Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 81
Filter
1.
Pediatr Cardiol ; 2024 Sep 21.
Article in English | MEDLINE | ID: mdl-39305323

ABSTRACT

To evaluate the association between initial management strategy of neonatal symptomatic Tetralogy of Fallot (sTOF) and later health-related quality of life (HRQOL) outcomes. We performed a multicenter, cross-sectional evaluation of a previously assembled cohort of infants with sTOF who underwent initial intervention at ≤ 30 days of age, between 2005 and 2017. Eligible patients' parents/guardians completed an age-appropriate Pediatric Quality of Life Inventory, a Pediatric Quality of Life Inventory Cardiac Module Heart Disease Symptoms Scale, and a parental survey. The association between treatment strategy and HRQOL was evaluated, and the entire sTOF cohort was compared to published values for the healthy pediatric population and to children with complex congenital heart disease and other chronic illness. The study cohort included 143 sTOF subjects, of which 59 underwent a primary repair, and 84 had a staged repair approach. There was no association between initial management strategy and lower HRQOL. For the entire cohort, in general, individual domain scores decreased as age sequentially increased. Across domain measurements, mean scores for the sTOF cohort were significantly lower than the healthy pediatric population and comparable to those with other forms of complex CHD and other chronic health conditions. The presence of a genetic syndrome was significantly associated with a poor HRQOL (p = 0.003). Initial treatment strategy for sTOF was not associated with differences in late HRQOL outcomes, though the overall HRQOL in this sTOF cohort was significantly lower than the general population, and comparable to others with chronic illness.

2.
JACC Adv ; 3(10): 101239, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39290814

ABSTRACT

Background: Neonates with tetralogy of Fallot and symptomatic cyanosis (sTOF) require early intervention, utilizing either a staged repair (SR) or primary repair (PR) approach. They are exposed to several sources of low-dose ionizing radiation, which may contribute to increased cancer risk. Objectives: The purpose of this study was to compare cumulative radiation exposure and associated lifetime attributable risk (LAR) of cancer between treatment strategies in sTOF. Methods: Neonates with sTOF who underwent SR or PR from 2012 to 2017 were retrospectively reviewed from the Congenital Cardiac Research Collaborative. Radiation exposure from all radiologic studies prior to 18 months of age was converted to organ-equivalent doses and projected LAR of cancer incidence using the National Cancer Institute dosimetry tools. Results: There were 242 neonates from 8 centers, including patients with 146 SR and 96 PR. Cumulative total effective dose was significantly higher for SR (median 8.3 mSv, IQR: 3.0-17.4 mSv) than PR (2.1 mSv, IQR: 0.8-8.5 mSv; P < 0.001). Cumulative organ-level doses were significantly higher in SR compared to PR. Regardless of treatment strategy, LARs were higher in females compared to males. Among organs with median exposure >1 mGy in females, the LAR was highest for breast in SR (mean 1.9/1,000 patients). The highest proportion of cancers attributable to radiation exposure was projected for thyroid cancer in females undergoing SR (7.3%). Conclusions: Cumulative radiation exposure and LARs were higher among those undergoing SR compared to PR. This will be an important factor to consider in determining the preferred neonatal treatment strategy and should substantiate efforts to reduce radiation exposure in this vulnerable population.

3.
Article in English | MEDLINE | ID: mdl-39087728

ABSTRACT

BACKGROUND: Transcatheter tricuspid valve-in-valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture. AIMS: Evaluate the feasibility of transcatheter tricuspid ViV replatement with fracture of the underlying BPV ring. METHODS: An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow-up data were collected. Comparison was made to the pre- and post-ViV replacement with fracture of the tricuspid valve frame conditions. RESULTS: Ten patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3-5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption. CONCLUSION: Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.

