Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 107
Filter
1.
Ann Cardiol Angeiol (Paris) ; 63(5): 327-30, 2014 Nov.
Article in French | MEDLINE | ID: mdl-25281994

ABSTRACT

BACKGROUND AND OBJECTIVE: A first publication of our group demonstrated that implantation of a loop recorder in 30 patients experiencing an unexplained syncope (Medtronic Reveal DX or XT) definitively determined that an arrhythmia was the cause of symptoms in 10 patients (32%). However, we lack the results of a survey evaluating the results of long term follow-up after a loop recorder implantation and the results in case of wider indications of implantation of loop recorders. METHODS AND RESULTS: A device (Medtronic Reveal DX or XT) was implanted in 97 patients between january 2009 and june 2014. During a mean follow-up of 21±19 months, loop recording determined that an arrhythmia was the cause of symptoms in 34 patients (35%). For the management of these arrhythmias, treatments received by patients were a pacemaker implantation in 18 patients (53%), an implantable cardioverter-defibrillator in four patients (12%) and a supraventricular tachycardia ablation (cryo or radiofrequency ablation) in three patients (9%). For nine patients (26%), the arrhythmic events were asymptomatic and didn't justify a specific treatment. The final positive rate of loop monitoring implantation was of 25/97 (26%). The study demonstrated that the positivity of the follow-up was demonstrated after two years of follow-up in 26% of the cases. CONCLUSION: Long-term follow-up of 97 patients implanted by a loop monitor leaded to an interventional rythmology procedure in 26% of the cases. In 26% of patients, loop-monitoring follow-up was positive after a duration of more than two years.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Electrocardiography, Ambulatory/instrumentation , Electrodes, Implanted , Syncope/etiology , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/therapy , Catheter Ablation , Defibrillators, Implantable , Equipment Design , Female , Follow-Up Studies , Health Surveys , Humans , Male , Middle Aged , Young Adult
2.
Nanotoxicology ; 8 Suppl 1: 46-56, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24266793

ABSTRACT

Although nanodiamonds (NDs) appear as one of the most promising nanocarbon materials available so far for biomedical applications, their risk for human health remains unknown. Our work was aimed at defining the cytotoxicity and genotoxicity of two sets of commercial carboxylated NDs with diameters below 20 and 100 nm, on six human cell lines chosen as representative of potential target organs: HepG2 and Hep3B (liver), Caki-1 and Hek-293 (kidney), HT29 (intestine) and A549 (lung). Cytotoxicity of NDs was assessed by measuring cell impedance (xCELLigence® system) and cell survival/death by flow cytometry while genotoxicity was assessed by γ-H2Ax foci detection, which is considered the most sensitive technique for studying DNA double-strand breaks. To validate and check the sensitivity of the techniques, aminated polystyrene nanobeads were used as positive control in all assays. Cell incorporation of NDs was also studied by flow cytometry and luminescent N-V center photoluminescence (confirmed by Raman microscopy), to ensure that nanoparticles entered the cells. Overall, we show that NDs effectively entered the cells but NDs do not induce any significant cytotoxic or genotoxic effects on the six cell lines up to an exposure dose of 250 µg/mL. Taken together these results strongly support the huge potential of NDs for human nanomedicine but also their potential as negative control in nanotoxicology studies.


Subject(s)
Carboxylic Acids/chemistry , Intestines/drug effects , Kidney/drug effects , Liver/drug effects , Lung/drug effects , Nanodiamonds , Cell Line , Flow Cytometry , Humans , Microscopy, Confocal
3.
Ann Cardiol Angeiol (Paris) ; 62(5): 322-5, 2013 Nov.
Article in French | MEDLINE | ID: mdl-24054443

ABSTRACT

OBJECTIVE: Evaluate the diagnostic and prognostic input of head-up tilt test in the exploration of unexplained syncope. METHOD: Between January 2009 and December 2012, all patients undergoing a head-up tilt test for recurrent syncope were studied. Follow-up data were obtained using telephone interviews and medical record reviews. RESULTS: A head-up tilt test was realized in 77 patients (47.8±20years, 53% female) for an exploration of syncope. The tilt test elicited syncope or pre-syncope in 57 patients (74%). The positive response included vaso-vagal syncope in 53 patients and psychogenic syncope in 4 patients. After a mean follow-up of 32±11months (range 6-54months), 90% of patients had not a recurrence of syncope. Of note, the incidence of recurrence was the same regardless of whether the patients had a positive (n=5/48; 10%) or a negative head-up tilt test response (n=2/19; 10%). CONCLUSION: The tilt test has a certain diagnostic value in the exploration of unexplained syncope. Recurrence rate of syncope after a tilt test is low. However, our study suggests no correlation between head-up tilt test results and the likelihood of recurring syncope.


