Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 122
Filter
1.
Small ; 20(6): e2305311, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37798936

ABSTRACT

Structural engineering and hybridization of heterogeneous 2D materials can be effective for advanced supercapacitor. Furthermore, architectural design of electrodes particularly with vertical construction of structurally anisotropic graphene nanosheets, can significantly enhance the electrochemical performance. Herein, MXene-derived TiO2 nanocomposites hybridized with vertical graphene is synthesized via CO2 laser irradiation on MXene/graphene oxide nanocomposite film. Instantaneous photon energy by laser irradiation enables the formation of vertical graphene structures on nanocomposite films, presenting the controlled anisotropy in free-standing film. This vertical structure enables improved supercapacitor performance by forming an open structure, increasing the electrolyte-electrode interface, and creating efficient electron transport path. In addition, the effective oxidation of MXene nanosheets by instantaneous photon energy leads to the formation of rutile TiO2 . TiO2 nanoparticles directly generated on graphene enables the effective current path, which compensates for the low conductivity of TiO2 and enables the functioning of an effective supercapacitor by utilizing its pseudocapacitive properties. The resulting film exhibits excellent specific areal capacitance of 662.9 mF cm-2 at a current density of 5 mA cm-2 . The film also shows superb cyclic stability during 40 000 repeating cycles, maintaining high capacitance. Also, the pseudocapacitive redox reaction kinetics is evaluated, showing fast redox kinetics with potential for high-performance supercapacitor applications.

2.
Heliyon ; 9(7): e18061, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37496910

ABSTRACT

Background: Longitudinal personal health record (PHR) provides a foundation for managing patients' health care, but we do not have such a system in the U.S. except for the patients in the Department of Veterans Affairs. Such a gap exists mainly in the rest of the U.S. by the fact that patients' electronic health records are scattered across multiple health care facilities and often not shared due to privacy, security, and business interests concerns from both patients and health care organizations. In addition, patients have ethical concerns related to consent. To patients, data security, privacy, and consent are based on trustfulness, rather than patients' engagement in ensuring only authorized people can view their PHRs with patient-managed granularity. Resolving these challenges is an important step in making longitudinal PHR useful for patient care. Objective: This research aims to design and implement a blockchain-enabled sharing platform prototype for PHR with desired patient-controlled data security, privacy, and consent granularity. Methods: Built upon our prior work of a blockchain-enabled access control (BAC) model, we design a blockchain-enabled sharing platform for PHR with patient-controlled security, privacy, and consent granularity. We further implement the construct by building a prototypical platform among a patient and two typical health care organizations. Health organizations that hold the patient's electronic health records can join the platform with trust based on the validation from the patient. The mutual trust can be established through a rigorous validation process by both the patient and the built-in Hyperledger Fabric blockchain consensus mechanism. Results: We proposed a system trusted by patients and health care providers and constructed a Web-based PHR sharing platform with patient-controlled security, privacy, and consent granularity. We analyzed the system scalability in three aspects and showed millisecond range of performance when simultaneously changing access permissions on hundreds of PHRs. Consent, security and privacy of the model are ensured by the merits of the BAC model. We discovered the current blockchain model limits the system scalability due to using a non-graphical database. A new graphical database is suggested for future improvements. Conclusions: In this research, we report a solution to electronically sharing and managing patients' electronic health records originating from multiple organizations, focusing on privacy, security, and granularity control of consent in the U.S. Specifically, the system protects data security and privacy, and provides auditability, scalability, distributedness, patient consent autonomy, and zero-trust capabilities. The prototypical instantiation of the designed model suggested the feasibility of combining emerging blockchain technology with next generation access control model to tackle a longstanding longitudinal PHR problem.

3.
Diagnostics (Basel) ; 13(7)2023 Mar 23.
Article in English | MEDLINE | ID: mdl-37046433

ABSTRACT

A report published in 2000 from the Institute of Medicine revealed that medical errors were a leading cause of patient deaths, and urged the development of error detection and reporting systems. The field of radiation oncology is particularly vulnerable to these errors due to its highly complex process workflow, the large number of interactions among various systems, devices, and medical personnel, as well as the extensive preparation and treatment delivery steps. Natural language processing (NLP)-aided statistical algorithms have the potential to significantly improve the discovery and reporting of these medical errors by relieving human reporters of the burden of event type categorization and creating an automated, streamlined system for error incidents. In this paper, we demonstrate text-classification models developed with clinical data from a full service radiation oncology center (test center) that can predict the broad level and first level category of an error given a free-text description of the error. All but one of the resulting models had an excellent performance as quantified by several metrics. The results also suggest that more development and more extensive training data would further improve future results.

