Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Phys Med Biol ; 65(24): 245033, 2020 12 18.
Article in English | MEDLINE | ID: mdl-32101808

ABSTRACT

In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on time-of-flight (TOF)-resolved prompt gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in order to build TOF spectra of PG generated in a target presenting an air cavity of variable thickness. Since the measurement was carried out at low beam currents (< 1 proton/bunch) it was possible to reach excellent coincidence time resolutions, of the order of 100 ps (σ). Our goal is to detect possible deviations of the proton range with respect to treatment planning within a few intense irradiation spots at the beginning of the session and then carry on the treatment at standard beam currents. The measurements were limited to 10 mm proton range shift. A Monte Carlo simulation study reproducing the experiment has shown that a 3 mm shift can be detected at 2σ by a single detector of ∼1.4 × 10-3 absolute detection efficiency within a single irradiation spot (∼108 protons) and an optimised experimental set-up.


Subject(s)
Proton Therapy/methods , Gamma Rays , Humans , Monte Carlo Method , Phantoms, Imaging
2.
Radiat Prot Dosimetry ; 166(1-4): 257-60, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25897142

ABSTRACT

The ARRONAX cyclotron is able to deliver alpha particles at 68 MeV. In the frame of radiological research, a new method is studied to infer in situ the deposited dose: it is based on the online measurement of the bremsstrahlung (>1 keV) produced by the interaction of the incident particle with the medium. Experiments are made using bombarded poly(methyl methacrylate) (PMMA)-equivalent water targets in order to characterise this continuous X-ray spectrum. The intensity of the bremsstrahlung spectrum allows for the beam monitoring. A simulation code of the bremsstrahlung has been built, and a good agreement is found with the experimental spectra. With this simulation, it is possible to predict the sensibility of this method: it varies with the target thickness, showing a good sensibility for thin target (<1000 µm) and saturation for thicker ones. Bremsstrahlung spectrum also shows a sensibility on the target's chemical composition.


Subject(s)
Cyclotrons/instrumentation , Models, Theoretical , Polymethyl Methacrylate/radiation effects , Radiobiology , Radiotherapy Planning, Computer-Assisted/instrumentation , Alpha Particles , Computer Simulation , Monte Carlo Method , Photons , Polymethyl Methacrylate/chemistry , X-Rays
3.
Radiat Prot Dosimetry ; 161(1-4): 428-32, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24825916

ABSTRACT

To advance the development of a radiobiological experimental set-up for alpha particle irradiations at the Arronax cyclotron, experiments were performed to get the dose response of Gafchomic EBT2 films for alpha particles at 48.3 MeV. A system has been developed using a thin monitor copper foil and an X-ray spectrometer to measure the beam intensity and to calculate the delivered dose. On the other hand, the authors have irradiated EBT2 films, with 6-MV X rays, to get the dose response of EBT2 films for photons. The dose response curve for alpha particles shows an effect of polymerisation saturation compared with the dose response curve for photons.


Subject(s)
Film Dosimetry/instrumentation , Film Dosimetry/methods , Algorithms , Alpha Particles , Calibration , Cyclotrons , Dose-Response Relationship, Radiation , Equipment Design , Facility Design and Construction , Ions , Photons , Radiation Dosage , Radiation, Ionizing , Spectrophotometry/instrumentation , Spectrophotometry/methods , X-Rays
4.
Appl Opt ; 37(28): 6684-9, 1998 Oct 01.
Article in English | MEDLINE | ID: mdl-18301478

ABSTRACT

An important use of the self-mixing effect inside a frequency-modulated single-mode laser diode is in laser velocimetry and range-finding applications. The optical beam reflected by a target and injected into the laser diode cavity modulated by a reshaped current is mixed with the light inside the cavity, causing variations of the optical output power. A theoretical analysis of this effect is proposed, based on the determination of the beat frequencies of the optical power variations, to improve the accuracy of laser distance measurement. A resolution of ?1.5 mm from 50 cm to 2 m is obtained when thermal effects are taken into account.

SELECTION OF CITATIONS
SEARCH DETAIL