Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Ophthalmol Case Rep ; 34: 101954, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38577387

ABSTRACT

Purpose: To report the clinical course of an aphakic patient who developed positional secondary angle closure glaucoma following pars plana vitrectomy (PPV) with perfluoropropane (C3F8) gas tamponade. Observations: A 23-year-old male presented due to a two-year history of vision loss in the left eye. Best-corrected visual acuity (BCVA) was 20/200 and intraocular pressure (IOP) was 12 mm Hg OS. Exam revealed iridodonesis and aphakia of both eyes, and a total RRD in the left eye. The patient underwent scleral buckle plus PPV with 15 % C3F8 gas and was instructed to maintain face-down positioning for 5 days. On post-operative day 1, IOP was 32 mm Hg and exam revealed significant diffuse corneal edema, a large epithelial defect, and 85 % C3F8 fill of the vitreous cavity. Patient was started on IOP-lowering drops but continued to have elevated IOP and corneal epithelial sloughing over the next 3 weeks. He was taken for a superficial keratectomy, but when placed supine under the microscope, a large new gas bubble was visualized overlying the pupil in a now shallow anterior chamber (AC) and IOP was 52 mm Hg. The patient was positioned back upright and the gas bubble migrated posteriorly out of the AC with return of IOP to 25 mm Hg. The dynamic nature of his IOP raised concerns for intermittent angle closure by C3F8 induced by supine positioning. Thus, a pars plana aspiration of the C3F8 gas was performed and resulted in normalization of the IOP. Conclusions and importance: Dynamic, positional secondary angle closure glaucoma can occur after vitrectomy with C3F8 in the setting of aphakia. This is the first report to capture C3F8 gas migration causing intermittent acute angle closure in real-time. Due to its intermittent nature however, the diagnosis may not be initially apparent at the slit lamp. Thus, we suggest this potential complication should be carefully monitored for and discussed when advising post-vitrectomy positioning in aphakic patients.

2.
Graefes Arch Clin Exp Ophthalmol ; 261(3): 779-789, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36271934

ABSTRACT

PURPOSE: To evaluate the safety and efficacy of Xen45 Gel stent (Xen; Allergan) in eyes that have failed prior surgical intervention, compared to traditional glaucoma drainage device (GDD) or continuous-wave cyclophotocoagulation (CPC). Since this population has low expected success rates with additional surgery, it is vital to compare to standard-of-care surgical options. METHODS: Retrospective, single-center, case-control study of ab externo transconjunctival Xen shunt in eyes that have previously undergone trabeculectomy and/or GDD surgery. Postoperative data were collected for 18 months. Failure was defined as no light perception, additional glaucoma surgery required, or intraocular pressure (IOP) of < 6 mmHg after 6 weeks postoperatively. RESULTS: Eighteen Xen eyes and 36 control eyes matched on both glaucoma type and previous glaucoma surgeries were included. Seventy-two percent had primary open angle glaucoma, 11% uveitic, 6% primary angle closure, 6% pseudoexfoliation, and 6% pigmentary glaucoma. Fifty-six percent of eyes in each group had prior trabeculectomy, 28% of Xen and 31% of control eyes had prior GDD, and 17% of Xen and 14% of control eyes had both. Baseline medicated IOP was lower in the Xen group (21.8 ± 7.2) compared to controls (27.5 ± 9.4, P = 0.043). The cumulative failure rate at year 1 was 17% for Xen and 20% for controls (P = 0.57). Mean survival time was 14.1 (± 1.5) months and 11.4 (± 0.6) months for controls. There was no difference in minor complication rates between groups (P = 0.65), but the Xen group had a significantly lower rate of serious complications (P = 0.043) defined as vision threatening or requiring surgical intervention in the operating room. When censored for additional glaucoma procedures, there were no differences at year 1 in IOP, change in IOP, number of IOP-lowering medications, or number of medications reduced from baseline. CONCLUSIONS: The Xen shunt provides a reasonable alternative to current standard of care, with a similar failure rate at year 1, with a noninferior IOP reduction compared to GDD and CPC, and a preferred safety profile.


Subject(s)
Glaucoma Drainage Implants , Glaucoma, Open-Angle , Glaucoma , Humans , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/surgery , Retrospective Studies , Case-Control Studies , Treatment Outcome , Glaucoma/diagnosis , Glaucoma/surgery , Intraocular Pressure , Stents
4.
Ophthalmic Surg Lasers Imaging ; 43(5): 425-30, 2012.
Article in English | MEDLINE | ID: mdl-22978523

ABSTRACT

BACKGROUND AND OBJECTIVE: The management of evisceration and enucleation has changed over time. The authors assessed the practice patterns regarding eye removal among oculoplastic surgeons. PATIENTS AND METHODS: Internet-based surveys were sent to American Society of Ophthalmic Plastic and Reconstructive Surgeons members regarding preferences in evisceration and/or enucleation, including indications, surgical techniques, preoperative evaluation modalities, implant types used, and postoperative complications experienced. RESULTS: Surgeons who recently completed fellowship training are more likely to perform eviscerations than their senior counterparts. The variety of viable implant types and the use of enucleation or evisceration for certain indications were not always in concordance with historical guiding principles. However, changing trends are in line with the current literature. CONCLUSION: Current practice patterns reflect recent literature and historical trends.


Subject(s)
Eye Enucleation/statistics & numerical data , Eye Evisceration/statistics & numerical data , Ophthalmology/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Eye Diseases/surgery , Health Care Surveys , Humans , Orbital Implants/statistics & numerical data , Surveys and Questionnaires , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...