Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Minerva Cardiol Angiol ; 71(1): 51-60, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35212507

ABSTRACT

BACKGROUND: Provisional stenting is preferred for bifurcation lesion; however, certain anatomical substrate does require two stents as a part of dedicated stent technique. Here, the present study evaluated outcomes of ultra-thin (60 µm) Supra family sirolimus-eluting stent (SES) (Sahajanand Medical Technologies Limited, Surat, India) for dedicated bifurcation lesions using nano-crush technique at 12 months angiographic follow-up. METHODS: This was prospective, single-center observational study which enrolled patients with de novo bifurcation lesion and underwent angioplasty with Supra family SES using nano-crush technique at a tertiary care center in India, between March-2017 and February-2019. Primary endpoint at 12 months was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (CD-TLR). Secondary endpoints included patient-oriented composite endpoint (POCE), all-cause death, any revascularization, clinically driven target vessel revascularization, stent thrombosis, periprocedural and spontaneous MI, and device failure. RESULTS: The study enrolled total 63 patients with a mean age of 62.5±4.9 years and had male dominance (89%). Left main (LM) bifurcation and non-LM bifurcation were observed in 21 (33%) and 42 (67%) patients, respectively. Total 50 (80%) patients had Medina class- 1,1,1. At 12 months, TLF occurred in 4 (6%) patients which included one cardiac death (1.5%), two (3.0%) TV-MI, and one CD-TLR (1.5%). POCE was observed in 6 (9.6%) patients. Stent failure was seen in 2 (3.1%) patient and one patient (1.5%) developed late stent thrombosis. Twelve months angiographic follow-up indicated intact stent patency in all other patients. On multivariate analysis, LM bifurcation, renal dysfunction, LM bifurcation with renal dysfunction, ejection fraction (<35%) and calcified lesion were found as predictors of TLF. CONCLUSIONS: Dedicated stenting with ultra-thin Supra family SES for complex bifurcation lesion using nano-crush technique reported acceptable clinical outcomes among real-world patients and can be performed safely with ease without any procedural complications.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Kidney Diseases , Myocardial Infarction , Percutaneous Coronary Intervention , Thrombosis , Humans , Male , Middle Aged , Aged , Sirolimus/therapeutic use , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Prospective Studies , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Stents , Death
2.
Am J Cardiovasc Dis ; 11(5): 544-554, 2021.
Article in English | MEDLINE | ID: mdl-34849286

ABSTRACT

BACKGROUND: Coronary no-reflow (NRF) following percutaneous coronary intervention (PCI) is infrequent but one of the most dreaded complication which results from impaired flow of microvascular bed. It is associated with adverse outcome if flow is not restored. Objective of this study was to find safety, effectiveness and outcome of intracoronary nikorandil (IC) administered using perforated balloon technique (PBT) to reverse NRF. METHOD: 2-4 mg of nicorandil was diluted with 5 ml of normal saline and administered using PBT over 5-minute. Its effectiveness was evaluated after 10 minute qualitatively using TIMI flow and quantitatively corrected TIMI frame count (cTFC) method. RESULT: Study comprised of 84 patients (out of 1789 patients undergoing PCI between January 2019 and February 2020). Their mean age was 57.8±17.9 years. Following PBT, TIMI III flow was successfully normalized in 71 subjects (84.5%), ten (12%) patients had TIMI II flow and it was not successful in three (3.5%) patients. TIMI flow grade got bettered from 1.03 to 2.58 and cTIMI frame count regressed from 52.9±11 to 16.5±5 (P < 0.001). PBT was well tolerated except short lived drop in blood pressure (n=10; 11.9%). CONCLUSION: This study, for the first time to the best our knowledge, demonstrated that PBT mediated intracoronary administration of nikorandil distally was rapid, safe, and efficacious method to deal with NRF.

3.
ARYA Atheroscler ; 17(1): 1-4, 2021 Jan.
Article in English | MEDLINE | ID: mdl-34703484

ABSTRACT

BACKGROUND: Coronary angiography and intervention through transradial approach is becoming default approach because of infrequent local site complications. Although pseudoaneurysm is a well described complication for femoral access, it is extremely rare in transradial access. CASE REPORT: Our patient was 68-year old female who had presented with pulsatile, painful, and gradually increasing swelling over lower part of right forearm near wrist joint for past 8-weeks following coronary angiography through right radial route. Swelling did not resolve following manual compression. It was diagnosed as pseudoaneurysm arising from right radial artery by duplex ultrasound. It was successfully excluded by deploying 3.5x18mm Graftmaster covered stent (Abott Vascular, USA) through right transbrachial route. Ultrasonography next day revealed partially thrombosed and completely excluded pseudoaneurysm with swelling completely disappearing at 6 weeks with patency maintained at one year. CONCLUSION: With increasing use of transradial access, more cases of radial pseudoaneurysm are likely to surface which can be prevented following a proper haemostatic protocol. To best of our knowledge, it is first ever report of percutaneous endovascular exclusion using covered stent of radial pseudoaneurysm through transbrachial approach.

SELECTION OF CITATIONS
SEARCH DETAIL
...