Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Cont Lens Anterior Eye ; : 102176, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38735811

ABSTRACT

CLINICAL RELEVANCE: Digital eye strain (DES) is a condition encompassing visual and ocular symptoms that may arise due to the prolonged use of digital devices. The 2023 Tear Film Ocular Surface Lifestyle report defined DESas"the development or exacerbation of recurrent ocular symptoms and / or signs related specifically to digital device screen viewing". Studies vary as to the prevalence of DES with some reporting values as low as 10 % and some reporting values over 90 %, however no study has examined the prevalence of DES in the UK or Ireland (UK&I). PURPOSE: To determine the prevalence of DES amongst adults who work with digital devices in UK&I, their symptoms and ameliorative approaches taken by those affected. METHODS: A web-based survey of digital device users was conducted. Adults who used a device for at least 1 h per day for work purposes were eligible to participate. The questionnaire was designed to determine the prevalence of DES, daily device usage, musculoskeletal and ocular symptoms, how they manage their symptoms and eye care history. RESULTS: Based on a Computer Vision Syndrome Questionnaire score ≥ 6, the occurrence of DES was high at 62.6 %. The mean number of hours devices were used for was 9.7 h. Musculoskeletal symptoms were reported by 94.3 % of users and ocular symptoms by 89.5 % with symptoms most likely to occur with those working from home. 8.1 % of respondents considered their symptoms significant enough to affect their work. CONCLUSION: This study provides a valuable insight into DES in digital device users in UK&I and is the first of its kind to be completed. It shows, that while the level of DES is high in device users, at 62.6 %, the actual effect or consequences of it on many does not appear to be significant.

2.
Cont Lens Anterior Eye ; : 102156, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38641525

ABSTRACT

It is important to be able to measure the range of clear focus in clinical practice to advise on presbyopia correction techniques and to optimise the correction power. Both subjective and objective techniques are necessary: subjective techniques (such as patient reported outcome questionnaires and defocus curves) assess the impact of presbyopia on a patient and how the combination of residual objective accommodation and their natural DoF work for them; objective techniques (such as autorefraction, corneal topography and lens imaging) allow the clinician to understand how well a technique is working optically and whether it is the right choice or how adjustments can be made to optimise performance. Techniques to assess visual performance and adverse effects must be carefully conducted to gain a reliable end-point, considering the target size, contrast and illumination. Objective techniques are generally more reliable, can help to explain unexpected subjective results and imaging can be a powerful communication tool with patients. A clear diagnosis, excluding factors such as binocular vision issues or digital eye strain that can also cause similar symptoms, is critical for the patient to understand and adapt to presbyopia. Some corrective options are more permanent, such as implanted inlays / intraocular lenses or laser refractive surgery, so the optics can be trialled with contact lenses in advance (including differences between the eyes) to better communicate with the patient how the optics will work for them so they can make an informed choice.

3.
Eye (Lond) ; 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38509183

ABSTRACT

With the advances in smartphone and tablet screens, as well as their processing power and software, mobile apps have been developed reporting to assess visual function. This review assessed those mobile apps that have been evaluated in the scientific literature to measure visual acuity, reading metrics, contrast sensitivity, stereoacuity, colour vision and visual fields; these constitute just a small percentage of the total number of mobile apps reporting to measure these metrics available for tablets and smartphones. In general, research suggests that most of the mobile apps evaluated can accurately mimic most traditionally paper-based tests of visual function, benefitting from more even illumination from the backlit screen and aspects such as multiple tests and versions (to minimise memorisation) being available on the same equipment. Some also utilise the in-built device sensors to monitor aspects such as working distance and screen tilt. As the consequences of incorrectly recording visual function and using this to inform clinical management are serious, clinicians must check on the validity of a mobile app before adopting it as part of clinical practice.