4.
Radiat Res ; 199(6): 556-570, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37018160

ABSTRACT

After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0-1 Gy), moderately (1-2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.


Subject(s)
Chromosome Aberrations , Radioactive Hazard Release , Humans , Retrospective Studies , Radiometry/methods , Biological Assay/methods , Chromosomes , Dose-Response Relationship, Radiation
5.
Radiat Res ; 199(6): 583-590, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37057978

ABSTRACT

Translocation analysis using fluorescence in situ hybridization (FISH) is the method of choice for dose assessment in case of chronic or past exposures to ionizing radiation. Although it is a widespread technique, unlike dicentrics, the number of FISH-based inter-laboratory comparisons is small. For this reason, although the current Running the European Network of Biological and Physical retrospective Dosimetry (RENEB) inter-laboratory comparison 2021 was designed as a fast response to a real emergency scenario, it was considered a good opportunity to perform an inter-laboratory comparison using the FISH technique to gain further experience. The Bundeswehr Institute of Radiobiology provided peripheral blood samples from one healthy human volunteer. Three test samples were irradiated with blinded doses of 0, 1.2, and 3.5 Gy, respectively. Samples were then sent to the seven participating laboratories. The FISH technique was applied according to the standard procedure of each laboratory. Both, the frequency of translocations and the estimated dose for each sample were sent to the coordinator using a special scoring sheet for FISH. All participants sent their results in due time. However, although it was initially requested to send the results based on the full analysis, evaluating 500 equivalent cells, most laboratories only sent the results based on triage, with a smaller number of analyzed cells. In the triage analysis, there was great heterogeneity in the number of equivalent cells scored. On the contrary, for the full analysis, this number was more homogeneous. For all three samples, one laboratory showed outlier yields compared to the other laboratories. Excluding these results, in the triage analysis, the frequency of translocations in sample no. 1 ranged from 0 to 0.013 translocations per cell, and for samples no. 2 and no. 3 the genomic mean frequency were 0.27 ± 0.03 and 1.47 ± 0.14, with a coefficient of variation of 0.29 and 0.23 respectively. Considering only results obtained in the triage analysis for sample no. 1, all laboratories, except one, classified this sample as the non-irradiated one. For sample no. 2, excluding the outlier value, the mean reported dose was 1.74 ± 0.16 Gy indicating a mean deviation of about 0.5 Gy to the delivered dose of 1.2 Gy. For sample no. 3 the mean dose estimated was 4.21 ± 0.21 Gy indicating a mean deviation of about 0.7 Gy to the delivered dose of 3.5 Gy. In the frame of RENEB, this is the second FISH-based inter-laboratory comparison. The whole exercise was planned as a response to an emergency, therefore, a triage analysis was requested for all the biomarkers except for FISH. Although a full analysis was initially requested for FISH, most of the laboratories reported only a triage-based result. The main reason is that it was not clearly stated what was required before starting the exercise. Results show that most of the laboratories successfully discriminated unexposed and irradiated samples from each other without any overlap. A good agreement in the observed frequencies of translocations was observed but there was a tendency to overestimate the delivered doses. Efforts to improve the harmonization of this technique and subsequent exercises to elucidate the reason for this trend should be promoted.


Subject(s)
Radiometry , Translocation, Genetic , Humans , In Situ Hybridization, Fluorescence/methods , Retrospective Studies , Radiometry/methods , Biological Assay/methods , Chromosome Aberrations
6.
Radiat Res ; 199(6): 571-582, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37057983

ABSTRACT

The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semiautomated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.


Subject(s)
Cytokinesis , Radioactive Hazard Release , Humans , Dose-Response Relationship, Radiation , Cytokinesis/radiation effects , Micronucleus Tests/methods , Biological Assay/methods , Radiometry/methods
7.
Sci Immunol ; 8(82): eade2860, 2023 04 21.
Article in English | MEDLINE | ID: mdl-37083451

