Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Orthop J Sports Med ; 9(11): 23259671211050435, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34778476

ABSTRACT

BACKGROUND: Glenoid reconstruction with distal tibial allograft (DTA) is a known surgical option for treating recurrent glenohumeral instability with anterior glenoid bone loss; however, biomechanical analysis has yet to determine how graft variability and fixation options alter the torque of screw insertion and load to failure. HYPOTHESIS: It was hypothesized that retention of the lateral cortex of the DTA graft and the presence of a washer with the screw will significantly increase the maximum screw placement torque as well as the load to failure. STUDY DESIGN: Controlled laboratory study. METHODS: Whole, fresh distal tibias were used to harvest 28 DTA grafts, half of which had the lateral cortex removed and half of which had the lateral cortex intact. The grafts were secured to polyurethane solid foam blocks with a 2-mm epoxy laminate to simulate a glenoid with an intact posterior glenoid cortex. Grafts underwent fixation with 4.0-mm cannulated drills, and screws and washers were used for half of each group of grafts while screws alone were used for the other half, creating 4 equal groups of 7 samples each. A digital torque-measuring screwdriver recorded peak torque for screw insertion. Constructs were then tested in compression with a uniaxial materials testing system and loaded in displacement control at 100 mm/min until at least 3 mm of displacement occurred. Ultimate load was defined as the load sustained at clinical failure. RESULTS: The use of a washer significantly improved the ultimate torque that could be applied to the screws (+cortex and +washer = 12.42 N·m [SE, 0.82]; -cortex and +washer = 10.54 N·m [SE, 0.59]) (P < .0001), whereas the presence of the native bone cortex did not have a significant effect (+cortex and -washer = 7.83 N·m [SE, 0.40]; -cortex and -washer = 8.03 N·m [SE, 0.56]) (P = .181). CONCLUSION: In a hybrid construct of fresh cadaveric DTA grafts secured to a foam block glenoid model, the addition of washers was more effective than the retention of the lateral distal tibial cortex for both load to failure and peak torque during screw insertion. CLINICAL RELEVANCE: This biomechanical study is relevant to the surgeon when choosing a graft and selecting fixation options during glenoid reconstruction with a DTA graft.

2.
J Orthop ; 21: 384-389, 2020.
Article in English | MEDLINE | ID: mdl-32921946

ABSTRACT

OBJECTIVE: Scapular notching is a unique radiographic sequela of reverse total shoulder arthroplasty (rTSA) with unclear long-term clinical consequences. METHODS: Our retrospective review of a single surgeon, single implant, primary rTSA database investigates the incidence of scapular notching at 2 and 5-year follow-up. Various patient outcome scores were also obtained. RESULTS: Of 158 primary rTSAs performed, 82 (52%) patients completed 2-year and subsequent 5-year follow-up. The incidence of scapular notching at 2 and 5-years was 11.9% and 19.5%, respectively. CONCLUSION: Scapular notching negatively affects validated post-operative outcome scores, active range of motion and total complications, and furthermore increases with time.

3.
Arthroscopy ; 36(6): 1517-1522, 2020 06.
Article in English | MEDLINE | ID: mdl-32057985

ABSTRACT

PURPOSE: The purpose of this study was to determine if there are significant side-to-side anthropometric differences between paired glenoids. METHODS: Forty-six matched-pair cadaver glenoids were harvested, and their glenoid heights (GHs) and glenoid widths (GWs) were measured with digital calipers. The glenoid surface area was calculated using the standard assumption that the inferior two-thirds of the glenoid is a perfect circle. RESULTS: There was a statistically significant difference between matched-pair GHs of 0.96 ± 3.07 mm (P = .020) and GWs of 0.46 ± 1.64 mm (P = .033). There was a significant difference of glenoid cavity area of 20.30 ± 81.53 mm2 (P = .044), or a difference of ∼3%. A total of 4 of 46 pairs of glenoids (8.6%) showed a difference in width >3 mm. CONCLUSIONS: This study demonstrates the fallacy of use of the contralateral glenoid in measuring glenoid bone loss. Although many paired samples exhibited similar side-to-side glenoid measurements, the number of cadaveric pairs that showed differences of >3 mm was substantial. Caution should be taken when using calculation methods that include this assumption for surgical decision making, as surface area, GW, and GH were all shown to have statistically significant side-to-side differences in their measurements. CLINICAL RELEVANCE: Many methods exist for measuring glenoid bone loss after anterior shoulder dislocation, but some of the current methods may be inaccurate and lead to unreliable estimations.


Subject(s)
Glenoid Cavity/pathology , Joint Instability/surgery , Shoulder Joint/surgery , Bone Resorption/pathology , Cadaver , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...