4.
Ophthalmic Physiol Opt ; 44(3): 483-490, 2024 May.
Article in English | MEDLINE | ID: mdl-38372370

ABSTRACT

PURPOSE: Previous research has shown that accommodation deficits are common in individuals with Down syndrome (DS), but the origin and mechanisms behind these deficits are still unknown. The aim of this study was to investigate the characteristics of different ocular structures involved in accommodation, in particular the ciliary muscle (CM), in a population of individuals with DS to further understand this deficit and its mechanisms. METHODS: Thirty-two volunteer participants of pre-presbyopic age with (n = 16) and without DS (n = 16) were recruited. Temporal and nasal images of the CM were acquired using anterior segment optical coherence tomography (AS-OCT) while participants fixated an eccentrically located target. Analysis of CM parameters was undertaken using validated semi-automated software. Axial length, anterior chamber depth, lens thickness and corneal curvature were obtained with the Topcon Aladdin Optical Biometer and Corneal Topographer. Non-cycloplegic refractive error and accommodative ability were obtained with an open-field autorefractor and dynamic retinoscopy, respectively. Independent t-tests were conducted to determine differences in CM and other anterior segment parameters between participants with and without DS. RESULTS: No significant differences were found in the CM parameters studied between participants with and without DS (p > 0.05). In contrast, significant differences were found in visual acuity (p < 0.001), accommodative response (p < 0.001) and corneal curvature (K1 p = 0.003 and K2 p < 0.001) between participants with and without DS. CONCLUSIONS: Despite having poorer accommodation, pre-presbyopic adults with DS do not have a different CM morphology to that found in typically developing adults. These findings suggest that the accommodative deficit found in this population is not due to a mechanical deficit of the CM.


Subject(s)
Down Syndrome , Lens, Crystalline , Adult , Humans , Lens, Crystalline/anatomy & histology , Ciliary Body/diagnostic imaging , Ciliary Body/anatomy & histology , Ciliary Body/physiology , Accommodation, Ocular , Tomography, Optical Coherence/methods , Muscles
5.
Ophthalmic Physiol Opt ; 44(3): 641-671, 2024 May.
Article in English | MEDLINE | ID: mdl-38404172

ABSTRACT

PURPOSE: With the introduction of ChatGPT, artificial intelligence (AI)-based large language models (LLMs) are rapidly becoming popular within the scientific community. They use natural language processing to generate human-like responses to queries. However, the application of LLMs and comparison of the abilities among different LLMs with their human counterparts in ophthalmic care remain under-reported. RECENT FINDINGS: Hitherto, studies in eye care have demonstrated the utility of ChatGPT in generating patient information, clinical diagnosis and passing ophthalmology question-based examinations, among others. LLMs' performance (median accuracy, %) is influenced by factors such as the iteration, prompts utilised and the domain. Human expert (86%) demonstrated the highest proficiency in disease diagnosis, while ChatGPT-4 outperformed others in ophthalmology examinations (75.9%), symptom triaging (98%) and providing information and answering questions (84.6%). LLMs exhibited superior performance in general ophthalmology but reduced accuracy in ophthalmic subspecialties. Although AI-based LLMs like ChatGPT are deemed more efficient than their human counterparts, these AIs are constrained by their nonspecific and outdated training, no access to current knowledge, generation of plausible-sounding 'fake' responses or hallucinations, inability to process images, lack of critical literature analysis and ethical and copyright issues. A comprehensive evaluation of recently published studies is crucial to deepen understanding of LLMs and the potential of these AI-based LLMs. SUMMARY: Ophthalmic care professionals should undertake a conservative approach when using AI, as human judgement remains essential for clinical decision-making and monitoring the accuracy of information. This review identified the ophthalmic applications and potential usages which need further exploration. With the advancement of LLMs, setting standards for benchmarking and promoting best practices is crucial. Potential clinical deployment requires the evaluation of these LLMs to move away from artificial settings, delve into clinical trials and determine their usefulness in the real world.


Subject(s)
Artificial Intelligence , Ophthalmology , Humans , Clinical Decision-Making , Eye , Judgment
7.
Ophthalmic Physiol Opt ; 43(6): 1562-1570, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37476960

ABSTRACT

PURPOSE: ChatGPT is an artificial intelligence language model, which uses natural language processing to simulate human conversation. It has seen a wide range of applications including healthcare education, research and clinical practice. This study evaluated the accuracy of ChatGPT in providing accurate and quality information to answer questions on myopia. METHODS: A series of 11 questions (nine categories of general summary, cause, symptom, onset, prevention, complication, natural history, treatment and prognosis) were generated for this cross-sectional study. Each question was entered five times into fresh ChatGPT sessions (free from influence of prior questions). The responses were evaluated by a five-member team of optometry teaching and research staff. The evaluators individually rated the accuracy and quality of responses on a Likert scale, where a higher score indicated greater quality of information (1: very poor; 2: poor; 3: acceptable; 4: good; 5: very good). Median scores for each question were estimated and compared between evaluators. Agreement between the five evaluators and the reliability statistics of the questions were estimated. RESULTS: Of the 11 questions on myopia, ChatGPT provided good quality information (median scores: 4.0) for 10 questions and acceptable responses (median scores: 3.0) for one question. Out of 275 responses in total, 66 (24%) were rated very good, 134 (49%) were rated good, whereas 60 (22%) were rated acceptable, 10 (3.6%) were rated poor and 5 (1.8%) were rated very poor. Cronbach's α of 0.807 indicated good level of agreement between test items. Evaluators' ratings demonstrated 'slight agreement' (Fleiss's κ, 0.005) with a significant difference in scoring among the evaluators (Kruskal-Wallis test, p < 0.001). CONCLUSION: Overall, ChatGPT generated good quality information to answer questions on myopia. Although ChatGPT shows great potential in rapidly providing information on myopia, the presence of inaccurate responses demonstrates that further evaluation and awareness concerning its limitations are crucial to avoid potential misinterpretation.

