ABSTRACT
PURPOSE: To quantify abnormalities in the peripapillary microvasculature in eyes with primary open-angle glaucoma (POAG) and paracentral visual field (VF) loss. DESIGN: Prospective, cross-sectional study. PARTICIPANTS: Thirty-three POAG patients, including 15 with paracentral VF loss and 18 with peripheral VF loss, and 31 control participants underwent swept-source OCT angiography (OCTA) of the peripapillary region. METHODS: The POAG groups were matched by VF mean deviation (MD). The peripapillary microvasculature from the internal limiting membrane to the retinal nerve fiber layer (RNFL) interface was quantified within a 0.70-mm annulus around Bruch's membrane opening after removal of large vessels. Both vessel density (VD) and the integrated OCTA by ratio analysis signal (IOS) suggestive of flow were measured. Regional VD and IOS were measured from the affected hemisphere corresponding to the VF hemifield of more severe loss, which was used to calculate the paracentral total deviation (PaTD), or total deviation within the central 10°. One eye per participant was included. MAIN OUTCOME MEASURES: Difference in peripapillary OCTA measurements between paracentral and peripheral VF loss groups and correlation of peripapillary VD and IOS with PaTD. RESULTS: The POAG groups had matched VF MD (-3.1 ± 2.5 dB paracentral vs. -2.3 ± 2.0 dB peripheral; P = 0.31), did not differ in average RNFL thickness (71.1 ± 14.7 µm vs. 78.1 ± 15.0 µm; P = 0.55), but differed in age (59.2 ± 9.6 years paracentral vs. 67.4 ± 6.6 years peripheral; P = 0.02). Compared with control participants, both paracentral and peripheral VF loss groups showed reduced VD (P < 0.001 and P = 0.009, respectively) and IOS (P < 0.001 and P = 0.01, respectively) in the affected hemisphere. Compared with POAG eyes with peripheral VF loss, the paracentral group showed reduced peripapillary VD (38.0 ± 2.0%, 35.0 ± 2.2%, respectively; P = 0.001) and IOS (44.3 ± 3.1%, 40.4 ± 4.0%, respectively; P = 0.02) in the affected hemisphere. Among all POAG eyes, peripapillary VD and IOS of the affected hemisphere correlated significantly with functional measurement of paracentral loss (PaTD, r = 0.40, P = 0.02; r = 0.45, P = 0.008; respectively). These correlations remained significant after adjusting for age (r = 0.41, P = 0.02; r = 0.47, P = 0.01; respectively). CONCLUSIONS: Regional peripapillary microvasculature showed decreased VD and flow in POAG with paracentral loss, supporting its importance in this glaucoma subtype.
Subject(s)
Glaucoma, Open-Angle , Optic Disk , Aged , Cross-Sectional Studies , Glaucoma, Open-Angle/diagnosis , Humans , Intraocular Pressure , Microvessels/diagnostic imaging , Middle Aged , Nerve Fibers , Optic Disk/diagnostic imaging , Prospective Studies , Retinal Ganglion Cells , Retinal Vessels/diagnostic imaging , Tomography, Optical Coherence , Visual FieldsABSTRACT
PURPOSE: To assess outcomes and glaucoma management in eyes with aniridia following Boston type 1 Keratoprosthesis (KPro) implantation. DESIGN: Retrospective, interventional comparative case series. METHODS: The population included patients with aniridia and patients with other preoperative diagnoses (excluding Stevens-Johnson syndrome, mucous membrane pemphigoid, and congenital disorders) who underwent KPro implantation at Massachusetts Eye and Ear with at least 2 years of follow-up. One eye per patient was selected based on the longer follow-up time. The main outcome was intermediate and long-term outcomes related to glaucoma. RESULTS: The aniridia (n = 22) and comparison (n = 61) groups had similar preoperative visual acuity (VA, mean ± standard deviation, 1.86 ± 0.52 logMAR, P = .33) and follow-up time (65.6 ± 26.3 months, P = .25). Before KPro implantation, eyes with aniridia had more glaucoma (76.2%) and glaucoma surgery (57.1%) than comparison eyes (51.8%, P = .053; 23.2%, P = .005, respectively). More Ahmed valves were co-implanted with KPro in aniridia (47.6%) vs comparison eyes (17.9%, P = .008). At final follow-up, more aniridia eyes had glaucoma (90.5%) than comparison eyes (64.3%, P = .02), but the 2 groups had similar percentages of eyes with cup-to-disc ratio (CDR) >0.8 (23.8% vs. 30.4%, P = .57) or CDR progression of ≥0.2 (42.9% vs 44.6%, P = .89, respectively). None of the eyes with prophylactic tube implantation developed glaucoma. Eyes with and without aniridia did not differ in post-KPro VA improvement (72.7%, 72.1%, P = .96), and final VA (1.28 ± 0.79 logMAR, 1.23 ± 0.98 logMAR, P = .51). CONCLUSION: Despite a higher glaucoma prevalence, eyes with aniridia achieved similar VA as comparison eyes with more than 5 years of mean follow-up time. Boston KPro offers satisfactory visual rehabilitation in aniridia when glaucoma is managed aggressively.
Subject(s)
Aniridia/complications , Artificial Organs , Corneal Diseases/surgery , Glaucoma Drainage Implants , Glaucoma/surgery , Postoperative Complications , Prostheses and Implants , Adult , Aged , Cornea , Female , Follow-Up Studies , Glaucoma/etiology , Glaucoma/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Prosthesis Implantation , Retrospective Studies , Tonometry, Ocular , Visual Acuity/physiologyABSTRACT
PURPOSE: To quantitatively evaluate the angle anatomy in eyes with the Boston type I keratoprosthesis (B-KPro) differing in the back plate (BP) material and size using anterior segment optical coherence tomography. METHODS: B-KPro eyes with poly(methyl methacrylate) (PMMA) (7.0 and 8.5 mm) and titanium (7.0, 8.5, and 9.5 mm) BPs were imaged with anterior segment optical coherence tomography. The angle opening distance at 500 µm from the scleral spur (AOD500), trabecular iris surface area at 500 µm from the scleral spur (TISA500), and trabecular iris angle at 500 µm from the scleral spur (TIA500) were measured. Among the visible quadrants, the average, the temporal, the widest, and the narrowest angle of each eye were included in the analysis. Average time between B-KPro implantation and imaging was 7.5 ± 1.4 years for a PMMA BP and 2.4 ± 2.3 years for a titanium BP (P < 0.0001). RESULTS: We analyzed 17 B-KPro eyes with PMMA BPs and 24 B-KPro eyes with titanium BPs. The average AOD500 (394.1 ± 226.9 vs. 454.5 ± 255.6 µm, P = 0.44), average TIA500 (26.2 ± 14.2 vs. 29.8 ± 13.9 degrees, P = 0.43), and average TISA500 (0.15 ± 0.08 vs. 0.17 ± 0.10 µm, P = 0.52) were not statistically different between eyes with PMMA and titanium BPs, nor were the temporal, the narrowest, and the widest angle measurements of each eye (all P > 0.05). Similarly, no significant differences were found between the angle measurements of B-KPro eyes with a titanium BP diameter of 8.5 or 9.5 mm (all P > 0.05). CONCLUSIONS: We successfully visualized the angle anatomy in 66.1% of the imaged eyes, including all BPs studied. Neither the material nor the size of the B-KPro BP had a significant impact on the angle anatomy.