Subject(s)
Psychophysiologic Disorders/diagnosis , Syncope, Vasovagal/diagnosis , Syncope/psychology , Tilt-Table Test , Antihypertensive Agents/administration & dosage , Diuretics/administration & dosage , Female , Follow-Up Studies , France , Humans , Male , Middle Aged , Pacemaker, Artificial , Prognosis , Recurrence
4.
Ann Cardiol Angeiol (Paris) ; 61(5): 331-7, 2012 Nov.
Article in French | MEDLINE | ID: mdl-23062819

ABSTRACT

BACKGROUND AND OBJECTIVE: Despite recent advances in diagnostic procedures, syncope remains unexplained in 15 to 35% of patients. If implantable loop recorder is a validated diagnostic tool for unexplained syncope, results of this strategy are largely issued from randomized studies. We lack the results of surveys. The aim of this study was to report a single center experience with implantable loop recorders, in patients with unexplained syncope. METHODS AND RESULTS: A device (Medtronic Reveal DX or XT) was implanted in 31 patients between January 2009 and January 2012. During a mean follow-up of 10.5±8.5 months, loop recording definitively determined that an arrhythmia was the cause of symptoms in 10 patients (32%). Fourteen patients (45%) experienced syncope or pre-syncope. In eight of the 14 patients with syncope, during follow-up, no arrhythmic diagnosis could be made (one patient has been diagnosed as presenting epilepsy and seven as having hypotensive vasovagal syncope). In six patients, the ILR showed an arrhythmic aetiology. Four other patients presented an abnormal ILR result without symptoms. Diagnosis included sinusal arrest in four patients, bradycardia in one patient, advanced atrioventricular block in two patients, ventricular arrythmias in two patients, and supraventricular tachycardia of 180/min in one patient. Therapy was instituted in all patients, in whom an arrhythmic cause was found except one who refused the therapy (six pacemaker, two implantable cardioverter-defibrillator implantations, and one cryoablation of atrioventricular nodal reentrant tachycardia confirmed by an invasive exploration). CONCLUSION: In this survey, implantable loop recorder implantation led to the diagnosis of an arrhythmic cause in 32% of patients and excluded an arrhythmic cause in 26% of patient with a mean follow-up of 10.5 months.


Subject(s)
Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Pacemaker, Artificial , Syncope/etiology , Syncope/therapy , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Atrioventricular Block/complications , Atrioventricular Block/therapy , Bradycardia/complications , Bradycardia/therapy , Female , Follow-Up Studies , France , Health Care Surveys , Hospitals, General , Humans , Male , Middle Aged , Sick Sinus Syndrome/complications , Sick Sinus Syndrome/therapy , Syncope/diagnosis , Syncope, Vasovagal/complications , Syncope, Vasovagal/therapy , Tachycardia, Supraventricular/complications , Tachycardia, Supraventricular/therapy , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/therapy , Treatment Outcome
5.
Ann Cardiol Angeiol (Paris) ; 61(5): 379-81, 2012 Nov.
Article in French | MEDLINE | ID: mdl-22964083

ABSTRACT

In this article, we report the case of a 61-year-old man who presented a cardiac arrest which has been resuscitated successfully. An early repolarization syndrome has been diagnosed by the ECG recorded the first 3 days after admission. This abnormality disappeared after that. The patient received an implantable cardioverter-defibrillator. Practical messages to the clinician concerning early repolarization are provided in this article.


Subject(s)
Death, Sudden, Cardiac/etiology , Defibrillators, Implantable , Ventricular Fibrillation/complications , Ventricular Fibrillation/therapy , Electrocardiography , Follow-Up Studies , Humans , Male , Middle Aged , Syndrome , Treatment Outcome , Ventricular Fibrillation/diagnosis
6.
Ann Cardiol Angeiol (Paris) ; 60(5): 267-71, 2011 Nov.
Article in French | MEDLINE | ID: mdl-21924701