8.
BMJ Open Ophthalmol ; 8(1)2023 01.
Article in English | MEDLINE | ID: mdl-37278419

ABSTRACT

Presbyopia occurs when the physiologically normal age-related reduction in the eyes focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual's requirements. Hence, it is more about the impact it has on an individual's visual ability to function in their environment to maintain their lifestyle than a measured loss of focusing ability. Presbyopia has a significant impact on an individual's quality of life and emotional state. While a range of amelioration strategies exist, they are often difficult to access in the developing world and prescribing is generally not optimal even in developed countries. This review identified the need for a standardised definition of presbyopia to be adopted. An appropriate battery of tests should be applied in evaluating presbyopic management options and the results of clinical trials should be published (even if unsuccessful) to accelerate the provision of better outcomes for presbyopes.


Subject(s)
Presbyopia , Humans , Presbyopia/diagnosis , Quality of Life , Eye , Electric Power Supplies
9.
Clin Optom (Auckl) ; 15: 9-27, 2023.
Article in English | MEDLINE | ID: mdl-36647552

ABSTRACT

Artificial tears are the mainstay of dry eye disease management, but also have a role in corneal abrasion and wound healing, pain and inflammation management, conjunctivitis, keratitis, contact lens rewetting and removal, and foreign body removal. A systematic review of randomized controlled trials (PROSPERO registration CRD42022369619) comparing the efficacy of artificial tears in patients with dry eye to inform prescribing choices using Web of Science, PubMed and Medline databases identified 64 relevant articles. There is good evidence that artificial tears improve symptoms of dry eye disease within a month of regular use, applied about four times a day, but signs generally take several months to improve. Not all patients with dry eye disease benefit from artificial tears, so if there is no benefit over a month, alternative management should be considered. Combination formulations are more effective than single active ingredient artificial tears. Artificial tears containing polyethylene glycol are more effective than those containing carboxymethylcellulose/carmellose sodium and hydroxypropyl methylcellulose. Those classified as having evaporative dry eye disease, benefit from artificial tears with liposomes, especially of higher concentration. The data available is limited by the definition of dry eye disease applied in published studies being variable, as well as the disease severity examined and compliance with artificial tears being rarely quantified.

10.
Cont Lens Anterior Eye ; 45(2): 101514, 2022 04.
Article in English | MEDLINE | ID: mdl-34511307

ABSTRACT

PURPOSE: To evaluate the efficacy of multifocal soft contact lenses to reduce asthenopic symptoms in myopes with accommodative lag. METHODS: Twenty-four myopic participants, aged 18-35 years, with mean spherical equivalent (MSE) of ≤ -0.75D, were recruited in a randomised, double-blind crossover study. All participants were existing contact lens wearer with near orthophoria or esophoria, presenting with subjective asthenopic symptoms at baseline [Convergence Insufficiency Symptom Survey (CISS) score ≥ 21] and a lag of accommodation ≥ +0.75 D. All participants were initially fitted with single vision contact lenses for a one month period. Participants were then randomly assigned 1:1 to wear low add or high add multifocal soft contact lenses for a further month. After this period, the groups were reversed. Data were collected at baseline and following one month's wear of each lens. Change in CISS score was evaluated as the primary outcome measure, while secondary outcome measures were changes in accommodative lag and heterophoria status. RESULTS: Baseline CISS score was (mean ± SD) 25.04 ± 4.58. Post-intervention scores were as follows: single vision: 24.46 ± 4.59, low add: 12.17 ± 6.89, high add: 13.71 ± 7.23. Both low add and high add multifocal soft contact lens wear was associated with an improvement in CISS score compared to baseline CISS and single vision (all p < 0.01). No significant difference was found between the CISS score for the baseline CISS and single vision (p = 1.00). No significant difference was found in lag of accommodation between lens conditions (all p > 0.05), however, there was an exophoric shift in near heterophoria between single vision and both multifocal contact lenses (low add: (mean difference 1.33 Δ, p = 0.02; high add: mean difference 1.23 Δ, p = 0.02) but not between habitual spectacle or any other modality (all p > 0.05). CONCLUSIONS: The use of multifocal soft contact lenses for a one-month period was associated with reduced severity of asthenopic symptoms in pre-presbyopic myopes with accommodative lag. Whilst improvement of symptoms does not appear to be mediated by a significant reduction in accommodative lag, changes in heterophoria may play a role in reducing asthenopic symptoms.


