Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3003-3006, 2022 07.
Article in English | MEDLINE | ID: mdl-36086423

ABSTRACT

This paper reports the application of a low-cost diagnostic modality for fat analysis in a liver phantom as well as human liver donors. The device works on the principle of diffuse reflectance spectroscopy, which absorbs and/or scatters depending upon the molecules that compose a tissue. Here, we describe the development of liver phantom of varying fat concentration using saturated fat mimicking liver steatosis. Followed by a pilot study in the human liver donor setting. Later, handheld device based on Infrared-LED and Photodetector for real-time time assessment of live donor liver and fat assessment. Clinical Relevance- This device can be used in the development of an accurate and non-invasive for quantification of liver fat in the deceased donor selection process. It has an error margin of 10% in the quantification of fat which is comparable to a standard biopsy technique.


Subject(s)
Fatty Liver , Liver Transplantation , Fatty Liver/diagnostic imaging , Humans , Living Donors , Pilot Projects , Spectrum Analysis
2.
IEEE Sens J ; 21(20): 22758-22766, 2021 Oct 15.
Article in English | MEDLINE | ID: mdl-35582121

ABSTRACT

SARS-CoV-2 nucleocapsid protein-based COVID-19 diagnosis is a promising alternative to the high-priced, time-consuming, and labor-intensive RT-PCR tests. Here, we developed a rapid, dip-type, wash-free plasmonic fiber optic absorbance biosensor (P-FAB) strategy for the point-of-care detection of SARS-CoV-2 N-protein, expressed abundantly during the infection. P-FAB involves a sandwich assay with plasmonic labels on the surface of a U-bent fiber optic sensor probe with a high evanescent wave absorbance (EWA) sensitivity. The SARS-CoV-2 N-protein is quantified in terms of the change in the intensity of the light propagating through the U-bent sensor probe coupled to a green LED and a photodetector. Firstly, the optical fiber material (silica vs. polymeric optical fiber), was evaluated to realize a sensitive sensor platform. The optimal size of AuNP labels (20, 40, and 60 nm) to achieve high sensitivity and a lower limit of detection (LoD) was investigated. Following the P-FAB strategy, fused silica/glass optical fiber (GOF) U-bent senor probe and citrate-capped AuNP labels (size ~40 nm) gave rise to an LoD down to ~2.5 ng/mL within 10 mins of read-out time. Further, studies on development and validation of a point of care (PoC) read-out device, and preclinical studies are in progress.

SELECTION OF CITATIONS
SEARCH DETAIL
...