Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 123
Filter
1.
Heart Rhythm ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38762820

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure™ defibrillation lead is a novel small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform. OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead. METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively. RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD). CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.

2.
Heart Rhythm ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38763377

ABSTRACT

Youth and adult participation in sports continues to increase, and athletes may be diagnosed with potentially arrhythmogenic cardiac conditions. This international multidisciplinary document is intended to guide electrophysiologists, sports cardiologists, and associated health care team members in the diagnosis, treatment, and management of arrhythmic conditions in the athlete with the goal of facilitating return to sport and avoiding the harm caused by restriction. Expert, disease-specific risk assessment in the context of athlete symptoms and diagnoses is emphasized throughout the document. After appropriate risk assessment, management of arrhythmias geared toward return to play when possible is addressed. Other topics include shared decision-making and emergency action planning. The goal of this document is to provide evidence-based recommendations impacting all areas in the care of athletes with arrhythmic conditions. Areas in need of further study are also discussed.

4.
Pediatr Radiol ; 54(6): 863-875, 2024 05.
Article in English | MEDLINE | ID: mdl-38488925

ABSTRACT

Magnetic resonance imaging (MRI) is now an indispensable diagnostic tool in medicine due to its outstanding contrast resolution and absence of radiation exposure, enabling detailed tissue characterization and three-dimensional anatomical representation. This is especially important when evaluating individuals with congenital heart disease (CHD) who frequently require cardiac implantable electrical devices (CIEDs). While MRI safety issues have previously limited its use in patients with CIEDs, new advances have called these limitations into question. However, difficulties persist in the pediatric population due to the continued lack of specific safety data both related to imaging young children and the specific CIED devices they often require. This paper discusses MRI safety considerations related to imaging patients with CIEDs, investigates pediatric-specific problems, and describes thorough methods for safe MRI access, highlighting the significance of specialized institutional guidelines.


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Magnetic Resonance Imaging , Pacemaker, Artificial , Child , Humans , Contraindications, Procedure , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Imaging/methods , Patient Safety
7.
Heart Rhythm ; 21(5): 581-589, 2024 May.
Article in English | MEDLINE | ID: mdl-38246569

ABSTRACT

BACKGROUND: The Apple Watch™ (AW) offers heart rate (HR) tracking by photoplethysmography (PPG) and single-lead electrocardiographic (ECG) recordings. The accuracy of AW-HR and diagnostic performance of AW-ECGs among children during both sinus rhythm and arrhythmias have not been explored. OBJECTIVE: The purposes of this study were to assess the accuracy of AW-HR measurements compared to gold standard modalities in children during sinus rhythm and arrhythmias and to identify non-sinus rhythms using AW-ECGs. METHODS: Subjects ≤18 years wore an AW during (1) telemetry admission, (2) electrophysiological study (EPS), or (3) exercise stress test (EST). AW-HRs were compared to gold standard modality values. Recorded AW-ECGs were reviewed by 3 blinded pediatric electrophysiologists. RESULTS: Eighty subjects (median age 13 years; interquartile range 1.0-16.0 years; 50% female) wore AW (telemetry 41% [n = 33]; EPS 34% [n = 27]; EST 25% [n = 20]). A total of 1090 AW-HR measurements were compared to time-synchronized gold standard modality HR values. Intraclass correlation coefficient (ICC) was high 0.99 (0.98-0.99) for AW-HR during sinus rhythm compared to gold standard modalities. ICC was poor comparing AW-HR to gold standard modality HR in tachyarrhythmias (ICC 0.24-0.27) due to systematic undercounting of AW-HR values. A total of 126 AW-ECGs were reviewed. Identification of non-sinus rhythm by AW-ECG showed sensitivity of 89%-96% and specificity of 78%-87%. CONCLUSIONS: We found high levels of agreement for AW-HR values with gold standard modalities during sinus rhythm and poor agreement during tachyarrhythmias, likely due to hemodynamic effects of tachyarrhythmias on PPG-based measurements. AW-ECGs had good sensitivity and moderate specificity in identification of non-sinus rhythm in children.