Subject(s)
Contact Lenses, Hydrophilic , Myopia , Accommodation, Ocular , Cross-Over Studies , Humans , Myopia/therapy , Refraction, Ocular
11.
Ophthalmic Physiol Opt ; 41(6): 1165-1175, 2021 11.
Article in English | MEDLINE | ID: mdl-34545597

ABSTRACT

PURPOSE: To investigate the attitudes and understanding of optometrists in the UK and Ireland towards Digital Eye Strain (DES), and to examine related practice patterns. METHODS: An anonymous online questionnaire was developed, covering attitude and understanding of DES, examination of patients who may be experiencing DES and approaches to management options. The questionnaire was promoted to UK and Ireland optometrists via professional bodies and local and area optometric committees. RESULTS: 406 responses were included in the analysis. Most respondents agreed that DES was an important concern for optometrists (88.9%). 91.4% reported they felt confident in discussing possible symptoms of DES and management options; this was weakly and negatively associated with number of years qualified (rs  = -0.198, p ≤ 0.001). Estimations of the proportion of patients affected by DES were lower than reports in the literature (median 25%, IQR 10%-50%). Most respondents always (60.6%) or frequently (21.9%) inquired about device usage in routine case history taking, and also asked follow-up questions, although 29.3% only asked about the presence of symptoms half the time or less. Advising on regular breaks (84.0%), lubricants (55.7%) and environment/set up (69.2%) were felt to be extremely or very important by most respondents. Advising on specialist spectacle lenses, specifically blue filtering designs, was considered extremely or very important by 34.2% and 15.2%, respectively. CONCLUSION: Given the agreement that DES is a significant issue causing frequent and persistent symptoms, and practitioners reported high levels of confidence in discussing DES, patients can expect to receive advice on symptoms and management from their optometrist. Simple management strategies were felt to be most important to advise on, with more uncertainty linked to specialist spectacle lenses.


Subject(s)
Optometrists , Optometry , Health Knowledge, Attitudes, Practice , Humans , Ireland , United Kingdom
12.
Vision (Basel) ; 3(3)2019 Jun 28.
Article in English | MEDLINE | ID: mdl-31735835

ABSTRACT

The key determinants of the range of clear focus in pre-presbyopes and their relative contributions to the difference between subjective range of focus and objective accommodation assessments have not been previously quantified. Fifty participants (aged 33.0 ± 6.4 years) underwent simultaneous monocular subjective (visual acuity measured with an electronic test-chart) and objective (dynamic accommodation measured with an Aston open-field aberrometer) defocus curve testing for lenses between +2.00 to -10.00 DS in +0.50 DS steps in a randomized order. Pupil diameter and ocular aberrations (converted to visual metrics normalized for pupil size) at each level of blur were measured. The difference between objective range over which the power of the crystalline lens changes and the subjective range of clear focus was quantified and the results modelled using pupil size, refractive error, tolerance to blur, and ocular aberrations. The subjective range of clear focus was principally accounted for by age (46.4%) and pupil size (19.3%). The objectively assessed accommodative range was also principally accounted for by age (27.6%) and pupil size (15.4%). Over one-quarter (26.0%) of the difference between objective accommodation and subjective range of clear focus was accounted for by age (14.0%) and spherical aberration at maximum accommodation (12.0%). There was no significant change in the objective accommodative response (F = 1.426, p = 0.229) or pupil size (F = 0.799, p = 0.554) of participants for levels of defocus above their amplitude of accommodation. Pre-presbyopes benefit from an increased subjective range of clear vision beyond their objective accommodation due in part to neural factors, resulting in a measured depth-of-focus of, on average, 1.0 D.

