Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Microbiol ; 62(4): e0164923, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38470024

ABSTRACT

Scaling up of newer innovations that address the limitations of the dried blood spot and the logistics of plasma monitoring is needed. We employed a multi-site, cross-sectional assessment of the plasma separation card (PSC) on blood specimens collected from all consenting adults, assenting young and pediatric patients living with HIV from 10 primary healthcare clinics in South Africa. Venous blood for EDTA-plasma samples was collected and analyzed according to the standard of care assay, while collected capillary blood for the PSC samples was analyzed using the Roche COBAS AmpliPrep/Cobas TaqMan (CAP/CTM) HIV-1 Test at the National Reference laboratories. McNemar tests assessed the differences in concordance between the centrifuged plasma and dried plasma spots. The usability of PSC by blood spotting, PSC preparation, and pre-analytical work was assessed by collecting seven-point Likert-scale data from healthcare and laboratory workers. We enrolled 538 patients, mostly adults [n = 515, 95.7% (95% CI: 93.7%-97.1%)] and females [n = 322, 64.2% (95% CI: 60.0%-68.1%)]. Overall, 536 paired samples were collected using both PSC- and EDTA-plasma diagnostics, and 502 paired PSC- and EDTA-plasma samples assessed. Concordance between the paired samples was obtained for 446 samples. Analysis of these 446 paired samples at 1,000 copies per milliliter threshold yielded an overall sensitivity of 87.5% [95% CI: 73.2%-95.8%] and specificity of 99.3% [95% CI: 97.9%-99.8%]. Laboratory staff reported technical difficulties in most tasks. The usability of the PSC by healthcare workers was favorable. For policymakers to consider PSC scale-up for viral load monitoring, technical challenges around using PSC at the clinic and laboratory level need to be addressed. IMPORTANCE: Findings from this manuscript emphasize the reliability of the plasma separation card (PSC), a novel diagnostic method that can be implemented in healthcare facilities in resource-constrained settings. The agreement of the PSC with the standard of care EDTA plasma for viral load monitoring is high. Since the findings showed that these tests were highly specific, we recommend a scale-up of PSC in South Africa for diagnosis of treatment failure.


Subject(s)
HIV Infections , HIV-1 , Adult , Female , Humans , Child , Sensitivity and Specificity , HIV-1/genetics , Viral Load/methods , South Africa , Cross-Sectional Studies , Edetic Acid , Reproducibility of Results , RNA, Viral
2.
BMC Res Notes ; 14(1): 468, 2021 Dec 24.
Article in English | MEDLINE | ID: mdl-34952634

ABSTRACT

OBJECTIVE: The proliferation of false information on COVID-19 mostly through social media is adversely affecting control efforts. The objective of this study was to identify areas where targeted effective messaging can be useful in demystifying misinformation against COVID-19. RESULTS: The study showed high levels of misinformation on COVID-19 in the study area [mean score 2.71; standard deviation (SD) 1.5]. The highest levels of misinformation were observed in Dr. Ruth Segomotsi Mompati district, North West province (mean score: 3.84; SD: 2.1) and Sedibeng district, Gauteng province (mean score: 3.56; SD 1.7). Higher levels of misinformation were reported by those aged 18-24 years (mean score: 3.48; SD: 1.8), and men (mean score: 2.73; SD: 1.8). Across the two provinces, we identified geospatial hot and coldspots of misinformation highlighting the need to implement point of care strategies such as targeted messaging. Findings showed the need for targeted interventions to young people, students, those with low levels of education and the self-employed in the two districts more importantly, as South Africa expands its nationwide vaccination roll-out.


Subject(s)
COVID-19 , Adolescent , Communication , Geography , Humans , Male , SARS-CoV-2 , South Africa
SELECTION OF CITATIONS
SEARCH DETAIL
...