ABSTRACT

OBJECTIVES: This study was designed to assess the hypothesis that the implantation or the replacement of a cardiac stimulator or defibrillator in patients receiving antiplatelet agents is associated with an increase of the haemorrhagic risk in comparison with patients not receiving antiplatelet agents (control group). METHODS AND RESULTS: We retrospectively included all the patients undergoing pacemaker or ICD implantation or replacement between January 2007 and May 2010. The primary criterion was the incidence of bleeding complications. In our center, 685 patients were implanted in this period. Two hundred and fourteen (31%) were implanted while taking antiplatelet agents, including 164 (24%) taking aspirin, 31 (4%) taking clopidogrel and 19 (3%) taking the combination aspirin plus clopidogrel, while 471 patients (69%) did not receive antiplatelet agents. The primary criteria was the hemorrhagic complications. Complications were noted in 14 patients out of 471 (3%) not taking antiplatelet agents, in 16 patients out of 214 (7.5%) taking an antiplatelet agent (P=0.004). The complications concerned 13 patients out of 164 taking aspirin (7.9%), one patient out of 31 (3.2%) taking clopidogrel and two patients out of 19 taking the combination aspirin plus clopidogrel (10.5%) (P=0.042 for aspirin vs placebo, NS for all other comparisons). In multivariable analysis, the factors associated with an increase of the heamorrhagic complications were the type of implant (ICD) (OR 3,7; P=0.001) and antiplatelet treatment (OR 2,7; P=0.009). CONCLUSION: Pacemaker and ICD implantation or replacement in patients taking antiplatelet agents are associated with an increase of the hemorrhagic risk.


Subject(s)
Aspirin/adverse effects , Defibrillators, Implantable , Pacemaker, Artificial , Platelet Aggregation Inhibitors/adverse effects , Postoperative Hemorrhage/chemically induced , Ticlopidine/analogs & derivatives , Adult , Aged , Aged, 80 and over , Algorithms , Aspirin/administration & dosage , Clopidogrel , Drug Therapy, Combination , France/epidemiology , Humans , Incidence , Length of Stay/statistics & numerical data , Middle Aged , Multivariate Analysis , Platelet Aggregation Inhibitors/administration & dosage , Postoperative Care/methods , Postoperative Hemorrhage/drug therapy , Postoperative Hemorrhage/epidemiology , Retrospective Studies , Risk Assessment , Risk Factors , Ticlopidine/administration & dosage , Ticlopidine/adverse effects
7.
Ann Cardiol Angeiol (Paris) ; 59(5): 255-9, 2010 Nov.
Article in French | MEDLINE | ID: mdl-20883977

ABSTRACT

OBJECTIVES: This study was designed to assess the hypothesis that the implantation or the replacement of a cardiac stimulator or defibrillator in patients receiving oral anticoagulants with an INR≥2 doesn't increase the hemorrhagic risk in comparison with patients for whom the treatment has been interrupted temporarily (INR<2) or with patients not receiving anticoagulants (control group). PATIENTS AND RESULTS: We performed a retrospective chart review of bleeding complications in all patients undergoing pacemaker or ICD implantation or replacement between January 2007 and may 2009. In this cohort, 43 patients (10%) were implanted with an INR≥2 while 36 patients (8%) were implanted with an INR<2 and 352 patients (82%) didn't receive anticoagulants. No complication (0/36) has been observed in patients having an INR<2, while 3/43 (7%) complications have been observed in patients with an INR≥2 and 13/352 (3.7%) in patients in the control group (p=0.3093). Duration of the hospital stay was similar in the three groups: 6.2 days in patients with an INR<2, 6.8 days in the group with an INR≥2 and 6.2days in the control group (p=0.686). CONCLUSION: Pacemaker and ICD implantation or replacement without withdrawing of oral anticoagulants and an INR≥2 was not associated with an increase of the hemorrhagic risk.


Subject(s)
Anticoagulants/adverse effects , Defibrillators, Implantable , Pacemaker, Artificial , Postoperative Hemorrhage/chemically induced , Postoperative Hemorrhage/epidemiology , Administration, Oral , Adult , Aged , Aged, 80 and over , Anticoagulants/administration & dosage , Humans , Middle Aged , Prosthesis Implantation , Retrospective Studies , Risk Factors
8.
Ann Cardiol Angeiol (Paris) ; 59(5): 311-3, 2010 Nov.
Article in French | MEDLINE | ID: mdl-20851379

ABSTRACT

A 59-year-old man was admitted after cardiac arrest with successful reanimation. There was no significant coronary lesion. We conclude to the diagnosis of coronary spasm after the occurrence of a chest pain with anterior ST elevation reversible with intravenous nitrates. One month later, non-invasive methylergometrine test was carried out and complicated by a cardiac arrest due to complete heart block and asystole treated by chest compression, molsidomine and epinephrine. No cardiac event occurred within the following six months. Technique (invasive versus not invasive) and indication of methylergometrine test for the follow-up of severe manifestations of coronary spasm should be better specified in international guidelines.


