Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Ter ; 171(5): e385-e392, 2020.
Article in English | MEDLINE | ID: mdl-32901779

ABSTRACT

BACKGROUND: Marginal bone loss (MBL) represents an important indicator of peri-implant health and the measure of its level is considered a determining factor in the evaluation of the quality of survival. Aim of this study is to compare radiographic changes in the fractal and mesial/distal vertical dimensions of peri-implant trabecular bone of dental implants with a laser-ablated micron-scale modication (LAM) of collar surface after a 5-year follow-up period. MATERIALS AND METHODS: Thirty-four implants with LAM of collar surface (test group = TG) and 31 implants without LAM of collar surface (control group = CG) were placed in 45 non-smoking, periodontally healthy patients. Fractal and vertical dimensions of peri-implant trabecular bone were measured by comparing radiographs taken immediately after prosthesis delivery with those taken 3 years and 5 years after functional loading. RESULT: At the end of the 5-year follow-up, the MBL in the TG was 0.87±0.21 and 0.75±0.25 mm at the mesial and distal aspects, respectively, while a MBL of 2.05±0.25 mm at the mesial aspect and 2.01±0.34 mm at the distal site was recorded in the CG. A statistically significant difference was noted. In the TG the mean fractal dimension before loading was 1.4213±0.0525. It increased significantly to 1.4329±0.0479 at 3 years after loading and remained almost stable at 5 years after loading (1.4327±0.0291). In the CG the mean fractal dimension before loading was 1.4119±0.0414. It increased significantly to 1.4282±0.0324 at 3 years after loading and decreased significantly to 1.4111±0.0624 at 5 years after loading. At the end of the follow-up, differences between both study groups were statistically significant. CONCLUSION: The increased fractal dimension and the reduced MBL around TG implants after 5 years of functional loading indicates a positive effect of a laser-ablated micron-scale modication of collar surface on peri-implant trabecular bone remodeling.


Subject(s)
Cancellous Bone/surgery , Dental Implants , Laser Therapy , Adult , Cancellous Bone/diagnostic imaging , Female , Follow-Up Studies , Fractals , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Surface Properties
2.
Int Endod J ; 52(5): 737-745, 2019 May.
Article in English | MEDLINE | ID: mdl-30444531

ABSTRACT

AIM: To compare two different clinical techniques when using endodontic rotary instruments by monitoring the torque in vivo. METHODOLOGY: Ten single-rooted maxillary anterior teeth were prepared by an endodontist using size 25, .06 taper TF rotary instruments (KerrEndo, Orange, CA, USA). All instruments were rotated at 500 rpm with maximum torque set at 2.5 N cm using an endodontic motor (Kavo, Biberach, Germany), which automatically recorded the torque values every 1/10 of a second. Instruments were used with two modi operandi: (i) Inward action: short-length intermittent progression with slight apical pressure aiming to reach the working length (also known as pecking motion), followed by (ii) Outward action: lateral brushing action selectively directed to address the canal circumference whilst removing instruments in the coronal direction. The mean, maximum and accumulated torque values were recorded and analysed statistically (t-test and Wilcoxon test) with a significance level set at 5%. None of the recorded values exceeded the selected torque limit. RESULTS: A significant difference between inward and outward actions was found regarding the evaluated parameters (P < 0.05). The outward action (brushing) was significantly safer (requiring less torque) compared to the inward action (pecking). CONCLUSIONS: Torque measurements during in vivo instrumentation provided useful information regarding the techniques evaluated. Although the torque limit was not reached by any of the two actions, the technique impacted significantly on the torque applied to the instrument.


Subject(s)
Nickel , Root Canal Preparation , Equipment Design , Germany , Titanium , Torque
3.
Clin Ter ; 169(3): e96-e101, 2018.
Article in English | MEDLINE | ID: mdl-29938739

ABSTRACT

OBJECTIVES: Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones. MATERIAL AND METHODS: 25 ProTaper Next (PTN) nickel-titanium (NiTi) instruments (Maillefer-Dentsply, Baillagues, CH) for each of the following two sizes: X1 (17.04 ) and X2 (25.06) were randomly divided into two groups. The first group (n = 10) immediately under- went to a cyclic fatigue test. The second group (n = 15) was initially used to prepare 15 extracted molar teeth and then subjected to a cyclic fatigue test. Same was done for 25 Horizen (HZ) instruments (Kerr Endodontics, Orange, Ca) for each of the following two sizes: 20.04 and 25.06. Instruments were rotated in curved artificial canal until fracture occurred and times to fracture were recorded. All data were collected and statistically analyzed using a variance test (confidence interval CI = 95%). RESULTS: HZ reached working length more rapidly than PTN, and with less deformations. For the fatigue tests, all the new instruments were significantly more resistant than the used ones. The HZ instru- ments were significantly more resistant in all sizes than PTN, both when new and used instruments were tested. CONCLUSIONS: Since in previous studies ProTaper Next demonstra- ted a better resistance to cyclic fatigue than most of nickel-titanium instruments, Horizen's performance put them in a high rank amongst the most resistant nickel-titanium rotary instruments.


Subject(s)
Dental Alloys/chemistry , Materials Testing , Nickel/chemistry , Titanium/chemistry , Equipment Design , Equipment Failure , Humans , Root Canal Preparation , Rotation
SELECTION OF CITATIONS
SEARCH DETAIL
...