1.
J Digit Imaging ; 24(3): 478-84, 2011 Jun.
Article in English | MEDLINE | ID: mdl-20386949

ABSTRACT

This study investigated the relative efficiencies of a stereographic display and two monoscopic display schemes for detecting lung nodules in chest computed tomography (CT). The ultimate goal was to determine whether stereoscopic display provides advantages for visualization and interpretation of three-dimensional (3D) medical image datasets. A retrospective study that compared lung nodule detection performances achieved using three different schemes for displaying 3D CT data was conducted. The display modes included slice-by-slice, orthogonal maximum intensity projection (MIP), and stereoscopic display. One hundred lung-cancer screening CT examinations containing 647 nodules were interpreted by eight radiologists, in each of the display modes. Reading times and displayed slab thickness versus time were recorded, as well as the probability, location, and size for each detected nodule. Nodule detection performance was analyzed using the receiver operating characteristic method. The stereo display mode provided higher detection performance with a shorter interpretation time, as compared to the other display modes tested in the study, although the difference was not statistically significant. The analysis also showed that there was no difference in the patterns of displayed slab thickness versus time between the stereo and MIP display modes. Most radiologists preferred reading the 3D data at a slab thickness that corresponded to five CT slices. Our results indicate that stereo display has the potential to improve radiologists' performance for detecting lung nodules in CT datasets. The experience gained in conducting the study also strongly suggests that further benefits can be achieved through providing readers with additional functionality.


Subject(s)
Lung Neoplasms/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Humans , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Lung/diagnostic imaging , Observer Variation , ROC Curve , Radiographic Image Enhancement/methods , Retrospective Studies
2.
Acta Radiol ; 51(8): 832-41, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20812886

ABSTRACT

Neoplastic and nonneoplastic diseases may involve the liver with a regional distribution, which is defined as a non-focal process without any specific anatomic predilection. In this pictorial essay we review hepatic diseases commonly presenting with a regional distribution in the liver and describe the CT and MR imaging findings helpful for differential diagnosis. Knowledge of the characteristic imaging manifestations of neoplastic and non-neoplastic diseases affecting the liver regionally will facilitate an accurate diagnosis and result in the appropriate clinical management of these liver diseases.


Subject(s)
Liver Diseases/diagnosis , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Diagnosis, Differential , Female , Humans , Liver Diseases/diagnostic imaging , Liver Neoplasms/diagnosis , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Male , Middle Aged , Sensitivity and Specificity
3.
AJR Am J Roentgenol ; 191(5): 1589-94, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18941106

ABSTRACT

OBJECTIVE: The purpose of our study was to retrospectively evaluate the effect of body weight and iodine dose on aortic and hepatic contrast enhancement in pediatric patients who underwent 64-MDCT of the abdomen and pelvis. MATERIALS AND METHODS: Eighty-seven consecutive pediatric patients (50 boys and 37 girls; median age, 12.1 years; age range, 3.8-17.6 years) underwent standard abdominopelvic CT with a 64-MDCT scanner. Contrast medium (350 mg I/mL) was injected using a power injector at 2 mL/s followed by 15-20 mL of saline flush. According to our CT protocol, the volume of administered contrast medium was approximately 1.8 mL/kg of body weight, up to the maximum volume of 80 mL. CT scanning was initiated 60 seconds after the start of the contrast medium injection. CT attenuations of the aorta and liver were measured. For each patient, the injected contrast medium iodine mass per body weight index (g I/kg) (hereafter, iodine mass body index) was calculated. Linear regression analysis was performed between iodine mass body index and aortic and hepatic attenuations. RESULTS: A wide range of patient weights (19-82 kg; mean, 48.6 kg [95% CI, 45.3-51.9 kg]) and contrast volumes (30-80 mL; median, 80.0 mL) were observed. The median attenuations were 149.0 HU (141.0-160.0 HU) for the aorta and 113.5 HU (109.5-120.0 HU) for the liver. Moderately high correlations were observed between iodine mass body index and aortic (Spearman's rho [r(s)] = 0.60 [0.45-0.72]; p < 0.001) and hepatic (r(s) = 0.60 [0.42-0.70]; p < 0.001) attenuations. The regression formulae for aortic attenuation (58.4 + 176.3 x iodine mass body index [p < 0.001]) and hepatic attenuation (58.7 + 108.5 x iodine mass body index [p < 0.001]) indicate that 1.5 and 1.8 mL/kg (350 mg I/mL) of contrast media are required to achieve 116 and 127 HU, respectively, of contrast-enhanced attenuation in the liver. CONCLUSION: In our study, using abdominal 64-MDCT in pediatric patients, we found that approximately 1.5 mL/kg, or 0.525 g I/kg, yields 116 HU of hepatic attenuation or 50-55 HU of hepatic enhancement.


Subject(s)
Aortography/methods , Body Weight , Liver/diagnostic imaging , Radiographic Image Enhancement/methods , Radiography, Abdominal/methods , Tomography, X-Ray Computed/methods , Triiodobenzoic Acids/administration & dosage , Adolescent , Child , Child, Preschool , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Female , Humans , Injections, Intravenous , Male , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
4.
J Digit Imaging ; 21 Suppl 1: S39-49, 2008 Oct.
Article in English | MEDLINE | ID: mdl-17874330

ABSTRACT

The goal of this study was to assess whether radiologists' search paths for lung nodule detection in chest computed tomography (CT) between different rendering and display schemes have reliable properties that can be exploited as an indicator of ergonomic efficiency for the purpose of comparing different display paradigms. Eight radiologists retrospectively viewed 30 lung cancer screening CT exams, containing a total of 91 nodules, in each of three display modes [i.e., slice-by-slice, orthogonal maximum intensity projection (MIP) and stereoscopic] for the purpose of detecting and classifying lung nodules. Radiologists' search patterns in the axial direction were recorded and analyzed along with the location, size, and shape for each detected feature, and the likelihood that the feature is an actual nodule. Nodule detection performance was analyzed by employing free-response receiver operating characteristic methods. Search paths were clearly different between slice-by-slice displays and volumetric displays but, aside from training and novelty effects, not between MIP and stereographic displays. Novelty and training effects were associated with the stereographic display mode, as evidenced by differences between the beginning and end of the study. The stereo display provided higher detection and classification performance with less interpretation time compared to other display modes tested in the study; however, the differences were not statistically significant. Our preliminary results indicate a potential role for the use of radiologists' search paths in evaluating the relative ergonomic efficiencies of different display paradigms, but systematic training and practice is necessary to eliminate training curve and novelty effects before search strategies can be meaningfully compared.


Subject(s)
Imaging, Three-Dimensional/methods , Lung Neoplasms/diagnostic imaging , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Solitary Pulmonary Nodule/diagnostic imaging , Tomography, X-Ray Computed/methods , Humans , Lung Neoplasms/pathology , Pilot Projects , Radiographic Image Enhancement/instrumentation , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Radiography/standards , Radiography/trends , Reproducibility of Results , Sensitivity and Specificity , Solitary Pulmonary Nodule/pathology , Statistics as Topic , Tomography, X-Ray Computed/instrumentation , X-Ray Intensifying Screens
SELECTION OF CITATIONS