Subject(s)
Arrhythmias, Cardiac , Heart Rate , Photoplethysmography , Humans , Female , Male , Child , Adolescent , Heart Rate/physiology , Child, Preschool , Infant , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Photoplethysmography/methods , Photoplethysmography/instrumentation , Reproducibility of Results , Telemetry/instrumentation , Telemetry/methods , Wearable Electronic Devices , Electrocardiography/methods , Equipment Design , Electrocardiography, Ambulatory/methods , Electrocardiography, Ambulatory/instrumentation , Exercise Test/methods
8.
JACC Clin Electrophysiol ; 10(3): 539-550, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38206260

ABSTRACT

BACKGROUND: Evidence for the efficacy of cardiac resynchronization therapy (CRT) in pediatric and congenital heart disease (CHD) has been limited to surrogate outcomes. OBJECTIVES: This study aimed to assess the impact of CRT upon the risk of transplantation or death in a retrospective, high-risk, controlled cohort at 5 quaternary referral centers. METHODS: Both CRT patients and control patients were <21 years of age or had CHD; had systemic ventricular ejection fraction <45%; symptomatic heart failure; and significant electrical dyssynchrony (QRS duration z score >3 or single-site ventricular pacing >40%) at enrollment. Patients with CRT were matched with control patients via 1:1 propensity score matching. CRT patients were enrolled at CRT implantation; control patients were enrolled at the outpatient clinical encounter where inclusion criteria were first met. The primary endpoint was transplantation or death. RESULTS: In total, 324 control patients and 167 CRT recipients were identified. Mean follow-up was 4.2 ± 3.7 years. Upon propensity score matching, 139 closely matched pairs were identified (20 baseline indices). Of the 139 matched pairs, 52 (37.0%) control patients and 31 (22.0%) CRT recipients reached the primary endpoint. On both unadjusted and multivariable Cox regression analysis, the risk reduction associated with CRT for the primary endpoint was significant (HR: 0.40; 95% CI: 0.25-0.64; P < 0.001; and HR: 0.44; 95% CI: 0.28-0.71; P = 0.001, respectively). On longitudinal assessment, the CRT group had significantly improved systemic ventricular ejection fraction (P < 0.001) and shorter QRS duration (P = 0.015), sustained to 5 years. CONCLUSIONS: In pediatric and CHD patients with symptomatic systolic heart failure and electrical dyssynchrony, CRT was associated with improved heart transplantation-free survival.


Subject(s)
Cardiac Resynchronization Therapy , Heart Defects, Congenital , Heart Failure, Systolic , Heart Transplantation , Humans , Child , Retrospective Studies , Heart Defects, Congenital/therapy , Heart Failure, Systolic/therapy
9.
Card Electrophysiol Clin ; 15(4): 421-432, 2023 12.
Article in English | MEDLINE | ID: mdl-37865516

ABSTRACT

Transcatheter leadless pacemakers have benefits in congenital heart disease because they eliminate the risks of lead malfunction, venous occlusions, and pocket complications. This newest pacemaker's utility in this population has been limited by the large sheath and delivery system, need for atrioventricular synchronous pacing, lack of explantation options, and possible lack of adequate access to the subpulmonary ventricle. With careful planning, leadless pacing can be successfully performed in these patients. Consideration of nonfemoral access, alternative implant sites to avoid myocardial scar or prosthetic material, anticoagulation for patients with persistent intracardiac shunts or systemic ventricular implantation, and operator experience are critical.


Subject(s)
Heart Defects, Congenital , Pacemaker, Artificial , Humans , Cardiac Pacing, Artificial , Heart Ventricles , Heart Defects, Congenital/therapy , Myocardium
11.
Pediatr Cardiol ; 2023 Sep 09.
Article in English | MEDLINE | ID: mdl-37684488

ABSTRACT

Hypertrophic cardiomyopathy (HCM), a common cardiomyopathy in children, is an important cause of morbidity and mortality. Early recognition and appropriate management are important. An electrocardiogram (ECG) is often used as a screening tool in children to detect heart disease. The ECG patterns in children with HCM are not well described.ECGs collected from an international cohort of children, and adolescents (≤ 21 years) with HCM were reviewed. 482 ECGs met inclusion criteria. Age ranged from 1 day to 21 years, median 13 years. Of the 482 ECGs, 57 (12%) were normal. The most common abnormalities noted were left ventricular hypertrophy (LVH) in 108/482 (22%) and biventricular hypertrophy (BVH) in 116/482 (24%) Of the patients with LVH/BVH (n = 224), 135 (60%) also had a strain pattern (LVH in 83, BVH in 52). Isolated strain pattern (in the absence of criteria for hypertrophy) was seen in 43/482 (9%). Isolated pathologic Q waves were seen in 71/482 (15%). Pediatric HCM, 88% have an abnormal ECG. The most common ECG abnormalities were LVH or BVH with or without strain. Strain pattern without hypertrophy and a pathologic Q wave were present in a significant proportion (24%) of patients. Thus, a significant number of children with HCM have ECG abnormalities that are not typical for "hypertrophy". The presence of the ECG abnormalities described above in a child should prompt further examination with an echocardiogram to rule out HCM.

