Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Neuron ; 95(6): 1381-1394.e6, 2017 Sep 13.
Article in English | MEDLINE | ID: mdl-28910621

ABSTRACT

Understanding the detailed dynamics of neuronal networks will require the simultaneous measurement of spike trains from hundreds of neurons (or more). Currently, approaches to extracting spike times and labels from raw data are time consuming, lack standardization, and involve manual intervention, making it difficult to maintain data provenance and assess the quality of scientific results. Here, we describe an automated clustering approach and associated software package that addresses these problems and provides novel cluster quality metrics. We show that our approach has accuracy comparable to or exceeding that achieved using manual or semi-manual techniques with desktop central processing unit (CPU) runtimes faster than acquisition time for up to hundreds of electrodes. Moreover, a single choice of parameters in the algorithm is effective for a variety of electrode geometries and across multiple brain regions. This algorithm has the potential to enable reproducible and automated spike sorting of larger scale recordings than is currently possible.


Subject(s)
Action Potentials/physiology , Algorithms , Neurons/physiology , Signal Processing, Computer-Assisted , Software , Animals , Automation , Brain/physiology , Male , Rats
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 1528-1531, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28268617

ABSTRACT

High-density electrocorticography (ECoG) arrays are promising interfaces for high-resolution neural recording from the cortical surface. Commercial options for high-density arrays are limited, and historically tradeoffs must be made between spatial coverage and electrode density. However, thin-film technology is a promising alternative for generating electrode arrays capable of large area coverage and high channel count, with resolution on the order of cortical columns in the functional surface unit of a human gyrus. Here, we evaluate the sensing performance of a high-density thin-film 128-electrode array designed specifically for recording the distributed neural activity of a single human cortical gyrus. We found robust field potential responses throughout the superior temporal gyrus evoked by speech sounds, and clear phonetic feature selectivity at the resolution of 2 mm inter-electrode distance. Decoding accuracy improved with increasing density of electrodes over all three patients tested. Thin-film ECoG has significant potential for high-density neural interface applications at the scale of a human gyrus.


Subject(s)
Electrocorticography , Cerebral Cortex , Electrodes, Implanted , Electroencephalography , Humans
3.
Article in English | MEDLINE | ID: mdl-25571565

ABSTRACT

The brain is a massively interconnected network of specialized circuits. Even primary sensory areas, once thought to support relatively simple, feed-forward processing, are now known to be parts of complex feedback circuits. All brain functions depend on millisecond timescale interactions across these brain networks. Current approaches cannot measure or manipulate such large-scale interactions. Here we demonstrate that polymer-based, penetrating, micro-electrode arrays can provide high quality neural recordings from awake, behaving animals over periods of months. Our results indicate that polymer electrodes are a viable substrate for the development of systems that can record from thousands of channels across months to years. This is our first step towards developing a 1000+ electrode system capable of providing high-quality, long-term neural recordings.


Subject(s)
Brain Mapping/methods , Electrodes, Implanted , Neurons/pathology , Polymers/chemistry , Signal Processing, Computer-Assisted , Animals , Animals, Genetically Modified , Brain/physiology , Electrophysiology/methods , Equipment Design , Rats , Rats, Long-Evans , User-Computer Interface
4.
Article in English | MEDLINE | ID: mdl-25569992

ABSTRACT

We report a novel method to fabricate chronic neural interfaces with the intent to combine the reliability and lifetime of bulk metal electrodes, with the miniaturization and mechanical flexibility of thin-film polymer microelectrode arrays. 10 µm thick platinum discs were laser cut from a foil into the shape of individual electrodes, and coated with gold on the backside. The discs were bonded to a microelectrode array with gold bond pads via gold-gold inter-diffusion using a flipchip bonder. Electrode bonding and adhesion was characterized using mechanical shear testing and electrical testing. Electrode performance was characterized in vitro using electrochemical impedance spectroscopy and cyclic voltammetry. Biphasic electrical pulsing experiments were conducted on the bonded electrodes to study degradation of the electrode; the preliminary results show that the electrodes can withstand at least 4,900 million pulses with no adverse electrochemical or visual degradation. Overall, this is a promising new method for fabricating chronic neural electrodes for stimulation or recording that combines the reliability of commercial bulk electrodes with the miniaturization and versatility of microfabricated technologies.


Subject(s)
Deep Brain Stimulation/instrumentation , Microelectrodes , Equipment Design
5.
Article in English | MEDLINE | ID: mdl-25571175

ABSTRACT

The translation of advances in neural stimulation and recording research into clinical practice hinges on the ability to perform chronic experiments in awake and behaving animal models. Advances in microelectrode array technology, most notably flexible polymer arrays, have significantly improved reliability of the neural interface. However, electrical connector technology has lagged and is prone to failure from non-biocompatibility, large size, contamination, corrosion, and difficulty of use. We present a novel chronic, percutaneous electrical connector system that is suitable for neural stimulation and recording. This system features biocompatible materials, low connect and disconnect forces, passive alignment, and a protective cap during non-use. We have successfully designed, assembled, and tested in vitro both a 16-channel system and a high density 64-channel system. Custom, polyimide, 16-channel, microelectrode arrays were electrically assembled with the connector system and tested using cyclic voltammetry and electrochemical impedance spectroscopy. This connector system is versatile and can be used with a variety of microelectrode array technologies for chronic studies.