4.
Article in English | MEDLINE | ID: mdl-39033329

ABSTRACT

BACKGROUND: Patients with d-transposition of the great arteries (d-TGA) who have undergone an arterial switch operation (ASO) can develop right ventricular outflow tract (RVOT) dysfunction with pulmonary regurgitation (PR) or stenosis. In these patients, treatment may include transcatheter pulmonary valve replacement (TPVR). Coronary compression is a contraindication occurring in 5% of typical TPVR cases. After ASO, there are various anatomical considerations that can confound TPVR, including potential coronary artery compression. Our goal is to understand feasibility of TPVR in patients following ASO. METHODS: This was a retrospective multicenter cohort study of patients with RVOT dysfunction after ASO who underwent cardiac catheterization with intention to perform TPVR from 2008 to 2020. RESULTS: Across nine centers, 33 patients met inclusion criteria. TPVR was successful in 22 patients (66%), 19 receiving a Melody valve and 3 a SAPIEN valve. RVOT stenosis in isolation or with PR dictated need for TPVR in nearly all patients. One serious adverse event occurred with valve embolization. After TPVR, the RVOT peak gradient decreased from 43 to 9 mm Hg (p < 0.001); PR was trivial/none in all but one patient, in whom it was mild. Coronary compression prohibiting TPVR occurred in eight patients (24%) and two patients (6%) had severe aortic regurgitation from aortic root deformation precluding TPVR. Seven patients underwent RVOT reintervention with a median of 5.3 years post-TPVR. CONCLUSIONS: TPVR in patients with d-TGA after ASO is feasible, but in this cohort, coronary compression or aortic root distortion precluded TPVR in one-third of patients. The rate of RVOT reintervention after TPVR was higher in this cohort of ASO patients that in prior studies.

5.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839170

ABSTRACT

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Pulmonary Valve/surgery , Heart Defects, Congenital/surgery , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnosis , Ventricular Outflow Obstruction/surgery , Prosthesis Design , Bioprosthesis
6.
Pediatr Cardiol ; 2024 May 18.
Article in English | MEDLINE | ID: mdl-38761285

ABSTRACT

In the present era, the intricacy of procedures undertaken by a pediatric interventional cardiologist has increased, primarily attributed to dealing with smaller, younger patients with more complex anatomies. To adapt to these smaller and more complex patients, we must adapt our interventions and our equipment to perform these procedures. This article outlines various innovative applications of the SwiftNinja steerable microcatheter within the pediatric cardiac catheterization laboratory.

7.
Catheter Cardiovasc Interv ; 104(1): 61-70, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38736246

ABSTRACT

BACKGROUND: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need. METHODS: Multicenter, prospective, nonrandomized early feasibility study evaluating safety and effectiveness of the Minima stent for treatment of BPAS and CoAo. Primary endpoints included: (1) successful deployment across lesion, (2) stenosis relief defined by an increase in angiographic diameter of >50% and (3) freedom from stent explant, embolization or migration at 30 days and 6 months. RESULTS: Between 2/2022 and 5/2022, 10 pts underwent Minima stent implantation with a median age and weight of 9 months (4-43 months) and 7.6 kg (5.1-16.9 kg). Procedural success and predefined stenosis relief was achieved in all cases (CoAo [n = 4], BPAS [n = 6]). Adverse events occurred in 3 pts: transient diminished lower extremity pulse (n = 2), distal stent on-balloon displacement successfully managed in the catheterization suite (n = 1). There were no deaths or major adverse events. All patients were free from stent explant and migration at 30 days and 6 months with no evidence for significant restenosis at latest follow-up. CONCLUSIONS: Implantation of the Renata Minima stent was safe and effective for the treatment of BPAS and CoAo in this small cohort of infants and young children during early follow-up. Based on these early results, an expanded study with longer follow-up is warranted.