12.
Pediatr Cardiol ; 2023 Aug 06.
Article in English | MEDLINE | ID: mdl-37544951

ABSTRACT

BACKGROUND: Published guidelines provide recommendations for risk stratification in pediatric Wolff-Parkinson-White (WPW). There are no data on provider concordance with these guidelines. We hypothesized that significant practice variation exists between pediatric cardiologists (PC) and electrophysiologists (EP). METHOD: The records of all patients, age 8 to 21 years, with a new ECG diagnosis of WPW between 1/1/2013 and 12/31/2018, from a single center, were retrospectively reviewed. Subjects were categorized on the basis of symptoms and resting ECG findings as one of the following: asymptomatic intermittent WPW, asymptomatic persistent WPW, or symptomatic WPW. The performance and results of diagnostic testing, including Holter monitor, event monitor, exercise stress test (EST), and electrophysiology study (EPS), were recorded. The primary outcome was concordance with published guidelines. A secondary outcome was documentation of a discussion of sudden cardiac death (SCD) risk. RESULTS: 615 patient encounters were analyzed in 231 patients with newly diagnosed WPW pattern on ECG (56% male; mean age at diagnosis 13.9 ± 2.5 years). EP were observed to have a significantly higher rate of guideline concordance than PC (95% vs. 71%, p < 0.001). There was significant practice variation between PC and EP in the documentation of a discussion of SCD risk: 96% in EP vs. 39% in PC (p < 0.001). CONCLUSION: Significant practice variation exists in the non-invasive and invasive risk stratification of pediatric WPW, with lower concordance to published guidelines amongst PC, when compared to EP. This report highlights the need to promote awareness of current WPW guidelines in the pediatric cardiology community at large.

13.
Heart Rhythm ; 20(12): 1752-1758, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37648183

ABSTRACT

BACKGROUND: Guidelines addressing magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) provide algorithms for imaging pediatric and congenital heart disease (CHD) patients. Guideline acceptance varies by institution. Guidelines also do not support routine MRI scans in patients with epicardial or abandoned leads, common in pediatric and CHD patients. OBJECTIVE: The purpose of this study was to determine the incidence of MRI-related complications in pediatric and CHD patients with CIEDs, including epicardial and/or abandoned leads. METHODS: A multicenter retrospective review included patients with CIEDs who underwent any MRI between 2007 and 2022 at congenital cardiac centers. The primary outcome was any patient adverse event or clinically significant CIED change after MRI, defined as pacing lead capture threshold increase >0.5 V with output change, P- or R- wave amplitude decrease >50% with sensitivity change, or impedance change >50%. RESULTS: Across 14 institutions, 314 patients (median age 18.8 [1.3; 31.4] years) underwent 389 MRIs. There were 288 pacemakers (74%) and 87 implantable cardioverter-defibrillators (22%); 52% contained epicardial leads, and 14 (4%) were abandoned leads only. Symptoms or CIED changes occurred in 4.9% of MRI scans (6.1% of patients). On 9 occasions (2%), warmth or pain occurred. Pacing capture threshold or lead impedance changes occurred in 1.4% and 2.0% of CIEDs post-MRI and at follow-up. CONCLUSION: Our data provide evidence that MRIs can be performed in pediatric and CHD patients with CIEDs, including non-MRI-conditional CIEDs and epicardial and/or abandoned leads, with rare minor symptoms or CIED changes but no other complications.


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Pacemaker, Artificial , Adolescent , Child , Humans , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Magnetic Resonance Imaging/methods , Retrospective Studies , Infant , Child, Preschool , Young Adult , Adult
15.
Circ Arrhythm Electrophysiol ; 16(4): e011447, 2023 04.
Article in English | MEDLINE | ID: mdl-37039017

