Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
Vet Radiol Ultrasound ; 54(6): 591-604, 2013.
Article in English | MEDLINE | ID: mdl-23919809

ABSTRACT

Contrast-enhanced multi-detector computed tomography (CE-MDCT) is used routinely in evaluating human patients with acute abdominal symptoms. Contrast-enhanced ultrasound (CEUS) continues to be in its infancy as it relates to evaluation of the acute abdomen. The purpose of this study was to compare survey radiography, B-mode ultrasound, CEUS, and CE-MDCT findings in canine patients presenting with acute abdominal signs; with a focus on the ability to differentiate surgical from non-surgical conditions. Nineteen dogs were prospectively enrolled. Inclusion required a clinical diagnosis of acute abdominal signs and confirmed surgical or non-surgical causes for the clinical signs. Agreement for the majority of recorded imaging features was at least moderate. There was poor agreement in the identification of pneumoperitoneum and in the comparison of pancreatic lesion dimensions for B-mode vs. CEUS. The CT feature of fat stranding was detected in cases including, but not limited to, gastric neoplasia with perforation, pancreatitis, and small intestinal foreign body. Ultrasound underestimated the size and number of specific lesions when compared with CE-MDCT. Contrast-enhanced ultrasound was successful in detecting bowel and pancreatic perfusion deficits that CE-MDCT failed to identify. Accuracy for differentiation of surgical vs. non-surgical conditions was high for all modalities; 100%, 94%, and 94% for CE-MDCT, ultrasonography and survey radiography respectively. Findings indicated that CE-MDCT is an accurate screening test for differentiating surgical from non-surgical acute abdominal conditions in dogs. Focused CEUS following CE-MDCT or B-mode ultrasonography may be beneficial for identifying potentially significant hypoperfused lesions.


Subject(s)
Abdomen, Acute/veterinary , Dog Diseases/diagnostic imaging , Multidetector Computed Tomography/veterinary , Ultrasonography/veterinary , Abdomen/diagnostic imaging , Abdomen, Acute/diagnostic imaging , Abdomen, Acute/pathology , Animals , Dog Diseases/pathology , Dogs , Female , Male , Prospective Studies , Radiography, Abdominal/veterinary , Sensitivity and Specificity
3.
J Am Vet Med Assoc ; 242(9): 1255-9, 2013 May 01.
Article in English | MEDLINE | ID: mdl-23600783

ABSTRACT

OBJECTIVE: To determine the incidence of adverse events within 24 hours after contrast-enhanced ultrasonography (CEUS) in dogs and cats and compare the risk of death within 24 hours after imaging for animals that underwent ultrasonography with and without injection of a contrast agent. DESIGN: Retrospective case-control study. ANIMALS: 750 animals (411 case dogs, 238 control dogs, 77 case cats, and 24 control cats). PROCEDURES: At 11 institutions, medical records were reviewed of dogs and cats that had CEUS performed (cases) as were medical records of dogs and cats with clinical signs similar to those of case animals that had ultrasonography performed without injection of a contrast agent (controls). Information regarding signalment; preexisting disease; type, dose, and administration route of contrast agent used; immediate (within 1 hour after CEUS) and delayed (> 1 and ≤ 24 hours after CEUS) adverse events; and occurrence and cause of death (when available) was extracted from each medical record. Risk of death within 24 hours after ultrasonography was compared between case and control animals. RESULTS: Of the 411 case dogs, 3 had immediate adverse events (vomiting or syncope) and 1 had a delayed adverse event (vomiting). No adverse events were recorded for case cats. Twenty-three of 357 (6.4%) clinically ill case animals and 14 of 262 (5.3%) clinically ill control animals died within 24 hours after ultrasonography; risk of death did not differ between cases and controls. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that CEUS was safe in dogs and cats.


Subject(s)
Cat Diseases/chemically induced , Contrast Media/adverse effects , Contrast Media/pharmacology , Dog Diseases/chemically induced , Ultrasonography/veterinary , Animals , Case-Control Studies , Cats , Dogs , Retrospective Studies , Ultrasonography/adverse effects , Ultrasonography/methods
4.
Vet Radiol Ultrasound ; 53(6): 605-12, 2012.
Article in English | MEDLINE | ID: mdl-22995037

ABSTRACT

Canine patients with acute abdominal signs are often clinically unstable and need a rapid and accurate diagnosis. Contrast-enhanced multi-detector computed tomography (CT) is the current modality of choice for evaluating acute abdominal pain in people. We hypothesized that contrast-enhanced multi-detector CT would be a feasible and safe technique for use in awake and lightly sedated dogs with acute abdominal signs. Eighteen client-owned dogs were enrolled, all presenting with acute abdominal signs. Dogs were scanned using a dual-phase protocol that included precontrast, arterial, and portal venous phases. Eight dogs were scanned awake and ten were given light sedation as chosen by the primary care clinician. Two observers who were unaware of clinical findings and sedation status scored image quality for each scan by consensus opinion. Mean serum creatinine in the sedated group was higher than in the awake group but was within the normal reference range. Other laboratory and physiologic measures did not differ between awake and sedated groups. No IV contrast-related adverse reactions were seen. Median scan time for all patients was less than 10 min. Sixteen of 18 contrast-enhanced multi-detector CT scans were scored fair to excellent in diagnostic quality, with no statistical difference in diagnostic quality for awake vs. sedated patients. Causes for two poor quality diagnostic scans included severe beam hardening from previously administered barium contrast agent and severe motion artifacts. We conclude that dual-phase contrast-enhanced multi-detector CT is a feasible and safe technique for evaluating awake and minimally sedated dogs presenting with acute abdominal signs.


Subject(s)
Abdomen, Acute/veterinary , Contrast Media , Dog Diseases/diagnostic imaging , Multidetector Computed Tomography/veterinary , Animals , Conscious Sedation , Contrast Media/administration & dosage , Dogs , Injections, Intravenous/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL
...