Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 15(5): 11499-510, 2015 May 19.
Article in English | MEDLINE | ID: mdl-25996510

ABSTRACT

We propose a surface plasmon resonance (SPR) sensor based on photonic crystal fiber (PCF) with selectively filled analyte channels. Silver is used as the plasmonic material to accurately detect the analytes and is coated with a thin graphene layer to prevent oxidation. The liquid-filled cores are placed near to the metallic channel for easy excitation of free electrons to produce surface plasmon waves (SPWs). Surface plasmons along the metal surface are excited with a leaky Gaussian-like core guided mode. Numerical investigations of the fiber's properties and sensing performance are performed using the finite element method (FEM). The proposed sensor shows maximum amplitude sensitivity of 418 Refractive Index Units (RIU-1) with resolution as high as 2.4 × 10(-5) RIU. Using the wavelength interrogation method, a maximum refractive index (RI) sensitivity of 3000 nm/RIU in the sensing range of 1.46-1.49 is achieved. The proposed sensor is suitable for detecting various high RI chemicals, biochemical and organic chemical analytes. Additionally, the effects of fiber structural parameters on the properties of plasmonic excitation are investigated and optimized for sensing performance as well as reducing the sensor's footprint.


Subject(s)
Graphite/chemistry , Silver/chemistry , Surface Plasmon Resonance/instrumentation , Equipment Design , Materials Testing , Optical Fibers , Optics and Photonics
2.
Appl Opt ; 49(20): 3956-9, 2010 Jul 10.
Article in English | MEDLINE | ID: mdl-20648173

ABSTRACT

We demonstrate a simple configuration for generating a double Brillouin frequency shift through the circulation of an odd-order Brillouin Stokes signal. It is operated based on cascaded Brillouin scattering in single-mode optical fibers that behave as the Brillouin gain media. A four-port circulator is incorporated into the setup to circulate the odd-order Brillouin Stokes signal in the fiber. It thus initiates a higher order Brillouin Stokes signal, which is double Brillouin frequency downshifted from the input signal. For the 5 km long fiber, the Brillouin pump power at 23 mW gives a clean output spectrum with 30 dB sideband suppression ratio. The output signal is 0.174 nm or approximately 21.7 GHz downshifted from the input signal.

SELECTION OF CITATIONS
SEARCH DETAIL
...