ABSTRACT

Inborn errors of TLR3-dependent type I IFN immunity in cortical neurons underlie forebrain herpes simplex virus-1 (HSV-1) encephalitis (HSE) due to uncontrolled viral growth and subsequent cell death. We report an otherwise healthy patient with HSE who was compound heterozygous for nonsense (R422*) and frameshift (P493fs9*) RIPK3 variants. Receptor-interacting protein kinase 3 (RIPK3) is a ubiquitous cytoplasmic kinase regulating cell death outcomes, including apoptosis and necroptosis. In vitro, the R422* and P493fs9* RIPK3 proteins impaired cellular apoptosis and necroptosis upon TLR3, TLR4, or TNFR1 stimulation and ZBP1/DAI-mediated necroptotic cell death after HSV-1 infection. The patient's fibroblasts displayed no detectable RIPK3 expression. After TNFR1 or TLR3 stimulation, the patient's cells did not undergo apoptosis or necroptosis. After HSV-1 infection, the cells supported excessive viral growth despite normal induction of antiviral IFN-ß and IFN-stimulated genes (ISGs). This phenotype was, nevertheless, rescued by application of exogenous type I IFN. The patient's human pluripotent stem cell (hPSC)-derived cortical neurons displayed impaired cell death and enhanced viral growth after HSV-1 infection, as did isogenic RIPK3-knockout hPSC-derived cortical neurons. Inherited RIPK3 deficiency therefore confers a predisposition to HSE by impairing the cell death-dependent control of HSV-1 in cortical neurons but not their production of or response to type I IFNs.


Subject(s)
Encephalitis, Herpes Simplex , Herpes Simplex , Herpesvirus 1, Human , Humans , Cell Death , Encephalitis, Herpes Simplex/genetics , Herpesvirus 1, Human/metabolism , Receptor-Interacting Protein Serine-Threonine Kinases/genetics , Receptors, Tumor Necrosis Factor, Type I , Toll-Like Receptor 3/genetics , Toll-Like Receptor 3/metabolism
8.
J Am Coll Surg ; 236(1): 99-104, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36519913

ABSTRACT

BACKGROUND: The Focused Assessment Sonography in Trauma (FAST) examination is the standard of care for detecting hemoperitoneum in hypotensive blunt trauma patients. A pilot study demonstrated earlier identification of intra-abdominal fluid via FAST after right-sided roll (FASTeR) when compared with the standard FAST. The purpose of this study was to evaluate this phenomenon prospectively in hypotensive blunt trauma patients. STUDY DESIGN: An Eastern Association for the Surgery of Trauma-approved multicenter prospective trial was performed June 2016 to October 2020 at 8 designated trauma centers. Hypotensive adult blunt trauma patients were included. A traditional FAST examination was performed. After this, the secondary survey logroll for back examination was standardized to the patient's right side. A repeat supine right upper quadrant ultrasound view was obtained. The presence or absence of hemoperitoneum was confirmed by CT scan or intraoperative findings. FAST and FASTeR were compared using receiver operating characteristics. The area under the curve was calculated. RESULTS: A total of 182 patients met inclusion criteria. A total of 65 patients (35.7%) had hemoperitoneum on CT scan or intraoperative findings. The sensitivity of FASTeR was 47.7%, and of FAST was 40.0% (p = 0.019). The receiver operating characteristics area under the curve of the FASTeR examination was 0.717 vs 0.687 for the FAST examination (p = 0.091). CONCLUSIONS: Addition of a right upper quadrant view after right-sided roll does improve the sensitivity of the FAST examination while maintaining the standard positive predictive value. We demonstrate a trend that does not reach statistical significance about the overall accuracy. This multicenter prospective trial was underpowered to reveal a statistically significant difference in the overall accuracy as measured by the receiver operating characteristics area under the curve.


Subject(s)
Abdominal Injuries , Wounds, Nonpenetrating , Adult , Humans , Abdominal Injuries/diagnostic imaging , Abdominal Injuries/surgery , Abdominal Injuries/complications , Hemoperitoneum/diagnostic imaging , Hemoperitoneum/etiology , Hemoperitoneum/surgery , Prospective Studies , Pilot Projects , Reproducibility of Results , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/surgery , Wounds, Nonpenetrating/complications , Ultrasonography , Sensitivity and Specificity
9.
Diagnostics (Basel) ; 12(6)2022 May 27.
Article in English | MEDLINE | ID: mdl-35741141

ABSTRACT

The radiology imaging community has been developing computer-aided diagnosis (CAD) tools since the early 1990s before the imagination of artificial intelligence (AI) fueled many unbound healthcare expectations and other industries [...].