Subject(s)
Aortic Coarctation , Feasibility Studies , Prosthesis Design , Stenosis, Pulmonary Artery , Stents , Humans , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/therapy , Aortic Coarctation/physiopathology , Infant , Prospective Studies , Male , Female , Treatment Outcome , Stenosis, Pulmonary Artery/diagnostic imaging , Stenosis, Pulmonary Artery/physiopathology , Stenosis, Pulmonary Artery/therapy , Stenosis, Pulmonary Artery/etiology , Time Factors , Child, Preschool , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Age Factors , Angioplasty, Balloon/instrumentation , Angioplasty, Balloon/adverse effects
8.
J Pediatr ; 272: 114122, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38815742

ABSTRACT

OBJECTIVE: To test the hypothesis that neonates with symptomatic tetralogy of Fallot (TOF) and absent ductus arteriosus (ADA) have worse clinical outcomes compared with those with a ductus arteriosus (DA), and that this difference is driven by those born with ADA and with critically deficient pulmonary blood flow (CDPBF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of neonates who underwent intervention for symptomatic TOF comparing death and reintervention between subjects with and without a DA identified on fetal echocardiogram or on echocardiogram performed in the first postnatal day. Exclusion criteria were as follows: inability to define DA status, collaterals supplying pulmonary blood flow, atrioventricular septal defect, and absent pulmonary valve. We defined CDPBF as undergoing a procedure to augment pulmonary blood flow on the date of birth or extracorporeal membrane oxygenation prior to such a procedure. RESULTS: The study cohort included 519 patients, among whom 11% had ADA. Patients with ADA were more likely to have a genetic syndrome and had smaller branch pulmonary artery size. In analyses adjusting for center, interventional treatment strategy, genetic syndrome, and minimum branch pulmonary artery size, ADA was associated with higher mortality risk (adjusted hazard ratio of 2.37 (95% CI: 1.07,5.27; P = .034). Seven patients had CDPBF (1.3% of the entire cohort and 12% of patients with ADA). CONCLUSIONS: A minority of symptomatic TOF neonates have ADA, which is associated with higher adjusted mortality risk compared with those with a DA. CDPBF appears to be a rare but important entity in this population.


Subject(s)
Tetralogy of Fallot , Humans , Tetralogy of Fallot/mortality , Retrospective Studies , Infant, Newborn , Female , Male , Echocardiography , Cohort Studies , Ductus Arteriosus/diagnostic imaging , Treatment Outcome
9.
Cardiol Young ; : 1-3, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38618881

ABSTRACT

Immobilisation of mechanical valve leaflets can be a life-threatening complication. In the acute setting, medical therapy can be attempted but is not always successful. We present the first described case of a patient with a mechanical tricuspid valve with recurrent leaflet immobilisation that was able to be mobilised using a transcatheter knocking technique.

10.
Catheter Cardiovasc Interv ; 103(4): 580-586, 2024 03.
Article in English | MEDLINE | ID: mdl-38353500

ABSTRACT

BACKGROUND: Use of alternate access for complex neonatal interventions has gained acceptance with carotid and axillary artery access being used for ductal and aortic interventions. METHODS: This study was a retrospective, single-center study at Cincinnati Children's Hospital Medical Center. The study included infants, aged ≤90 days, who underwent cardiac catheterization with either carotid or axillary artery access between 2013 and 2022. Data encompassing demographics, clinical information, catheterization data, and the incidence of pseudoaneurysm as a procedural complication were collected. RESULTS: Among 29 young infants (20 males, 69%), 4 out of 15 patients (27%) who underwent the carotid approach developed pseudoaneurysms, while 1 out of 14 patients (7.1%) who underwent the axillary approach developed one. Two patients required transcatheter intervention due to enlargement of pseudoaneurysms, involving the placement of transarterial flow-diverting stent and occlusion of left common carotid artery. Longer sheath in-to-out time (135 vs. 77 min, p = 0.001), and higher closing activated clotting times (ACT) (268 vs. 197 s, p = 0.021) were observed among patients with pseudoaneurysms compared to those without. CONCLUSIONS: Young infants with alternative access via the carotid and axillary arteries may be at risk of pseudoaneurysm formation during longer procedures and with higher ACTs for closure. Ultrasound-guided compression can be employed to prevent the progression and in resolution of these lesions.


