Brain Stimul ; 17(3): 636-647, 2024.
Article in English | MEDLINE | ID: mdl-38734066

ABSTRACT

BACKGROUND: Transcranial ultrasound stimulation (TUS) is a non-invasive brain stimulation technique; when skull aberrations are compensated for, this technique allows, with millimetric accuracy, circumvention of the invasive surgical procedure associated with deep brain stimulation (DBS) and the limited spatial specificity of transcranial magnetic stimulation. OBJECTIVE: /hypothesis: We hypothesize that MR-guided low-power TUS can induce a sustained decrease of tremor power in patients suffering from medically refractive essential tremor. METHODS: The dominant hand only was targeted, and two anatomical sites were sonicated in this exploratory study: the ventral intermediate nucleus of the thalamus (VIM) and the dentato-rubro-thalamic tract (DRT). Patients (N = 9) were equipped with MR-compatible accelerometers attached to their hands to monitor their tremor in real-time during TUS. RESULTS: VIM neurostimulations followed by a low-duty cycle (5 %) DRT stimulation induced a substantial decrease in the tremor power in four patients, with a minimum of 89.9 % reduction when compared with the baseline power a few minutes after the DRT stimulation. The only patient stimulated in the VIM only and with a low duty cycle (5 %) also experienced a sustained reduction of the tremor (up to 93.4 %). Four patients (N = 4) did not respond. The temperature at target was 37.2 ± 1.4 °C compared to 36.8 ± 1.4 °C for a 3 cm away control point. CONCLUSIONS: MR-guided low power TUS can induce a substantial and sustained decrease of tremor power. Follow-up studies need to be conducted to reproduce the effect and better to understand the variability of the response amongst patients. MR thermometry during neurostimulations showed no significant thermal rise, supporting a mechanical effect.


Subject(s)
Essential Tremor , Humans , Essential Tremor/therapy , Essential Tremor/physiopathology , Male , Female , Middle Aged , Aged , Ventral Thalamic Nuclei/physiology , Treatment Outcome , Magnetic Resonance Imaging , Deep Brain Stimulation/methods , Deep Brain Stimulation/instrumentation
2.
Front Neuroimaging ; 2: 1272061, 2023.
Article in English | MEDLINE | ID: mdl-37953746

ABSTRACT

Introduction: Transcranial focused ultrasound therapy (tcFUS) offers precise thermal ablation for treating Parkinson's disease and essential tremor. However, the manual fine-tuning of fiber tracking and segmentation required for accurate treatment planning is time-consuming and demands expert knowledge of complex neuroimaging tools. This raises the question of whether a fully automated pipeline is feasible or if manual intervention remains necessary. Methods: We investigate the dependence on fiber tractography algorithms, segmentation approaches, and degrees of automation, specifically for essential tremor therapy planning. For that purpose, we compare an automatic pipeline with a manual approach that requires the manual definition of the target point and is based on FMRIB software library (FSL) and other open-source tools. Results: Our findings demonstrate the high feasibility of automatic fiber tracking and the automated determination of standard treatment coordinates. Employing an automatic fiber tracking approach and deep learning (DL)-supported standard coordinate calculation, we achieve anatomically meaningful results comparable to a manually performed FSL-based pipeline. Individual cases may still exhibit variations, often stemming from differences in region of interest (ROI) segmentation. Notably, the DL-based approach outperforms registration-based methods in producing accurate segmentations. Precise ROI segmentation proves crucial, surpassing the importance of fine-tuning parameters or selecting algorithms. Correct thalamus and red nucleus segmentation play vital roles in ensuring accurate pathway computation. Conclusion: This study highlights the potential for automation in fiber tracking algorithms for tcFUS therapy, but acknowledges the ongoing need for expert verification and integration of anatomical expertise in treatment planning.

