Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
World J Cardiol ; 1(1): 46-50, 2009 Dec 31.
Article in English | MEDLINE | ID: mdl-21160576

ABSTRACT

AIM: To find out whether serum oxidizability potential correlates with exercise test (EXT) parameters and predicts their results in chronic ischemic heart disease (IHD) patients. METHODS: Oxidizability potential was determined in a group of chronic IHD patients who underwent a symptom limited EXT upon initiation of a cardiac rehabilitation program. The thermo-chemiluminescence (TCL) assay was used to assess serum oxidizability potential. This assay is based on heat-induced oxidation of serum, leading to the formation of electronically excited species in the form of unstable carbonyls, which further decompose into stable carbonyls and light energy (low chemiluminescence). Measured photons emission is represented by a kinetic curve which is described by its amplitude and slope (= ratio). We assessed the correlations of TCL ratio with exercise duration, metabolic equivalents (METS), maximal heart rate (mHR), maximal systolic BP, > 1 mm S-T depression, diabetes, hypertension, smoking, left ventricular ejection fraction (LVEF) > or < 40%, previous myocardial infarction, and aorto-coronary by-pass surgery and compared to the TCL ratio measured in a group of healthy controls. RESULTS: A high TCL ratio (%) correlated well with METS (r = 0.84), with mHR (r = 0.79) and with exercise induced S-T segment shift (r = 0.87, P < 0.05). A lower serum oxidizability potential, expressed as a low TCL ratio, thus suggestive of a previous high oxidative stress, was found in IHD patients compared to healthy controls, and, in particular, in patients with low LVEF%. The TCL ratio (%) in IHD patients was 193 ± 21, compared to 215 ± 13 in controls (P < 0.05), and was 188 ± 14.7 in patients with LVEF < 40% as compared to 200 ± 11.9 in those with LVEF > 40% (P < 0.01). A trend for lower TCL ratio (%) was found in diabetic, hypertensive, and post-coronary bypass surgery patients. A paradoxically low TCL ratio (low oxidizability potential) was observed in patients without S-T depression compared to patients with S-T depression (189 ± 22 vs 201 ± 15, P = NS), due to the fact these patients had a much lower LVEF% and a lower exercise capacity. CONCLUSION: Serum oxidizability potential is associated with EXT parameters, results, and IHD severity. TCL ratio is an "easy-to-measure marker" that might be incorporated into risk assessment and prediction in chronic IHD patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...