Subject(s)
Aneurysm, False , Male , Infant, Newborn , Infant , Child , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/epidemiology , Aneurysm, False/etiology , Axillary Artery/diagnostic imaging , Retrospective Studies , Incidence , Treatment Outcome , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Risk Factors , Femoral Artery
11.
Circ Cardiovasc Interv ; 17(3): e012834, 2024 03.
Article in English | MEDLINE | ID: mdl-38258562

ABSTRACT

BACKGROUND: Current metrics used to adjust for case mix complexity in congenital cardiac catheterization are becoming outdated due to the introduction of novel procedures, innovative technologies, and expanding patient subgroups. This study aims to develop a risk adjustment methodology introducing a novel, clinically meaningful adverse event outcome and incorporating a modern understanding of risk. METHODS: Data from diagnostic only and interventional cases with defined case types were collected for patients ≤18 years of age and ≥2.5 kg at all Congenital Cardiac Catheterization Project on Outcomes participating centers. The derivation data set consisted of cases performed from 2014 to 2017, and the validation data set consisted of cases performed from 2019 to 2020. Severity level 3 adverse events were stratified into 3 tiers by clinical impact (3a/b/c); the study outcome was clinically meaningful adverse events, severity level ≥3b (3bc/4/5). RESULTS: The derivation data set contained 15 224 cases, and the validation data set included 9462 cases. Clinically meaningful adverse event rates were 4.5% and 4.2% in the derivation and validation cohorts, respectively. The final risk adjustment model included age <30 days, Procedural Risk in Congenital Cardiac Catheterization risk category, and hemodynamic vulnerability score (C statistic, 0.70; Hosmer-Lemeshow P value, 0.83; Brier score, 0.042). CONCLUSIONS: CHARM II (Congenital Heart Disease Adjustment for Risk Method II) risk adjustment methodology allows for equitable comparison of clinically meaningful adverse events among institutions and operators with varying patient populations and case mix complexity performing pediatric cardiac catheterization.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Child , Humans , Infant , Risk Factors , Treatment Outcome , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Hemodynamics , Risk Adjustment/methods
12.
Catheter Cardiovasc Interv ; 102(6): 1105-1108, 2023 11.
Article in English | MEDLINE | ID: mdl-37855191

ABSTRACT

Intracardiac masses and specifically right atrial thrombi can be difficult to manage and carry a high mortality rate. Typically, surgical removal or mechanical thrombectomy can be performed though may not be suitable for all patients. We present a unique case of a sickle cell patient with a large pedunculated right atrial thrombus that was successfully extracted using the novel ONO Retrieval Device.


Subject(s)
Atrial Fibrillation , Heart Diseases , Thrombosis , Humans , Thrombectomy , Heart Diseases/diagnostic imaging , Heart Diseases/surgery , Treatment Outcome , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/surgery
13.
J Perinatol ; 43(10): 1238-1244, 2023 10.
Article in English | MEDLINE | ID: mdl-37587183

ABSTRACT

OBJECTIVE: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder. STUDY DESIGN: Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or procedure-related events were evaluated. A total of 156 of the available 182 patients (86%) completed the study. RESULTS: The implant success rate was 95.5% (191/200). At 3 years, PDA closure was observed in 100% (33/33) of patients. Survival was >95% with 9 reported deaths. No deaths were adjudicated as device- or procedure-related. Notable events included aortic obstruction (2) requiring stent placement and tricuspid regurgitation (5), for which no interventions were required. CONCLUSIONS: This follow-up study demonstrates high rates of PDA closure, low serious complication rates, and survival > 95% at 3 years. The Amplatzer Piccolo™ Occluder is a safe and effective therapy for PDA treatment in premature infants. CLINICALTRIALS: gov identifier: NCT0305585.


