Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasonics ; 141: 107332, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38718460

ABSTRACT

BACKGROUND: Stroke is the second leading cause of death across the globe. Early screening and risk detection could provide early intervention and possibly prevent its incidence. Imaging modalities, including 1D-Transcranial Doppler Ultrasound (1D-TCD) or Transcranial Color-code sonography (TCCS), could only provide low spatial resolution or 2D image information, respectively. Notably, 3D imaging modalities including CT have high radiation exposure, whereas MRI is expensive and cannot be adopted in patients with implanted devices. This study proposes an alternative imaging solution for reconstructing 3D Doppler ultrasound geared towards providing a screening tool for the 3D vessel structure of the brain. METHODS: The system comprises an ultrasound phased array attached to a servo motor, which can rotate 180˚ at a speed of 2˚/s. We extracted the color Doppler ROI from the image before reconstructing it into a 3D view using a customized pixel-based algorithm. Different vascular diameters, flow velocity, and depth were tested using a vascular phantom with a pumped flow to confirm the system for imaging blood flow. These variables were set to mimic the vessel diameter, flow speed, and depth of the Circle of Willis (CoW) during a transcranial screening. RESULTS AND CONCLUSIONS: The lower values of absolute error and ratio were found in the larger vascular channels, and vessel diameter overrepresentation was observed. Under different flow velocities, such diameter overrepresentation in the reconstructed flow did not change much; however, it did change with different depths. Meanwhile, the setting of the velocity scale and the color gain affected the dimension of reconstructed objectives. Moreover, we presented a 3D image of CoW from a subject to demonstrate its potential. The findings of this work can provide a good reference for further studies on the reconstruction of the CoW or other blood vessels using Doppler imaging.


Subject(s)
Circle of Willis , Imaging, Three-Dimensional , Phantoms, Imaging , Ultrasonography, Doppler, Transcranial , Circle of Willis/diagnostic imaging , Imaging, Three-Dimensional/methods , Ultrasonography, Doppler, Transcranial/methods , Humans , Algorithms , Cerebrovascular Circulation , Blood Flow Velocity
2.
J Clin Ultrasound ; 51(7): 1212-1222, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37334435

ABSTRACT

AIMS: To investigate the reliability, validity, and level of evidence of applying ultrasound in assessing the lower-limb muscles of patients with cerebral palsy (CP). METHOD: Publications in Medline, PubMed, Web of Science, and Embase were searched on May 10, 2023, to identify and examine relevant studies investigating the reliability/validity of ultrasound in evaluating the architecture of CP lower-limb muscles systematically, following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis 2020 guidelines. RESULTS: Out of 897 records, 9 publications with 111 CP participants aged 3.8-17.0 years were included (8 focused on intra-rater and inter-rater reliability, 2 focused on validity, and 4 were with high quality). The ultrasound-based measurements of muscle thickness (intra-rater only), muscle length, cross-sectional area, muscle volume, fascicle length, and pennation angle showed high reliability, with the majority of intraclass correlation coefficient (ICC) values being larger than 0.9. Moderate-to-good correlations between ultrasound and magnetic resonance imaging measurements existed in muscle thickness and cross-sectional area (0.62 ≤ ICC ≤ 0.82). INTERPRETATION: Generally, ultrasound has high reliability and validity in evaluating the CP muscle architecture, but this is mainly supported by moderate and limited levels of evidence. More high-quality future studies are needed.


Subject(s)
Cerebral Palsy , Humans , Cerebral Palsy/diagnostic imaging , Reproducibility of Results , Muscle, Skeletal/diagnostic imaging , Lower Extremity/diagnostic imaging , Ultrasonography/methods
3.
Sensors (Basel) ; 21(11)2021 May 26.
Article in English | MEDLINE | ID: mdl-34073586

ABSTRACT

(1) Background: Ultrasound provides a radiation-free and portable method for assessing swallowing. Hyoid bone locations and displacements are often used as important indicators for the evaluation of swallowing disorders. However, this requires clinicians to spend a great deal of time reviewing the ultrasound images. (2) Methods: In this study, we applied tracking algorithms based on deep learning and correlation filters to detect hyoid locations in ultrasound videos collected during swallowing. Fifty videos were collected from 10 young, healthy subjects for training, evaluation, and testing of the trackers. (3) Results: The best performing deep learning algorithm, Fully-Convolutional Siamese Networks (SiamFC), proved to have reliable performance in getting accurate hyoid bone locations from each frame of the swallowing ultrasound videos. While having a real-time frame rate (175 fps) when running on an RTX 2060, SiamFC also achieved a precision of 98.9% at the threshold of 10 pixels (3.25 mm) and 80.5% at the threshold of 5 pixels (1.63 mm). The tracker's root-mean-square error and average error were 3.9 pixels (1.27 mm) and 3.3 pixels (1.07 mm), respectively. (4) Conclusions: Our results pave the way for real-time automatic tracking of the hyoid bone in ultrasound videos for swallowing assessment.


