Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Bioallied Sci ; 8(Suppl 1): S154-S159, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27829769

ABSTRACT

BACKGROUND: Chairside softliners are used more frequently than is reported and studies regarding the bond strength of chairside softliners to heat-polymerized denture base resin are few and limited. Hence, this study was conducted to comparatively evaluate the shear bond strength of two chairside soft relining materials viz., autopolymerizing plasticized acrylic resin liner and a silicone-based liner bonded to heat polymerized polymethyl methacrylate denture base resin and to analyze the mode of interfacial bond failure. MATERIALS AND METHODS: Forty test specimens (n = 40) were prepared by bonding plasticized acrylic- and silicone-based soft liner to heat polymerized acrylic resin blocks. Twenty specimens, ten from each group, were subjected to thermal cycling and later to shear bond strength testing. The debonded specimens were then qualitatively analyzed for the mode of failure using scanning electron microscopy. The results obtained were tabulated and statistically analyzed. RESULTS: The mean shear bond strength values obtained for acrylic-based soft liner before and after thermal cycling were 0.3365 ± 0.025 MPa and 0.3164 ± 0.04 MPa, respectively. The mean shear bond strength values obtained for silicone-based soft liner before and after thermal cycling were 0.4159 ± 0.025 MPa and 0.4335 ± 0.02 MPa, respectively. Silicone-based soft liner showed higher shear bond strength than the acrylic-based both before and after thermal cycling (P = 0.0001). Scanning electron microscopy analysis showed a predominantly mixed mode of failure with silicone-based liner and predominantly adhesive mode of failure with acrylic-based soft liner. CONCLUSION: The silicone-based soft liner showed higher shear bond strength to heat polymerized acrylic resin than acrylic-based soft liner both before and after thermal cycling.

2.
Int J Oral Maxillofac Implants ; 25(1): 38-44, 2010.
Article in English | MEDLINE | ID: mdl-20209185

ABSTRACT

PURPOSE: The aim of the present study was to compare the accuracy of casts obtained from nonsplinted and splinted direct impression techniques employing various splinting materials for multiple dental implants. MATERIALS AND METHODS: A reference model with four Nobel Replace Select implant replicas in the anterior mandible was fabricated with denture base heat-curing acrylic resin. Impressions of the reference model were made using polyether impression material by direct nonsplinted and splinted techniques. Impressions were divided into four groups: group A: nonsplinted technique; group B: acrylic resin-splinted technique; group C: bite registration addition silicone-splinted technique; and group D: bite registration polyether-splinted technique. Four impressions were made for each group and casts were poured in type IV dental stone. Linear differences in interimplant distances in the x-, y-, and z-axes and differences in interimplant angulations in the z-axis were measured on the casts using a coordinate measuring machine. RESULTS: The interimplant distance D1y showed significant variations in all four test groups (P = .043), while D3x values varied significantly between the acrylic resin-splinted and silicone-splinted groups. Casts obtained from the polyether-splinted group were the closest to the reference model in the x- and y-axes. In the z-axis, D2z values varied significantly among the three test groups (P = .009). Casts from the acrylic resin-splinted group were the closest to the reference model in the z-axis. Also, one of the three angles measured (angle 2) showed significant differences within three test groups (P = .009). Casts from the nonsplinted group exhibited the smallest angular differences. CONCLUSION: Casts obtained from all four impression techniques exhibited differences from the reference model. Casts obtained using the bite registration polyether-splinted technique were the most accurate versus the reference model, followed by those obtained via the acrylic resin-splinted, nonsplinted, and bite registration addition silicone-splinted techniques.


Subject(s)
Dental Implantation, Endosseous , Dental Impression Materials , Dental Impression Technique , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Jaw Relation Record , Acrylic Resins , Analysis of Variance , Humans , Models, Dental , Polyvinyls , Siloxanes , Splints
SELECTION OF CITATIONS
SEARCH DETAIL
...