Subject(s)
Ductus Arteriosus, Patent , Septal Occluder Device , Infant , Humans , Child , Follow-Up Studies , Ductus Arteriosus, Patent/surgery , Prospective Studies , Cardiac Catheterization/adverse effects , Septal Occluder Device/adverse effects , Treatment Outcome
14.
J Am Coll Cardiol ; 82(7): 615-627, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37558375

ABSTRACT

BACKGROUND: Neonates with symptomatic tetralogy of Fallot (sTOF) with hypoplastic pulmonary arteries (hPA) are considered high risk. Data are needed to inform the impact of hPA on outcomes, and the ideal management strategy. OBJECTIVES: The objectives of this study were to quantify the impact of hPA on outcomes in neonates with sTOF and measure the impact of strategy on pulmonary artery (PA) growth in this population. METHODS: Neonates with sTOF from 2005 to 2017 were reviewed from the Congenital Cardiac Research Collaborative. Criteria for hPA included a unilateral PA z score <-2.0 and contralateral PA z score <0. Primary outcome was mortality. Secondary outcomes included reintervention and PA growth. RESULTS: We included 542 neonates with sTOF, including 188 (35%) with hPA and 354 (65%) with normal PA, with median follow-up of 4.1 years. Median right and left hPA z scores were -2.19 (25th-75th percentile: -2.55 to -1.94) and -2.23 (25th-75th percentile: -2.64 to -1.91), respectively. Staged repair (vs primary TOF repair) was less common in the hPA cohort (36 vs 44%; P = 0.07). Survival was similar between groups (unadjusted P = 0.16; adjusted P = 0.25). Reintervention was more common in the hPA group (HR: 1.28; 95% CI: 1.01-1.63; P = 0.044); there was no difference after definitive repair (HR: 1.21; 95% CI: 0.93-1.58; P = 0.16). PA growth at 1 year was greater in the hPA cohort, particularly for the right PA (P < 0.001). CONCLUSIONS: Despite perception, the presence of hPA in neonates with sTOF conferred no increase in overall hazard of mortality or reintervention after definitive repair. PA growth was superior in the hPA cohort. These findings suggest that the presence of hPA does not adversely impact outcomes in sTOF.


Subject(s)
Tetralogy of Fallot , Infant, Newborn , Humans , Infant , Tetralogy of Fallot/surgery , Pulmonary Artery/surgery , Treatment Outcome , Retrospective Studies
15.
Cardiol Young ; 33(11): 2405-2407, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37317799

ABSTRACT

Mechanical thrombectomy is generally used in adult patients with pulmonary embolism or extensive venous thromboembolism, but it is starting to become more prevalent in the children. We present a unique case of a 3-year-old female with very early-onset inflammatory bowel disease with extensive venous thromboembolism who underwent successful mechanical thrombectomy.


Subject(s)
Inflammatory Bowel Diseases , Pulmonary Embolism , Venous Thromboembolism , Venous Thrombosis , Adult , Female , Child , Humans , Child, Preschool , Thrombectomy , Venous Thrombosis/complications , Venous Thrombosis/surgery , Pulmonary Embolism/complications , Pulmonary Embolism/surgery , Inflammatory Bowel Diseases/complications
16.
Pediatr Cardiol ; 44(8): 1691-1701, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37382636

ABSTRACT

The Pediatric Heart Network's Fontan Udenafil Exercise Longitudinal (FUEL) Trial (Mezzion Pharma Co. Ltd., NCT02741115) demonstrated improvements in some measures of exercise capacity and in the myocardial performance index following 6 months of treatment with udenafil (87.5 mg twice daily). In this post hoc analysis, we evaluate whether subgroups within the population experienced a differential effect on exercise performance in response to treatment. The effect of udenafil on exercise was evaluated within subgroups defined by baseline characteristics, including peak oxygen consumption (VO2), serum brain-type natriuretic peptide level, weight, race, gender, and ventricular morphology. Differences among subgroups were evaluated using ANCOVA modeling with fixed factors for treatment arm and subgroup and the interaction between treatment arm and subgroup. Within-subgroup analyses demonstrated trends toward quantitative improvements in peak VO2, work rate at the ventilatory anaerobic threshold (VAT), VO2 at VAT, and ventilatory efficiency (VE/VCO2) for those randomized to udenafil compared to placebo in nearly all subgroups. There was no identified differential response to udenafil based on baseline peak VO2, baseline BNP level, weight, race and ethnicity, gender, or ventricular morphology, although participants in the lowest tertile of baseline peak VO2 trended toward larger improvements. The absence of a differential response across subgroups in response to treatment with udenafil suggests that the treatment benefit may not be restricted to specific sub-populations. Further work is warranted to confirm the potential benefit of udenafil and to evaluate the long-term tolerability and safety of treatment and to determine the impact of udenafil on the development of other morbidities related to the Fontan circulation.Trial Registration NCT0274115.


