Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Healthc Qual Res ; 33(2): 75-81, 2018.
Article in Spanish | MEDLINE | ID: mdl-29534933

ABSTRACT

OBJECTIVE: To analyse the use of complementary tests and their relationship with safety incidents in hospital emergency departments. METHODOLOGY: An analysis was performed on 935 patients seen in the 9 hospital emergency departments. The source of data used for the detection of incidents were: emergency department clinical record and reports, together with face-to-face observation in the department, plus a telephone survey of the patient or family member at one week after the care. Statistical tests used: The Student t test for quantitative variables, Chi squared test for qualitative variables, and the ANOVA test. RESULTS: A peripheral venous catheter was used in 397 patients (42.4% (95% CI; 39.3-45.5%)), with a variability with significant differences between hospitals (P<.01), with a range of use from 37% to 81.8%. It was also observed that in 23.4% (95% CI; 19.2-27.6%) of the cases, the catheter was not used after the first blood draw. Radiological tests were requested for 351 patients, 37.7% (95% CI; 34.6-40.8%), also with significant differences between hospitals (P<.01), ranging from 24.6 to 65, 1%. Incidents were detected in 95 (10.2%) patients (95% CI; 8.3-12.1%) in the all the study centres. A higher proportion of safety incidents have been observed in patients where peripheral venous catheter has been used (12.8%) than in those in whom they had not been used (8.5%) (P=.03), as well as in patients on whom an x-ray was requested (12.8%) compared to those who did not (8.64%) (P=.04). A longer stay was also observed in cases with an incident (mean 248.9minutes) than in those where there were none (mean 164.1minutes) (P<.001). No statistically significant differences were found in the other parameters studied. CONCLUSION: A relationship was observed between the use of a peripheral venous catheter (many of them without use) and radiological tests and the occurrence of safety incidents in the Emergency Departments.


Subject(s)
Catheterization, Peripheral/adverse effects , Emergency Service, Hospital/statistics & numerical data , Medical Errors/statistics & numerical data , Patient Safety/statistics & numerical data , Radiography/adverse effects , Adult , Analysis of Variance , Catheterization, Peripheral/statistics & numerical data , Chi-Square Distribution , Confidence Intervals , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Radiography/statistics & numerical data , Spain , Triage/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...