10.
Am Surg ; 88(5): 1024-1025, 2022 May.
Article in English | MEDLINE | ID: mdl-35311357

ABSTRACT

Intussusception is uncommon in adults, and usually secondary to a neoplasm. Small bowel obstruction (SBO) is prevalent in adults but rarely due to intussusception. A 55-year-old woman with history of melanoma (four years in remission) presented with abdominal pain and melena. Upper and lower endoscopy was normal. She developed bilious emesis and worsening pain, so she presented to the emergency department. CT abdomen/pelvis identified a SBO with transition point at a small bowel intussusception; she was taken to the operating room. A mid-jejunal intussusception was reduced revealing a mass; resection and primary anastomosis was performed. Final pathology demonstrated a 5.5 cm melanoma, likely metastatic. She required no additional therapy and remains in remission eighteen months later. Intussusception due to metastatic melanoma is rare but should be on the differential for patients with SBO and history of melanoma. Knowledge of this history should prompt consideration for oncologic resection to optimize outcome.


Subject(s)
Intestinal Obstruction , Intussusception , Melanoma , Neoplasms, Second Primary , Skin Neoplasms , Adult , Chronic Disease , Female , Humans , Intestinal Obstruction/surgery , Intussusception/etiology , Intussusception/surgery , Melanoma/complications , Melanoma/surgery , Middle Aged , Skin Neoplasms/complications , Skin Neoplasms/surgery , Syndrome , Melanoma, Cutaneous Malignant
11.
Am Surg ; 88(7): 1534-1536, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35333625

ABSTRACT

Fat embolism syndrome (FES) is a multisystem process predominantly secondary to long bone/pelvic fractures and orthopedic procedures. A 19-year-old man presents after motor vehicle collision with trace right pneumothorax, right grade 3 kidney laceration, left pubic rami, and right femoral shaft fractures. Right femur closed reduction ensued and he underwent intramedullary nailing; his other injuries were managed nonoperatively. Upon awakening in recovery, he was newly aphasic. Despite negative repeat CT brain, he continued to worsen and became tachycardic and hypoxemic. MRI/MRA brain demonstrated innumerable bilateral frontal, parietal, and occipital acute ischemic infarcts in a starfield pattern. Echocardiogram revealed a PFO. With supportive care, he improved and was discharged with planned outpatient PFO closure. One month later, he had complete symptom resolution with return to neurologic baseline. FES is a potentially devastating condition which may include cerebral fat embolism (CFE) with outcomes varying widely from mortality to complete recovery.


Subject(s)
Embolism, Fat , Foramen Ovale, Patent , Fractures, Bone , Intracranial Embolism , Pulmonary Embolism , Adult , Embolism, Fat/diagnosis , Embolism, Fat/etiology , Embolism, Fat/therapy , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/surgery , Fractures, Bone/complications , Humans , Intracranial Embolism/diagnostic imaging , Intracranial Embolism/etiology , Male , Pulmonary Embolism/complications , Young Adult
12.
Br J Anaesth ; 128(1): 207-213, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34688473

ABSTRACT

BACKGROUND: Oxygenation via a high-flow nasal cannula (HFNC) can be an alternative to tracheal intubation during short apnoeic procedures. This randomised, non-inferiority study assessed the efficacy of HFNC compared with tracheal intubation in laryngeal microsurgery. METHODS: Patients (≥20 yr old) undergoing laryngeal microsurgery under general anaesthesia and neuromuscular blockade were randomised to either the HFNC or tracheal intubation groups. The primary endpoint was lowest pulse oxygen saturation (SpO2) during the first 30 min of surgery. Secondary endpoints included incidence of desaturation (SpO2 <95%), hypercarbia (transcutaneous carbon dioxide [CO2] ≥8.7 kPa), and rescue intervention. RESULTS: Amongst 130 patients randomised, 118 were included in the analysis. The lowest SpO2 was 100 (98-100)% in the HFNC group (n=56) and 100 (100-100)% in the tracheal intubation group (n=62), with a mean difference of -1.4% (95% confidence interval: -2.4% and -0.3%), failing to confirm non-inferiority with a non-inferiority margin of 2%. The peak transcutaneous CO2 and end-tidal CO2 at the end of surgery were higher in the HFNC group compared with the tracheal intubation group. Incidences of desaturation, hypercarbia, and rescue intervention were more frequent in patients receiving HFNC compared with tracheal intubation. CONCLUSIONS: HFNC oxygenation was not non-inferior to tracheal intubation for maintaining oxygen saturation during laryngeal microsurgery. Considering more frequent desaturation, hypercarbia, and requirement for rescue intervention compared with tracheal intubation, HFNC should be used with cautious monitoring even for short duration airway surgery. CLINICAL TRIAL REGISTRATION: NCT03629353.