Subject(s)
Deep Learning , Deglutition Disorders , Deglutition , Fluoroscopy , Humans , Hyoid Bone/diagnostic imaging
4.
Sensors (Basel) ; 20(19)2020 Sep 26.
Article in English | MEDLINE | ID: mdl-32993105

ABSTRACT

BACKGROUND: Available methods for studying muscle dynamics, including electromyography (EMG), mechanomyography (MMG) and M-mode ultrasound, have limitations in terms of spatial resolution. METHODS: This study developed a novel method/protocol of two-dimensional mapping of muscle motion onset using ultrafast ultrasound imaging, i.e., sono-mechano-myo-graphy (SMMG). The developed method was compared with the EMG, MMG and force outputs of tibialis anterior (TA) muscle during ankle dorsiflexion at different percentages of maximum voluntary contraction (MVC) force in healthy young adults. RESULTS: Significant differences between all pairwise comparisons of onsets were identified, except between SMMG and MMG. The EMG onset significantly led SMMG, MMG and force onsets by 40.0 ± 1.7 ms (p < 0.001), 43.1 ± 5.2 ms (p < 0.005) and 73.0 ± 4.5 ms (p < 0.001), respectively. Muscle motion also started earlier at the middle aponeurosis than skin surface and deeper regions when viewed longitudinally (p < 0.001). No significant effect of force level on onset delay was found. CONCLUSIONS: This study introduced and evaluated a new method/protocol, SMMG, for studying muscle dynamics and demonstrated its feasibility for muscle contraction onset research. This novel technology can potentially provide new insights for future studies of neuromuscular diseases, such as multiple sclerosis and muscular dystrophy.


Subject(s)
Isometric Contraction , Muscle Contraction , Muscle, Skeletal , Myography/methods , Ultrasonography , Electromyography , Humans , Muscle, Skeletal/diagnostic imaging , Young Adult
5.
Sensors (Basel) ; 19(1)2019 Jan 07.
Article in English | MEDLINE | ID: mdl-30621103

ABSTRACT

BACKGROUND: Motion capture and analyzing systems are essential for understanding locomotion. However, the existing devices are too cumbersome and can be used indoors only. A newly-developed wearable motion capture and measurement system with multiple sensors and ultrasound imaging was introduced in this study. METHODS: In ten healthy participants, the changes in muscle area and activity of gastrocnemius, plantarflexion and dorsiflexion of right leg during walking were evaluated by the developed system and the Vicon system. The existence of significant changes in a gait cycle, comparison of the ankle kinetic data captured by the developed system and the Vicon system, and test-retest reliability (evaluated by the intraclass correlation coefficient, ICC) in each channel's data captured by the developed system were examined. RESULTS: Moderate to good test-retest reliability of various channels of the developed system (0.512 ≤ ICC ≤ 0.988, p < 0.05), significantly high correlation between the developed system and Vicon system in ankle joint angles (0.638R ≤ 0.707, p < 0.05), and significant changes in muscle activity of gastrocnemius during a gait cycle (p < 0.05) were found. CONCLUSION: A newly developed wearable motion capture and measurement system with ultrasound imaging that can accurately capture the motion of one leg was evaluated in this study, which paves the way towards real-time comprehensive evaluation of muscles and joint motions during different activities in both indoor and outdoor environments.


Subject(s)
Locomotion/physiology , Muscle, Skeletal/physiology , Walking/physiology , Wearable Electronic Devices , Adult , Biomechanical Phenomena/physiology , Female , Gait/physiology , Humans , Male , Monitoring, Physiologic
6.
Oncogenesis ; 7(5): 44, 2018 May 25.
Article in English | MEDLINE | ID: mdl-29799025

ABSTRACT

Hepatocellular carcinoma (HCC), accounting for 90% of primary liver cancer, is a lethal malignancy that is tightly associated with chronic hepatitis B virus (HBV) infection. HBV encodes a viral onco-protein, transactivator protein X (HBx), which interacts with proteins of hepatocytes to promote oncogenesis. Our current study focused on the interaction of HBx with a transcription factor, hypoxia-inducible factor-1α (HIF-1α), which is stabilized by low O2 condition (hypoxia) and is found to be frequently overexpressed in HCC intra-tumorally due to poor blood perfusion. Here, we showed that overexpression of HBx by tetracycline-inducible systems further stabilized HIF-1α under hypoxia in HBV-negative HCC cell lines. Reversely, knockdown of HBx reduced HIF-1α protein stabilization under hypoxia in HBV-positive HCC cell lines. More intriguingly, overexpression of HBx elevated the mRNA and protein expression of a family of HIF-1α target genes, the lysyl oxidase (LOX) family in HCC. The LOX family members function to cross-link collagen in the extracellular matrix (ECM) to promote cancer progression and metastasis. By analyzing the collagens under scanning electron microscope, we found that collagen fibers were significantly smaller in size when incubated with conditioned medium from HBx knockdown HCC cells as compared to control HCC cells in vitro. Transwell invasion assay further revealed that less cells were able to invade through the matrigel which was pre-treated with conditioned medium from HBx knockdown HCC cells as compared to control HCC cells. Orthotopic and subcutaneous HCC models further showed that knockdown of HBx in HCC cells reduced collagen crosslinking and stiffness in vivo and repressed HCC growth and metastasis. Taken together, our in vitro and in vivo studies showed the HBx remodeled the ECM through HIF-1α/LOX pathway to promote HCC metastasis.

SELECTION OF CITATIONS
SEARCH DETAIL
...