Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 10(13)2021 Jun 24.
Article in English | MEDLINE | ID: mdl-34202731

ABSTRACT

(1) Background: In the current context of the COVID-19 crisis, there is a need for fast, easy-to-use, and sensitive diagnostic tools in addition to molecular methods. We have therefore decided to evaluate the performance of newly available antigen detection kits in "real-life" laboratory conditions. (2) Methods: The sensitivity and specificity of two rapid diagnostic tests (RDT)-the COVID-19 Ag Respi-Strip from Coris Bioconcept, Belgium (CoRDT), and the coronavirus antigen rapid test cassette from Healgen Scientific, LLC, USA (HeRDT)-were evaluated on 193 nasopharyngeal samples using RT-PCR as the gold standard. (3) Results: The sensitivity obtained for HeRDT was 88% for all collected samples and 91.1% for samples with Ct ≤ 31. For the CoRDT test, the sensitivity obtained was 62% for all collected samples and 68.9% for samples with Ct ≤ 31. (4) Conclusions: Despite the excellent specificity obtained for both kits, the poor sensitivity of the CoRDT did not allow for its use in the rapid diagnosis of COVID-19. HeRDT satisfied the World Health Organization's performance criteria for rapid antigen detection tests. Its high sensitivity, quick response, and ease of use allowed for the implementation of HeRDT at the laboratory of the University Hospital of Liège.

2.
Res Vet Sci ; 136: 343-350, 2021 May.
Article in English | MEDLINE | ID: mdl-33770524

ABSTRACT

Steroid concentrations in serum are fluctuating during pregnancy of many mammal species. The current knowledge about endocrinology of gestation is mainly based on immunoassays. However, the lack of specificity of these assays hampers the reliability of the results. In the present work, we developed and validated a methodology associating liquid chromatography (LC) and mass spectrometry (MS) to simultaneously quantify, with high specificity and accuracy, estrone-3-sulfate (E3S), progesterone (PRO), estrone (E1) and estradiol (E2) in serum of two different mammal species. The sample preparation procedure is based on a simple protein precipitation and a derivatization with dansyl chloride. After the chromatographical separation, compounds were analyzed with a triple-quadrupole mass spectrometer operating in multiple reaction monitoring. Mare and American bison serum samples were analyzed with the validated method and results were compared with concentrations measured with commercial radioimmunoassay (RIA), enzyme linked immunosorbent assay (ELISA) and chemiluminescent microparticle immunoassay (CMIA). Following these criterions: relative standard deviation <15% and relative bias <15%, lower limits of quantification of 0.5 ng/mL (E3S), 0.1 ng/mL (PRO) and 2 pg/mL (E1 and E2) were achieved. Most of the comparison between immunoassays and LC-MS showed poor correlation and proportional differences. Our LC-MS method is able to simultaneously quantify several steroid hormones with high specificity, accuracy and sensitivity in serum of two different mammal species. Our method constitutes a useful and performant tool for veterinary clinicians and LC-MS should thus be used to update and refine the current knowledge about the endocrinology of pregnancy in mammals.


Subject(s)
Bison/blood , Chromatography, Liquid/veterinary , Estradiol/blood , Estrone/analogs & derivatives , Horses/blood , Progesterone/blood , Tandem Mass Spectrometry/veterinary , Animals , Chromatography, Liquid/methods , Estrone/blood , Female , Pregnancy , Reproducibility of Results , Tandem Mass Spectrometry/methods , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...