Subject(s)
Intubation, Intratracheal/methods , Laryngeal Diseases/surgery , Microsurgery/methods , Oxygen/administration & dosage , Adult , Aged , Aged, 80 and over , Anesthesia, General/methods , Female , Humans , Male , Middle Aged , Neuromuscular Blockade/methods , Oxygen/metabolism , Pilot Projects , Prospective Studies , Young Adult
13.
Sci Data ; 8(1): 183, 2021 07 16.
Article in English | MEDLINE | ID: mdl-34272388

ABSTRACT

We developed a DICOM dataset that can be used to evaluate the performance of de-identification algorithms. DICOM objects (a total of 1,693 CT, MRI, PET, and digital X-ray images) were selected from datasets published in the Cancer Imaging Archive (TCIA). Synthetic Protected Health Information (PHI) was generated and inserted into selected DICOM Attributes to mimic typical clinical imaging exams. The DICOM Standard and TCIA curation audit logs guided the insertion of synthetic PHI into standard and non-standard DICOM data elements. A TCIA curation team tested the utility of the evaluation dataset. With this publication, the evaluation dataset (containing synthetic PHI) and de-identified evaluation dataset (the result of TCIA curation) are released on TCIA in advance of a competition, sponsored by the National Cancer Institute (NCI), for algorithmic de-identification of medical image datasets. The competition will use a much larger evaluation dataset constructed in the same manner. This paper describes the creation of the evaluation datasets and guidelines for their use.


Subject(s)
Data Anonymization , Image Processing, Computer-Assisted , Neoplasms/diagnostic imaging , Algorithms , Humans , Magnetic Resonance Imaging , Positron-Emission Tomography , Tomography, X-Ray Computed
14.
Pathogens ; 10(4)2021 Apr 16.
Article in English | MEDLINE | ID: mdl-33923733

ABSTRACT

The sole equine herpesvirus 1 (EHV-1) immediate-early protein (IEP) is essential for viral replication by transactivating viral immediate-early (IE), early (E), and late (L) genes. Here, we report that treatment of mouse MH-S, equine NBL6, and human MRC-5 cells with 20 ng/mL of IFN-γ reduced EHV-1 yield by 1122-, 631-, and 10,000-fold, respectively. However, IFN-γ reduced virus yield by only 2-4-fold in mouse MLE12, mouse L-M, and human MeWo cells compared to those of untreated cells. In luciferase assays with the promoter of the EHV-1 early regulatory EICP0 gene, IFN-γ abrogated trans-activation activity of the IEP by 96% in MH-S cells, but only by 21% in L-M cells. Similar results were obtained in assays with the early regulatory UL5 and IR4 promoter reporter plasmids. IFN-γ treatment reduced IEP protein expression by greater than 99% in MH-S cells, but only by 43% in L-M cells. The expression of IEP and UL5P suppressed by IFN-γ was restored by JAK inhibitor treatment, indicating that the inhibition of EHV-1 replication is mediated by JAK/STAT1 signaling. These results suggest that IFN-γ blocks EHV-1 replication by inhibiting the production of the IEP in a cell line-dependent manner. Affymetrix microarray analyses of IFN-γ-treated MH-S and L-M cells revealed that five antiviral ISGs (MX1, SAMHD1, IFIT2, NAMPT, TREX1, and DDX60) were upregulated 3.2-18.1-fold only in MH-S cells.

15.
ACS Appl Mater Interfaces ; 13(3): 4703-4710, 2021 Jan 27.
Article in English | MEDLINE | ID: mdl-33435666

ABSTRACT

Many research groups have been interested in the quartz crystal microbalance (QCM)-based gas sensors due to their superb sensitivity originated from direct mass sensing at the ng level. Despite such high sensitivities observed from QCM sensors, their ability to identify gas compounds still needs to be enhanced. Herein, we report a highly facile method that utilizes microcolumns integrated on a QCM gas-responsive system with enhanced chemical selectivity for sensing and ability to identify volatile organic compound single gases. Graphene oxide (GO) flakes are coated on the QCM electrode to substantially increase the adsorption of gas molecules, and periodic polydimethylsiloxane microcolumns with micrometer-scale width and height were installed on the GO-coated QCM electrode. The observed frequency shifts upon sensing of various single gas molecules (such as ethanol, acetone, hexane, etc.) can be analyzed accurately using a simple exponential model. The QCM sensor system with and without the microcolumn both exhibited high detection response values above 50 ng/cm2 for sensing of the gases. Notably, the QCM sensor equipped with the microcolumn features gas identification ability, which is observed as distinct diverging behavior of time constants upon detection of different gases caused by the difference in diffusional transfer of molecules through the microcolumns. For example, the difference in the calculated time constant between ethanol and acetone increased from 22.6 to 92.1 s after installation of the microcolumn. This approach provides an easy and efficient method for identification of single gases, and it may be applied in various advanced sensor systems to enhance their gas selectivity.

