1.
Med Phys ; 35(7): 3317-30, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18697556

ABSTRACT

Percentage depth dose (PDD) distributions and beam profiles of very small diameter (1.5-5 mm) megavoltage radiosurgical beams calculated with Monte Carlo (MC) technique critically depend on the diameter of the circular focal spot used in the simulation: The smaller is the field diameter, the larger is the effect. Thus, in simulations of radiosurgical fields that have diameters of the order of the focal spot size, an accurate focal spot geometry should be used. We used a simplified moving slit technique in conjunction with a diode detector for evaluation of the focal spot size and shape of a megavoltage 6 MV linac as well as for determination of the equivalent focal spot diameter of the linac for use in MC simulations. The measured total diode signal contains three components: A direct focal spot signal, a background signal, and an extra-focal radiation signal. A single profile scan of the focal spot signal is Gaussian like in shape, and its full width at half maximum is used to define the focal spot dimension for this scan. The focal spot of our 6 MV linac is approximated with a Gaussian circle, and when the geometry of the effective focal spot circle is used in MC simulations, the agreement between MC-calculated and measured PDD distributions as well as beam profiles is good even for radiosurgical fields as small as 1.5 mm in diameter. Our results also confirm that matching the penumbral areas of accurately measured large-field beam profiles to the same areas of the MC-calculated beam profiles reliably leads to a realistic effective focal spot size for use in MC simulations of very small diameter beams.


Subject(s)
Radiosurgery/instrumentation , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , X-Rays , Air , Computer Simulation , Equipment Design , Humans , Models, Statistical , Models, Theoretical , Monte Carlo Method , Normal Distribution , Particle Accelerators , Reproducibility of Results , Scattering, Radiation , Time Factors
2.
Med Phys ; 32(7): 2245-53, 2005 Jul.
Article in English | MEDLINE | ID: mdl-16121579

ABSTRACT

In this study, a measurement protocol is presented that improves the precision of dose measurements using a flat-bed document scanner in conjunction with two new GafChromic film models, HS and Prototype A EBT exposed to 6 MV photon beams. We established two sources of uncertainties in dose measurements, governed by measurement and calibration curve fit parameters contributions. We have quantitatively assessed the influence of different steps in the protocol on the overall dose measurement uncertainty. Applying the protocol described in this paper on the Agfa Arcus II flat-bed document scanner, the overall one-sigma dose measurement uncertainty for an uniform field amounts to 2% or less for doses above around 0.4 Gy in the case of the EBT (Prototype A), and for doses above 5 Gy in the case of the HS model GafChromic film using a region of interest 2 X 2 mm2 in size.


Subject(s)
Algorithms , Computer Peripherals , Film Dosimetry/instrumentation , Film Dosimetry/methods , Dose-Response Relationship, Radiation , Radiation Dosage
3.
Med Phys ; 32(7Part1): 2245-2253, 2005 Jul.
Article in English | MEDLINE | ID: mdl-28493574

ABSTRACT

In this study, a measurement protocol is presented that improves the precision of dose measurements using a flat-bed document scanner in conjunction with two new GafChromic® film models, HS and Prototype A EBT exposed to 6MV photon beams. We established two sources of uncertainties in dose measurements, governed by measurement and calibration curve fit parameters contributions. We have quantitatively assessed the influence of different steps in the protocol on the overall dose measurement uncertainty. Applying the protocol described in this paper on the Agfa Arcus II flat-bed document scanner, the overall one-sigma dose measurement uncertainty for an uniform field amounts to 2% or less for doses above around 0.4Gy in the case of the EBT (Prototype A), and for doses above 5Gy in the case of the HS model GafChromic® film using a region of interest 2×2mm2 in size.