesia in the lateral antebrachial cutaneous nerve occurred, but they resolved in 6 weeks. There were no vascular deficits, re-ruptures, radioulnar synostoses, or infective complications at follow-up. Three patients reported loss of supination. Mayo Elbow Performance Score showed good and excellent clinical and functional results. No significant differences about strength and fatigue in flexion-supination were recorded between the surgical and contralateral side at 3 and 5 years of follow-up. Arm dominance influenced supination but not flexion. CONCLUSION: On the basis of our results, we find that the presence of cartilage metaplasia might make the DBBT at higher risk of rupture assuming the compression loading and the hypovascular zone of the tendon. However, concerning the lack of histologic analysis of the healthy DBBT, its role in tendon pathology remains to be clearly defined. The technique of suture anchor reinsertion by a single incision was shown to be safe, with few complications and good functional results at 5 years of follow-up. No significant differences were reported between the injured and noninjured side in terms of flexion and supination isokinetic analysis, whereas arm dominance had a positive effect on supination.


Subject(s)
Suture Anchors , Tendon Injuries , Arm , Follow-Up Studies , Humans , Retrospective Studies , Rupture/surgery , Tendon Injuries/surgery , Tendons , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...