Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Nanoscale ; 5(11): 4847-54, 2013 Jun 07.
Article in English | MEDLINE | ID: mdl-23616092

ABSTRACT

The elastic response of vertically aligned-carbon nanotube/polydimethylsiloxane (A-CNT/PDMS) nanocomposites is presented in this study and related to the underlying aligned-CNT morphology. Multiwalled carbon nanotubes (MWCNTs) at 1% Vf are embedded in a flexible substrate of PDMS to create a flexible polymer nanocomposite (PNC). The PNC properties are evaluated using scanning electron microscopy (SEM), differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA) and tensile mechanical tests, and the full linearly elastic constitutive relation is established for such a PNC. The results suggest that the CNTs retain the alignment after wetting and curing of PDMS. PDMS is significantly modified by the reinforcing aligned-CNT fibers, demonstrating non-isotropic (as opposed to the isotropic neat PDMS) elastic properties all different from PDMS (Young's modulus of 0.8 MPa), including an anisotropy ratio of 4.8 and increases in the modulus of A-CNT/PDMS over PDMS by more than 900% and 100%, in the CNT longitudinal and transverse directions, respectively. This study reports the first full constitutive relation that may be useful in modeling PNCs as composites or as elements of hierarchical nanoengineered composites, particularly PDMS-CNT PNCs are envisioned as elements in biomedical devices such as pressure transducers and energy harvesters.


Subject(s)
Dimethylpolysiloxanes/chemistry , Nanotubes, Carbon/chemistry , Calorimetry, Differential Scanning , Elastic Modulus , Elasticity , Electric Conductivity , Nanocomposites/chemistry , Polymers/chemistry
2.
Article in English | MEDLINE | ID: mdl-22254360

ABSTRACT

A new approach for the design and fabrication of a highly flexible blood pressure sensor is introduced in this paper. The goal is to measure the pressure within an aneurysm sac for post-endovascular aneurysms repair (EVAR) surveillance. Biocompatible polydimethylsiloxane (PDMS) membranes with embedded aligned carbon nanotubes (CNTs) are used to build the conductive elements of the pressure sensitive capacitor and the inductor for telemetry. Inductive coupling will be used to measure the internal capacitive variations. Fabricated test sensors validate the approach and demonstrate that CNTs/PDMS technology can be used to build highly flexible pressure sensors.


Subject(s)
Blood Pressure Determination/instrumentation , Prostheses and Implants , Telemetry/instrumentation , Transducers, Pressure , Elastic Modulus , Equipment Design , Equipment Failure Analysis , Miniaturization , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...