17.
World J Clin Cases ; 8(21): 5334-5340, 2020 Nov 06.
Article in English | MEDLINE | ID: mdl-33269267

ABSTRACT

BACKGROUND: Choriocarcinoma is an infrequent entity and the most aggressive subtype of germ-cell tumors. Because of early metastatic spread and rapid disease progression, choriocarcinoma patients display poor prognosis. Although etoposide, methotrexate, actinomycin D, cyclophosphamide, and vincristine (EMA-CO) regimen is widely used to treat gestational trophoblastic tumors in females, its role in treating male choriocarcinoma is seldom reported. CASE SUMMARY: A 32-year-old man was diagnosed with burned-out primary germ cell tumors (GCT) with retroperitoneum, liver and lung metastases. Biopsy of the liver revealed pure choriocarcinoma. The patient received bleomycin, etoposide, and cisplatin chemotherapy. After two cycles of treatment, response evaluation revealed the mixed response. EMA-CO regimen was used in the second-line therapy. After eight cycles, the patient showed a potentially resectable state and thus, all residual masses were surgically removed. The patient was completely cured, and 10 years later, he is leading a healthy life without complications. CONCLUSION: This paper is the first case of high-risk nonseminomatous GCT in a male patient to be successfully treated with the EMA-CO regimen. The EMA-CO regimen can be used actively in patients with high-risk nonseminomatous GCT.

18.
Syst Med (New Rochelle) ; 3(1): 22-35, 2020.
Article in English | MEDLINE | ID: mdl-32226924

ABSTRACT

The First International Conference in Systems and Network Medicine gathered together 200 global thought leaders, scientists, clinicians, academicians, industry and government experts, medical and graduate students, postdoctoral scholars and policymakers. Held at Georgetown University Conference Center in Washington D.C. on September 11-13, 2019, the event featured a day of pre-conference lectures and hands-on bioinformatic computational workshops followed by two days of deep and diverse scientific talks, panel discussions with eminent thought leaders, and scientific poster presentations. Topics ranged from: Systems and Network Medicine in Clinical Practice; the role of -omics technologies in Health Care; the role of Education and Ethics in Clinical Practice, Systems Thinking, and Rare Diseases; and the role of Artificial Intelligence in Medicine. The conference served as a unique nexus for interdisciplinary discovery and dialogue and fostered formation of new insights and possibilities for health care systems advances.

20.
ACS Appl Mater Interfaces ; 12(13): 15396-15405, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32148019

ABSTRACT

Perhydropolysilazane (PHPS), an inorganic polymer composed of Si-N and Si-H, has attracted much attention as a precursor for gate dielectrics of thin-film transistors (TFTs) due to its facile processing even at a relatively low temperature. However, an in-depth understanding of the tunable dielectric behavior of PHPS-derived dielectrics and their effects on TFT device performance is still lacking. In this study, the PHPS-derived dielectric films formed at different annealing temperatures have been used as the gate dielectric layer for solution-processed indium zinc oxide (IZO) TFTs. Notably, the IZO TFTs fabricated on PHPS annealed at 350 °C exhibit mobility as high as 118 cm2 V-1 s-1, which is about 50 times the IZO TFTs made on typical SiO2 dielectrics. The outstanding electrical performance is possible because of the exceptional capacitance of PHPS-derived dielectric caused by the limited hydrolysis reaction of PHPS at a low processing temperature (<400 °C). According to our analysis, the exceptional dielectric behavior is originated from the electric double layer formed by mobile of protons in the low temperature-annealed PHPS dielectrics. Furthermore, proton conduction through the PHPS dielectric occurs through a three-dimensional pathway by a hopping mechanism, which allows uniform polarization of the dielectric even at room temperature, leading to amplified performance of the IZO TFTs.

SELECTION OF CITATIONS
SEARCH DETAIL
...