3.
Ultrasound Med Biol ; 47(8): 2296-2309, 2021 08.
Article in English | MEDLINE | ID: mdl-33985825

ABSTRACT

High-intensity focused ultrasound (HIFU) is a non-invasive tool that can be used for targeted thermal ablation treatments. Currently, HIFU is clinically approved for treatment of uterine fibroids, various cancers, and certain brain applications. However, for brain applications such as essential tremors, HIFU can only be used to treat limited areas confined to the center of the brain because of geometrical limitations (shape of the transducer and skull). A major obstacle to advancing this technology is the inability to treat non-central brain locations without causing damage to the skin and/or skull. Previous research has indicated that cavitation-induced bubbles or microbubble contrast agents can be used to enhance HIFU treatments by increasing ablation regions and shortening acoustic exposures at lower acoustic pressures. However, little research has been done to explore the interplay between microbubble concentration and pressure amplitude on HIFU treatments. We developed an in vitro experimental setup to study lesion formation at three different acoustic pressures and three microbubble concentrations. Real-time ultrasound imaging was integrated to monitor initial microbubble concentration and subsequent behavior during the HIFU treatments. Depending on the pressure used for the HIFU treatment, there was an optimal concentration of microbubbles that led to enhanced heating in the focal area. If the concentration of microbubbles was too high, the treatment was detrimentally affected because of non-linear attenuation by the pre-focal microbubbles. Additionally, the real-time ultrasound imaging provided a reliable method to monitor microbubble activity during the HIFU treatments, which is important for translation to in vivo HIFU applications with microbubbles.


Subject(s)
Heating , High-Intensity Focused Ultrasound Ablation/methods , Microbubbles , Pressure , Phantoms, Imaging
4.
Article in English | MEDLINE | ID: mdl-33651688

ABSTRACT

Only one high-intensity focused ultrasound device has been clinically approved for transcranial brain surgery at the time of writing. The device operates within 650 and 720 kHz and corrects the phase distortions induced by the skull of each patient using a multielement phased array. Phase correction is estimated adaptively using a proprietary algorithm based on computed-tomography (CT) images of the patient's skull. In this article, we assess the performance of the phase correction computed by the clinical device and compare it to: 1) the correction obtained with a previously validated full-wave simulation algorithm using an open-source pseudo-spectral toolbox and 2) a hydrophone-based correction performed invasively to measure the aberrations induced by the skull at 650 kHz. For the full-wave simulation, three different mappings between CT Hounsfield units and the longitudinal speed of sound inside the skull were tested. All methods are compared with the exact same setup due to transfer matrices acquired with the clinical system for N = 5 skulls and T = 2 different targets for each skull. We show that the clinical ray-tracing software and the full-wave simulation restore, respectively, 84% ± 5% and 86% ± 5% of the pressure obtained with hydrophone-based correction for targets located in central brain regions. On the second target (off-center), we also report that the performance of both algorithms degrades when the average incident angles of the acoustic beam at the skull surface increase. When incident angles are higher than 20°, the restored pressure drops below 75% of the pressure restored with hydrophone-based correction.


Subject(s)
Brain , Skull , Brain/diagnostic imaging , Computer Simulation , Humans , Skull/diagnostic imaging , Tomography, X-Ray Computed , Ultrasonography
5.
Ultrasound Med Biol ; 45(2): 526-538, 2019 02.
Article in English | MEDLINE | ID: mdl-30522817

ABSTRACT

Sonodynamic therapy (SDT) is used to treat various malignancies and can be applied to brain tumors using a transcranial magnetic resonance imaging-guided focused ultrasound (TcMRgFUS) device. This study investigated the efficacy of 220-kHz TcMRgFUS combined with 5-aminolevulinic acid (5-ALA) on malignant glioma in vitro and in vivo. F98 cells were irradiated with focused ultrasound (FUS) (4000 J, 20 W, 240 s, 100% duty cycle, target medium temperature <40°C) after treatment with 200 µg/mL 5-ALA, and cell viability and apoptosis were evaluated with the water-soluble tetrazolium-1 assay, triple fluorescent staining and Western blot analysis 20 h later. The anti-tumor effects of 5-ALA combined with FUS (500 J, 18 W, 30 s, 100% duty cycle, 10 repeats, target tissue temperature ≤42°C) were assessed on the basis of changes in tumor volume determined by MRI and histopathological analysis before and after treatment. The FUS/5-ALA combination reduced cell viability by inducing apoptosis and suppressed tumor proliferation and invasion as well as angiogenesis in vivo, while causing minimal damage to normal brain tissue. SDT with 220-kHz TcMRgFUS and 5-ALA can be safely used for the treatment of malignant glioma.


Subject(s)
Brain Neoplasms/therapy , Glioma/therapy , Levulinic Acids/therapeutic use , Magnetic Resonance Imaging/methods , Radiology, Interventional/methods , Ultrasonic Therapy/methods , Animals , Brain/diagnostic imaging , Cell Line, Tumor , Cells, Cultured , Combined Modality Therapy/methods , Disease Models, Animal , Female , Rats , Rats, Inbred F344 , Aminolevulinic Acid