ABSTRACT

BACKGROUND: Transcatheter Leadless Pacemakers (TLP) are a safe and effective option for adults with pacing indications. These devices may be an alternative in pediatric patients and patients with congenital heart disease for whom repeated sternotomies, thoracotomies, or transvenous systems are unfavorable. However, exemption of children from clinical trials has created uncertainty over the indications, efficacy, and safety of TLP in the pediatric population. The objectives of this study are to evaluate clinical indications, procedural characteristics, electrical performance, and outcomes of TLP implantation in children. METHODS: Retrospective data were collected from patients enrolled in the Pediatric and Congenital Electrophysiology Society TLP registry involving 15 centers. Patients ≤21 years of age who underwent Micra (Medtronic Inc, Minneapolis, MN) TLP implantation and had follow-up of ≥1 week were included in the study. RESULTS: The device was successfully implanted in 62 of 63 registry patients (98%) at a mean age of 15±4.1 years and included 20 (32%) patients with congenital heart disease. The mean body weight at TLP implantation was 55±19 kg and included 8 patients ≤8 years of age and ≤30 kg in weight. TLP was implanted by femoral (n=55, 87%) and internal jugular (n=8, 12.6%) venous approaches. During a mean follow-up period of 9.5±5.3 months, there were 10 (16%) complications including one cardiac perforation/pericardial effusion, one nonocclusive femoral venous thrombus, and one retrieval and replacement of TLP due to high thresholds. There were no deaths, TLP infections, or device embolizations. Electrical parameters, including capture thresholds, R wave sensing, and pacing impedances, remained stable. CONCLUSIONS: Initial results from the Pediatric and Congenital Electrophysiology Society TLP registry demonstrated a high level of successful Micra device implants via femoral and internal venous jugular approaches with stable electrical parameters and infrequent major complications. Long-term prospective data are needed to confirm the reproducibility of these initial findings.


Subject(s)
Heart Defects, Congenital , Pacemaker, Artificial , Adult , Humans , Child , Adolescent , Young Adult , Infant, Newborn , Prospective Studies , Retrospective Studies , Reproducibility of Results , Treatment Outcome , Equipment Design , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy
16.
JACC Clin Electrophysiol ; 9(3): 385-393, 2023 03.
Article in English | MEDLINE | ID: mdl-36752449

ABSTRACT

BACKGROUND: Dyssynchrony-associated left ventricular systolic dysfunction is a major contributor to heart failure in congenital heart disease (CHD). Although conventional cardiac resynchronization therapy (CRT) has shown benefit, the comparative efficacy of cardiac conduction system pacing (CSP) is unknown. OBJECTIVES: The purpose of this study was compare the clinical outcomes of CSP vs conventional CRT in CHD with biventricular, systemic left ventricular anatomy. METHODS: Retrospective CSP data from 7 centers were compared with propensity score-matched conventional CRT control subjects. Outcomes were lead performance, change in left ventricular ejection fraction (LVEF), and QRS duration at 12 months. RESULTS: A total of 65 CSP cases were identified (mean age 37 ± 21 years, 46% men). The most common CHDs were tetralogy of Fallot (n = 12 [19%]) and ventricular septal defect (n = 12 [19%]). CSP was achieved after a mean of 2.5 ± 1.6 attempts per procedure (38 patients with left bundle branch pacing, 17 with HBP, 10 with left ventricular septal myocardial). Left bundle branch area pacing [LBBAP] vs HBP was associated with a smaller increase in pacing threshold (Δ pacing threshold 0.2 V vs 0.8 V; P = 0.05) and similar sensing parameters at follow-up. For 25 CSP cases and control subjects with baseline left ventricular systolic dysfunction, improvement in LVEF was non-inferior (Δ LVEF 9.0% vs 6.0%; P = 0.30; 95% confidence limits: -2.9% to 10.0%) and narrowing of QRS duration was more pronounced for CSP (Δ QRS duration 35 ms vs 14 ms; P = 0.04). Complications were similar (3 [12%] CSP, 4 [16%] conventional CRT; P = 1.00). CONCLUSIONS: CSP can be reliably achieved in biventricular, systemic left ventricular CHD patients with similar improvement in LVEF and greater QRS narrowing for CSP vs conventional CRT at 1 year. Among CSP patients, pacing electrical parameters were superior for LBBAP vs HBP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Defects, Congenital , Ventricular Dysfunction, Left , Male , Humans , Adolescent , Young Adult , Adult , Middle Aged , Female , Cardiac Resynchronization Therapy/adverse effects , Bundle-Branch Block , Bundle of His , Stroke Volume , Retrospective Studies , Electrocardiography , Ventricular Function, Left , Treatment Outcome , Cardiac Conduction System Disease , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy , Ventricular Dysfunction, Left/therapy
17.
JACC Clin Electrophysiol ; 9(1): 73-84, 2023 01.
Article in English | MEDLINE | ID: mdl-36697203