Subject(s)
Oxygen Consumption , Sulfonamides , Humans , Child , Sulfonamides/therapeutic use , Exercise , Pyrimidines/therapeutic use , Exercise Test , Exercise Tolerance
17.
Pediatr Cardiol ; 44(6): 1414-1417, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37227453

ABSTRACT

Management of pulmonary atresia, ventricular septal defect with major aorto-pulmonary collateral arteries, and hypoplastic native pulmonary arteries focuses on growth of the native pulmonary arteries. One strategy to grow the native pulmonary arteries is through pulmonary valve perforation followed by right ventricular outflow tract stenting, if suitable. We present a unique case of retrograde pulmonary valve perforation and stenting of the right ventricular outflow tract through a major aorto-pulmonary collateral artery.


Subject(s)
Heart Defects, Congenital , Heart Septal Defects, Ventricular , Pulmonary Atresia , Pulmonary Valve , Humans , Infant , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Pulmonary Atresia/diagnostic imaging , Pulmonary Atresia/surgery , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Pulmonary Artery/abnormalities , Collateral Circulation
18.
Pediatr Cardiol ; 44(5): 1183-1186, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36867232

ABSTRACT

Transcatheter tricuspid valve placement in congenital heart disease is becoming increasingly used when a previously placed surgical ringed valve becomes dysfunctional. Surgically repaired and/or native tricuspid inflows are generally not amenable to transcatheter valve placement without a prior ring being placed. We present the second pediatric case to our knowledge of transcatheter tricuspid valve placement in a surgically repaired tricuspid valve in the absence of a ring.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Child , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Treatment Outcome , Cardiac Catheterization , Prosthesis Design
19.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36995404

ABSTRACT

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Subject(s)
Ductus Arteriosus, Patent , Septal Occluder Device , Infant , Humans , Ductus Arteriosus, Patent/surgery , Treatment Outcome , Cardiac Catheterization/methods , Registries , Time Factors , Retrospective Studies
20.
World J Pediatr Congenit Heart Surg ; 14(4): 527-530, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36972508

ABSTRACT

Microvascular pulmonary arteriovenous malformations (pAVMs) can lead to profound hypoxemia. "Hepatic factor" is postulated to play a role in their development. Certain patients with congenital heart disease are at particular risk to develop pAVMs, including those with heterotaxy syndromes and complex Fontan palliation. Ideally, an underlying cause is identified and corrected, although pAVMs may persist despite those interventions. We report a patient with heterotaxy syndrome s/p Fontan who had pAVMs that persisted despite Fontan revision with equal hepatic flow to both lungs. We employed a novel method to produce a diabolo configuration of a large covered stent to restrict lung flow while maintaining the potential for future dilation.


Subject(s)
Arteriovenous Malformations , Heterotaxy Syndrome , Pulmonary Veins , Humans , Arteriovenous Malformations/complications , Arteriovenous Malformations/diagnostic imaging , Arteriovenous Malformations/surgery , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Pulmonary Artery/abnormalities , Pulmonary Veins/surgery , Pulmonary Veins/abnormalities , Heterotaxy Syndrome/complications , Heterotaxy Syndrome/surgery , Cyanosis/etiology , Cyanosis/surgery , Stents/adverse effects
SELECTION OF CITATIONS