Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Vox Sang ; 112(8): 759-766, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28960338

ABSTRACT

BACKGROUND: Fat present during blood salvage in orthopaedic or cardiac surgery can pose a risk of fat embolism and should be eliminated before transfusion. Based on observations of central fat accumulation at the bottom of Latham bowls, a fat reduction program was developed using two volume displacements, where blood temporarily is removed and respun in the bowl to force the fat through the RBC sediment. MATERIALS AND METHODS: Pooled ABO-matched RBC and FFP were adjusted to a haematocrit of 10%, and human fat tissue added to a concentration of 1·25 vol%. In six experiments, blood was processed with the new-generation cell salvage device CS Elite in a newly developed fat reduction program in bowls of three sizes. Volumetric quantification of fat was performed after centrifugation of blood samples in Pasteur pipettes. From volumes, haematocrits and the concentrations of fat, RBC recovery and fat elimination rates were calculated. RESULTS: Fat removal rates of 93·2 ± 2·8, 97·0 ± 2·1 and 99·6 ± 0·3% were observed with a 70-ml, 125-ml and 225-ml bowl, respectively, and even higher rates when removal rates were calculated one cycle. At the same time, high RBC recovery and plasma elimination rates were maintained, not significantly different to the default program mode. CONCLUSION: Modifications in process parameters and sequence led to a fat reduction program that significantly improves fat removal with the Cell Saver Elite from 77·4 ± 5·1% in the default mode to an average of 98·6 ± 1·1%, yielding results equivalent to the continuous cell salvage system (C.A.T.S).


Subject(s)
Blood Safety , Lipids/isolation & purification , Blood Transfusion, Autologous , Erythrocyte Transfusion , Hematocrit , Humans , Lipids/blood
2.
Transfus Med ; 27(4): 292-299, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28524547

ABSTRACT

BACKGROUND AND OBJECTIVES: Cell salvage plays a key role in blood conservation. To maintain high performance, quality management is recommended. Accordingly, a new-generation autotransfusion device was tested for its performance and compared with its predecessor. Two different calculations of quality parameters were applied. MATERIALS AND METHODS: In an experimental study, the continuous autotransfusion devices CATSmart and Continuous Autotransfusion System (C.A.T.S) plus were tested using banked blood adjusted to a haematocrit of 20% and anticoagulated with heparin 5 U/L. Test blood was processed using an emergency programme, a high-quality programme/smart wash programme and a low-volume wash programme. Samples were taken after the production of 200 mL of red blood cells (RBC) and after the final emptying of the separation chamber. In an additional set of tests, blood containing 1·25% fat was processed with both devices to examine fat removal. RESULTS: Both devices demonstrated an equally high performance with regards to product hematocrit (Hct); RBC recovery; and elimination rates of protein, heparin and fat. The high fat elimination rate (>99·8%) reported for C.A.T.S plus was confirmed for CATSmart, regardless of the used programme. Samples taken during the ongoing process show a higher haematocrit and RBC recovery rate than samples taken after the final emptying of the separation chamber. Interface sensors were not affected by fat in the blood. CONCLUSIONS: The new-generation autotransfusion device CATSmart is not inferior to its predecessor and shows high performance with regards to RBC recovery, plasma and fat elimination in all programme modes. Samples for quality controls should be taken during blood processing.


Subject(s)
Blood Transfusion, Autologous/instrumentation , Erythrocytes , Lipids , Quality Control , Blood Transfusion, Autologous/methods , Hematocrit , Humans
SELECTION OF CITATIONS