Subject(s)
Microelectrodes , Animals , Electric Stimulation , Electricity , Electrochemistry
6.
J Vis Exp ; (79): e50609, 2013 Sep 27.
Article in English | MEDLINE | ID: mdl-24121443

ABSTRACT

Microelectrode arrays for neural interface devices that are made of biocompatible thin-film polymer are expected to have extended functional lifetime because the flexible material may minimize adverse tissue response caused by micromotion. However, their flexibility prevents them from being accurately inserted into neural tissue. This article demonstrates a method to temporarily attach a flexible microelectrode probe to a rigid stiffener using biodissolvable polyethylene glycol (PEG) to facilitate precise, surgical insertion of the probe. A unique stiffener design allows for uniform distribution of the PEG adhesive along the length of the probe. Flip-chip bonding, a common tool used in microelectronics packaging, enables accurate and repeatable alignment and attachment of the probe to the stiffener. The probe and stiffener are surgically implanted together, then the PEG is allowed to dissolve so that the stiffener can be extracted leaving the probe in place. Finally, an in vitro test method is used to evaluate stiffener extraction in an agarose gel model of brain tissue. This approach to implantation has proven particularly advantageous for longer flexible probes (>3 mm). It also provides a feasible method to implant dual-sided flexible probes. To date, the technique has been used to obtain various in vivo recording data from the rat cortex.


Subject(s)
Absorbable Implants , Adhesives/chemistry , Brain/physiology , Microelectrodes , Polyethylene Glycols/chemistry , Animals , Brain/surgery , Mice
7.
Article in English | MEDLINE | ID: mdl-24109995

ABSTRACT

We report a novel nano-cluster platinum (NCPt) film that exhibits enhanced performance as an electrode material for neural stimulation applications. Nano-cluster films were deposited using a custom physical vapor deposition process and patterned on a flexible polyimide microelectrode array using semiconductor processing technology. Electrode performance was characterized in vitro using electrochemical impedance spectroscopy and compared with sputtered thinfilm platinum (TFPt) electrodes. We characterized electrode impedance, charge storage capacity, voltage transient properties, and relative surface area enhancement in vitro. Preliminary lifetime testing of the electrode reveals that the NCPt electrodes degrade more slowly than TFPt electrodes. The combination of material biocompatibility, electrochemical performance, and preliminary lifetime results point to a promising new electrode material for neural interface devices.


Subject(s)
Electric Stimulation/methods , Platinum/chemistry , Electric Impedance , Electrochemical Techniques , Electrodes , Electrons , Microscopy, Electron, Scanning , Microtechnology , Nanoparticles/chemistry , Optical Imaging
8.
Article in English | MEDLINE | ID: mdl-24110897

ABSTRACT

We present here a microfabricated, multi-functional neural interface with the ability to selectively apply electrical and chemical stimuli, while simultaneously monitoring both electrical and chemical activity in the brain. Such a comprehensive approach is required to understand and treat neuropsychiatric disorders, such as major depressive disorder (MDD), and to understand the mechanisms underlying treatments, such as pharmaceutical therapies and deep brain stimulation (DBS). The polymer-based, multi-functional neural interface is capable of electrical stimulation and recording, targeted drug delivery, and electrochemical sensing. A variety of different electrode and fluidic channel arrangements are possible with this fabrication process. Preliminary testing has shown the suitability of these neural interfaces for in vivo electrical stimulation and recording, as well as in vitro chemical sensing. Testing of the in vitro drug delivery and combined in vivo functionalities this neural interface are currently underway.


Subject(s)
Drug Delivery Systems/instrumentation , Electrodes, Implanted , Polymers/chemistry , Brain/physiology , Deep Brain Stimulation/instrumentation , Depressive Disorder, Major , Electric Stimulation/instrumentation , Electrochemistry/instrumentation , Electrochemistry/methods , Equipment Design , Humans , Man-Machine Systems , Microtechnology , Neurons/metabolism
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2012: 5999-6002, 2012.
Article in English | MEDLINE | ID: mdl-23367296

ABSTRACT

We present here a demonstration of a dual-sided, 4-layer metal, polyimide-based electrode array suitable for neural stimulation and recording. The fabrication process outlined here utilizes simple polymer and metal deposition and etching steps, with no potentially harmful backside etches or long exposures to extremely toxic chemicals. These polyimide-based electrode arrays have been tested to ensure they are fully biocompatible and suitable for long-term implantation; their flexibility minimizes the injury and glial scarring that can occur at the implantation site. The creation of dual-side electrode arrays with more than two layers of trace metal enables the fabrication of neural probes with more electrodes without a significant increase in probe size. This allows for more stimulation/recording sites without inducing additional injury and glial scarring.


Subject(s)
Microelectrodes , Neurons/physiology , Electrochemical Techniques , Equipment Design
10.
Article in English | MEDLINE | ID: mdl-23367295

ABSTRACT

We present here a microfabrication process for multi-layer metal, multi-site, polymer-based neural probes. The process has been used to generate 1-, 2-, and 4-layer trace metal neural probes with highly uniform and reproducible electrode characteristics. Typically, increasing the number of metal layers is assumed to both reduce the width of the neural probes and minimize the injury and glial scarring caused at the implantation site. We show, however, that increasing the number of trace metal layers does not always result in the minimal probe cross-sectional area. A thorough design analysis reveals that the electrode size, along with other design parameters, have interacting effects on the probe cross-sectional area. Moreover, increasing the trace metal layers in the neural probes also increases the design and fabrication cost/time, as well as the likelihood of probe failure. Consequently, all of these factors must be considered when designing a multi-site, neural probe with the objective of minimizing tissue damage.


Subject(s)
Biocompatible Materials , Equipment Design , Metals/chemistry , Neurons/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...