Subject(s)
Coronary Vasospasm/complications , Coronary Vasospasm/diagnosis , Heart Arrest/etiology , Methylergonovine , Humans , Male , Middle Aged
9.
Ann Cardiol Angeiol (Paris) ; 58(5): 304-9, 2009 Nov.
Article in French | MEDLINE | ID: mdl-19819418

ABSTRACT

Left heart disease is the most common cause of pulmonary hypertension. Increased left-sided filling pressure leads to passive postcapillary venous hypertension. In some patients, pulmonary vasoconstriction and vascular remodeling may lead to a further increase in pulmonary pressure. When precapillary hypertension component is associated to left heart failure, the elevation of pulmonary pressure is out of proportion with left atrial pressure: transpulmonary gradient greater than 12 mmHg (mean pulmonary pressure -- mean capillary pressure) and pulmonary vascular resistance greater than three Wood units. Precapillary pulmonary hypertension is common in severe systolic heart failure. Before cardiac transplantation, increased pulmonary vascular resistance greater than 3,5 Wood units are reported in 19 to 35% of patients. In those patients vasoreactivity tests are performed with inotropic and/or systemic and/or pulmonary agents to determine the risk of right heart failure after transplantation. There is no pulmonary vascular resistance level above which transplantation is contraindicated. Cardiac assistance may be used before and after transplantation when pulmonary hypertension is severe and not reversible with conventional treatment and/or pulmonary vasodilators. The contribution of precapillary PH in diastolic heart failure is not known but can be significant and lead to disproportionate PH particularly in elderly. The precapillary component of pulmonary hypertension could be a therapeutic target for specific pulmonary vasodilators. Until now pharmacological trials has been disappointing and those medications can be dangerous because of increasing blood flow to the pulmonary capillaries with a risk of pulmonary edema when left sided pressure are still elevated.


Subject(s)
Heart Failure/complications , Hypertension, Pulmonary/etiology , Heart Failure/physiopathology , Humans , Vascular Resistance
10.
Ann Cardiol Angeiol (Paris) ; 58(5): 265-71, 2009 Nov.
Article in French | MEDLINE | ID: mdl-19833318

ABSTRACT

AIMS: Perioperative management of anticoagulation in patients referred for pacemaker or cardiac defibrillator implantation isn't consensual. Our objective was to evaluate, in a large cohort, hemorrhagic complications in patients having implantation or replacement of a cardiac pacemaker or defibrillator, and to assess perioperative anticoagulation effect on hemorrhagic risk. METHODS AND RESULTS: A cohort of 461 consecutive patients having implantation or replacement of a cardiac pacemaker or defibrillator has been analyzed. Thirty patients (6,5%) had oral anticoagulants (OAC) switched to heparin/low-molecular-weight heparin, while 76 (16,5%) had their oral anticoagulation disrupted habitually for 48 hours. A total of six over 30 (20%) and two over 76 (2.6%) patients in the bridge and OAC, respectively experienced a pocket hematoma (bridge vs. OAC, p<0.05), while ten over 355 (2.8%) had a pocket hematoma in the control group (bridge vs. control p=0.006). Duration of the hospital stay was longer in the bridge group in comparison with OAC and control groups (9 vs. 7 vs. 6 days, respectively, p=0.006). CONCLUSION: Oral anticoagulation bridging with heparin or low-molecular-weight heparin is associated with a higher risk of pocket hematoma and a longer duration of hospitalization, in comparison with a strategy allowing a temporary disruption of OAC adapted to the thromboembolic risk.


Subject(s)
Anticoagulants/adverse effects , Defibrillators, Implantable , Hematoma/chemically induced , Hemorrhage/epidemiology , Pacemaker, Artificial , Adult , Aged , Aged, 80 and over , Clinical Protocols , Hospitals, Community , Humans , Middle Aged , Perioperative Care , Retrospective Studies , Risk Factors
11.
Ann Cardiol Angeiol (Paris) ; 55(6): 306-14, 2006 Nov.
Article in French | MEDLINE | ID: mdl-17191588

ABSTRACT

Recent studies have demonstrated that cardiac resynchronization therapy diminish morbidity and mortality of patients with heart failure, who remain symptomatic despite an optimal medical treatment and who have a wide QRS. However, 30% of patients are non-responders. Hence, echocardiography constitutes an interesting tool for the diagnosis of asynchrony. Different echocardiographic indices predict response to cardiac resynchronization therapy. In this article, a practical approach is proposed for these patients.


