Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 79(3): 033106, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18376996

ABSTRACT

We demonstrate the ability to excite and monitor many whispering gallery modes (WGMs) of a microsphere resonator simultaneously in order to make broadband optical absorbance measurements. The 340 microm diameter microsphere is placed in a microfluidic channel. A hemispherical prism is used for coupling the WGMs into and out of the microsphere. The flat surface of the prism seals the microfluidic channel. The slight nonsphericity in the microsphere results in coupling to precessed modes whose emission is spatially separated from the reflected excitation light. The evanescent fields of the light trapped in WGMs interact with the surrounding environment. The change in transmission observed in the precessed modes is used to determine the absorbance of the surrounding environment. In contrast to our broadband optical absorbance measurements, previous WGM sensors have used only a single narrow mode to measure properties such as refractive index. With the microfluidic cell, we have measured the absorbance of solutions of dyes (lissamine green B, sunset yellow, orange G, and methylene blue), aromatic molecules (benzylamine and benzoic acid), and biological molecules (tryptophan, phenylalanine, tyrosine, and o-phospho-L-tyrosine) at visible and ultraviolet wavelengths. The microsphere surface was reacted with organosilane molecules to attach octadecyl groups, amino groups, and fluorogroups to the surface. Both electrostatic and hydrophobic interactions were observed between the analytes and the microsphere surface, as indicated by changes in the measured effective pathlength with different organosilanes. For a given analyte and coated microsphere, the pathlength measurement was repeatable within a few percent. Methylene blue dye had a very strong interaction with the surface and pathlengths of several centimeters were measured. Choosing an appropriate surface coating to interact with a specific analyte should result in the highest sensitivity detection.

2.
Opt Lett ; 27(5): 312-4, 2002 Mar 01.
Article in English | MEDLINE | ID: mdl-18007787

ABSTRACT

With the implementation of a fast-bandwidth servo, along with improved laser construction and associated better passive stability, we have achieved subfemtosecond relative timing jitter between two independent, actively synchronized, mode-locked Ti:sapphire lasers. Timing jitter of 0.58 fs is obtained with a 160-Hz observation bandwidth over several seconds. Within a 2-MHz observation bandwidth, the timing jitter is 1.75 fs. Excellent repeatability and rapid speed in setting an arbitrary time delay between two pulses are also demonstrated.

SELECTION OF CITATIONS
SEARCH DETAIL
...