ABSTRACT

BACKGROUND: Guidelines for electrophysiology study (EPS) and catheter ablation in Wolff-Parkinson-White (WPW) are age based, but size may be a more relevant factor in determination of outcomes. OBJECTIVES: The goal of this study was to evaluate the association of patient weight with outcomes of catheter ablation for pediatric WPW. METHODS: A multicenter retrospective cohort study was performed on children aged 1 to 21 years with WPW and first-time EPS from April 2016 to December 2019 recorded in the IMPACT (Improving Pediatric and Adult Congenital Treatment) registry, excluding those with congenital heart disease, cardiomyopathy, and >1 ablation target. A weight threshold of 30 kg was selected, representing 1 SD below the cohort mean. The primary outcome was major adverse events (MAEs); additional outcomes included deferred ablation, use of cryoablation, and ablation success. RESULTS: A total of 4,456 subjects from 84 centers were evaluated, with 14% weighing <30 kg. Subjects weighing <30 kg were more likely to have preprocedural supraventricular tachycardia (45% vs 29%; P < 0.001) and less likely to have right septal accessory pathways (25% vs 33%; P < 0.001). MAEs were rare, although with higher incidence in the <30 kg cohort (0.3% vs 0.05%; P = 0.04). No difference was seen in likelihood of deferred ablation (9% vs 12%; P = 0.07) or use of cryoablation (11% vs 11%; P = 0.70). Success was higher in the <30 kg cohort: 95% vs 92% (P = 0.009). This effect persisted after adjusting for covariates (odds ratio: 1.6; 95% CI: 1.01-2.70; P = 0.046). CONCLUSIONS: Weight <30 kg was associated with a small but elevated risk of MAEs. Rates of deferred ablation and cryoablation were similar. Adjusting for factors (including accessory pathway type and location), weight <30 kg remained an independent predictor of acute success.


Subject(s)
Accessory Atrioventricular Bundle , Tachycardia, Supraventricular , Wolff-Parkinson-White Syndrome , Adult , Humans , Child , Wolff-Parkinson-White Syndrome/epidemiology , Wolff-Parkinson-White Syndrome/surgery , Retrospective Studies , Accessory Atrioventricular Bundle/surgery , Registries
18.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Article in English | MEDLINE | ID: mdl-36378803

ABSTRACT

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Subject(s)
Defibrillators, Implantable , Heart Arrest , Humans , Bayes Theorem , Reproducibility of Results , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Treatment Outcome
19.
J Am Heart Assoc ; 11(22): e026904, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36326051

ABSTRACT

Background There are few US Food and Drug Administration (FDA)-approved devices specifically aimed at the pediatric patient with arrhythmia. This has led to a high off-label utilization of devices in this vulnerable population. The Pediatric and Congenital Electrophysiology Society (PACES), the international organization representing pediatric and congenital heart disease arrhythmia specialists, developed a task force to comprehensively address device development issues relevant to pediatric patients with congenital arrhythmia. Methods and Results As a first step, the taskforce developed a 26-question survey for the pediatric arrhythmia community to assess providers' understanding of the FDA approval process, specifically in regard to pediatric labeling. There were 92/211 respondents (44%) with a >90% completion rate. The vast majority of respondents believed there was a paucity of devices available for children (96%). More than 60% of respondents stated that they did not understand the FDA regulatory process and were not aware of whether the devices they used were labeled for pediatric use. Conclusions Pediatric electrophysiologists are keenly aware of the deficit of available pediatric devices for their patients. The majority do not understand the FDA approval process and could benefit from additional educational resources regarding this. A collaborative forum including PACES, FDA, patients and their families, and Industry would be an important next step in clarifying opportunities and priorities to serve this vulnerable population.


Subject(s)
Arrhythmias, Cardiac , Heart Defects, Congenital , Humans , Child , United States , United States Food and Drug Administration , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Surveys and Questionnaires , Electrophysiology
20.
J Am Heart Assoc ; 11(22): e025121, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36346046

ABSTRACT

Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18-77) years at initiation of CRT. Median follow-up time was 4.1 (25th-75th percentile, 1.3-8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro-transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th-75th percentile, II-III; after CRT: II, 25th-75th percentile, II-III; P=0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P=0.003) in patients with pre-CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long-term follow-up with a marginal but significant increase in SRV function (before CRT; 30%, 25th-75th percentile, 25-35; after CRT: 31%, 25th-75th percentile, 21-38; P=0.049). In contrast, no beneficial change in the above-mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow-up, and mortality at latest follow-up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing-induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Transposition of Great Vessels , Humans , Adult , Female , Middle Aged , Male , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Heart Ventricles , Retrospective Studies , Treatment Outcome , Heart Failure/diagnosis , Heart Failure/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...