Subject(s)
Cardiac Pacing, Artificial , Echocardiography, Doppler , Heart Failure/diagnosis , Heart Failure/therapy , Europe , Humans , Practice Guidelines as Topic , United States
12.
Ann Cardiol Angeiol (Paris) ; 55(6): 315-20, 2006 Nov.
Article in French | MEDLINE | ID: mdl-17191589

ABSTRACT

Cardiac stimulators and defibrillators dispose of diagnostic capabilities. Home monitoring permits to have information about the cardiac rhythm of the patient and about the function of the pacemaker or the defibrillator. Technical aspects, safety and legal issues of home monitoring are discussed in this article.


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Monitoring, Ambulatory/methods , Pacemaker, Artificial , Equipment Design , Humans , Monitoring, Ambulatory/instrumentation , Monitoring, Ambulatory/trends , Safety , Technology Assessment, Biomedical
13.
Arch Mal Coeur Vaiss ; 96(2): 144-8, 2003 Feb.
Article in French | MEDLINE | ID: mdl-14626739

ABSTRACT

A 68-year old woman was hospitalised because of isolated right heart failure. Doppler echocardiography revealed severe tricuspid regurgitation with thickened, shortened, hypomobile leaflets. Pulmonary valve was thickened with mild pulmonary regurgitation. Mitral and aortic valves were normal. The patient was finally diagnosed with carcinoid heart disease from an isolated ovarian carcinoid cancer without hepatic metastases. Ovarectomy was performed and the patient was considered cured of her cancer. Because of refractory right heart failure, she underwent tricuspid valve replacement with a bioprosthesis. Such cardiovascular manifestations are rarely the presenting symptoms of carcinoid disease. Carcinoid heart disease from ovarian primary cancer is exceptional. In this circumstance, carcinoid cardiac lesions may develop in the absence of hepatic metastases because the venous blood from the ovaries drains into the inferior vena cava without hepatic first past effect. Surgical resection of primary ovarian carcinoid tumor is often curative and the prognosis depends mainly on the cardiac condition. The diagnosis of carcinoid syndrome should be discussed in patients with organic tricuspid regurgitation without left valvular disease.


Subject(s)
Carcinoid Heart Disease/etiology , Carcinoid Tumor/secondary , Ovarian Neoplasms/pathology , Tricuspid Valve Insufficiency/etiology , Aged , Carcinoid Heart Disease/complications , Carcinoid Tumor/diagnosis , Female , Humans , Ovarian Neoplasms/diagnosis , Tricuspid Valve
18.
JAMA ; 277(7): 515-6, 1997 Feb 19.
Article in English | MEDLINE | ID: mdl-9032141
19.
J Rheumatol ; 23(7): 1295-6, 1996 Jul.
Article in English | MEDLINE | ID: mdl-8823711

ABSTRACT

We describe a patient with refractory systemic lupus erythematosus (SLE) who demonstrated complete resolution of all SLE symptoms. He was subsequently found to be infected with the human immunodeficiency virus (HIV-1) and had marked depletion of peripheral CD4 positive T lymphocytes. In addition, while his SLE remained completely inactive, the course of HIV was rapidly progressive, suggesting that retroviral replication may have been enhanced by the underlying state of T cell transactivation characteristic of SLE.


Subject(s)
HIV Infections/immunology , HIV-1 , Immune Tolerance/immunology , Lupus Erythematosus, Systemic/immunology , Lupus Erythematosus, Systemic/virology , Adult , Disease Progression , Humans , Male , T-Lymphocytes/physiology , T-Lymphocytes/virology
20.
Arch Mal Coeur Vaiss ; 89(7): 913-6, 1996 Jul.
Article in French | MEDLINE | ID: mdl-8869254

ABSTRACT

The authors report a case of constrictive pericarditis occurring two years after surgical repair of an atrial septal defect in a 37 year-old-man. The diagnosis was made by right heart catheterisation and magnetic resonance imaging. The special feature of this clinical case was the exclusive localisation of the fibrosis on the visceral pericardium or epicarditis. The outcome was favourable after resection of the visceral pericardium respecting the parietal pericardium. Magnetic resonance imaging and right heart catheterisation performed 6 months after surgery were normal. Constrictive pericarditis is a classical complication of cardiac surgery but relatively rare after repair of an atrial septal defect. Isolated involvement of the visceral pericardium is rare and allows surgical correction by exclusive epicardectomy respecting the parietal pericardium.


Subject(s)
Heart Septal Defects, Atrial/surgery , Pericarditis, Constrictive/etiology , Adult , Cardiac Catheterization , Follow-Up Studies , Humans , Magnetic Resonance Imaging , Male , Pericardiectomy , Pericarditis, Constrictive/diagnosis , Pericarditis, Constrictive/surgery , Pericardium/pathology , Pericardium/surgery , Postoperative Complications , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...