13.
J Refract Surg ; 35(1): 48-53, 2019 Jan 01.
Article in English | MEDLINE | ID: mdl-30633787

ABSTRACT

PURPOSE: To determine the rotational stability of the Rayner 600S intraocular lens (IOL) (Rayner, Worthing, United Kingdom) using objective image analysis techniques. METHODS: A total of 66 patients (mean age: 69.92 ± 8.45 years) with healthy eyes presenting for routine cataract surgery were implanted monocularly with the 600S IOL and followed up over 90 to 180 days postoperatively. Images of the IOL were captured through a maximally dilated pupil (tropicamide 1.0%, phenylephrine 2.5%) immediately after surgery and after 1 to 3 days, 30 days, and 90 to 180 days using a digital slit-lamp biomicro-scope. The orientation of the IOL markings were image analyzed compared to conjunctival blood vessel landmarks visible across all time points to correct for head and rotation. Centration was assessed by drawing ovals to circumscribe the IOL, pupil, and limbus to compare the centers (0.01 mm per-pixel resolution). RESULTS: Absolute values for rotation postoperatively were 1.60° ± 1.13° at 1 to 3 days, 1.58° ± 1.36° at 30 days, and 1.83° ± 1.44° at 90 to 180 days. No lens rotated more than 5°. The average centration relative to the limbus was -0.04 ± 0.25 mm horizontally and 0.04 ± 0.26 mm vertically at 1 to 3 days, 0.00 ± 0.38 mm vertically and 0.01 ± 0.28 mm horizontally at 30 days, and 0.08 ± 0.37 mm vertically and 0.07 ± 0.47 mm horizontally at 90 to 180 days. CONCLUSIONS: The Rayner 600S IOL showed exceptional rotational stability and centration after implantation, meeting the U.S. Food and Drug Administration prescribed American National Standards Institute standards for toric IOLs. [J Refract Surg. 2019;35(1):48-53.].


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification/methods , Prosthesis Design , Prosthesis Failure , Rotation , Aged , Astigmatism/physiopathology , Female , Humans , Male , Middle Aged , Prospective Studies , Pseudophakia/physiopathology , Refraction, Ocular/physiology , Visual Acuity/physiology
14.
BMJ Open Ophthalmol ; 3(1): e000146, 2018.
Article in English | MEDLINE | ID: mdl-29963645

ABSTRACT

Digital device usage has increased substantially in recent years across all age groups, so that extensive daily use for both social and professional purposes is now normal. Digital eye strain (DES), also known as computer vision syndrome, encompasses a range of ocular and visual symptoms, and estimates suggest its prevalence may be 50% or more among computer users. Symptoms fall into two main categories: those linked to accommodative or binocular vision stress, and external symptoms linked to dry eye. Although symptoms are typically transient, they may be frequent and persistent, and have an economic impact when vocational computer users are affected. DES may be identified and measured using one of several available questionnaires, or objective evaluations of parameters such as critical flicker-fusion frequency, blink rate and completeness, accommodative function and pupil characteristics may be used to provide indices of visual fatigue. Correlations between objective and subjective measures are not always apparent. A range of management approaches exist for DES including correction of refractive error and/or presbyopia, management of dry eye, incorporating regular screen breaks and consideration of vergence and accommodative problems. Recently, several authors have explored the putative role of blue light-filtering spectacle lenses on treating DES, with mixed results. Given the high prevalence of DES and near-universal use of digital devices, it is essential that eye care practitioners are able to provide advice and management options based on quality research evidence.

15.
J. optom. (Internet) ; 11(1): 49-56, ene.-mar. 2018. tab, graf
Article in English | IBECS | ID: ibc-169369

ABSTRACT

Purpose: To investigate non-cycloplegic changes in refractive error prior to the onset of presbyopia. Methods: The Aston Longitudinal Assessment of Presbyopia (ALAP) study is a prospective 2.5 year longitudinal study, measuring objective refractive error using a binocular open-field WAM-5500 autorefractor at 6-month intervals in participants aged between 33 and 45 years. Results: From the 58 participants recruited, 51 participants (88%) completed the final visit. At baseline, 21 participants were myopic (MSE -3.25 ± 2.28 DS; baseline age 38.6 ± 3.1 years) and 30 were emmetropic (MSE -0.17 ± 0.32 DS; baseline age 39.0 ± 2.9 years). After 2.5 years, 10% of the myopic group experienced a hypermetropic shift (≥0.50 D), 5% a myopic shift (≥0.50 D) and 85% had no significant change in refraction (<0.50 D). From the emmetropic group, 10% experienced a hypermetropic shift (≥0.50 D), 3% a myopic shift (≥0.50 D) and 87% had no significant change in refraction (<0.50 D). In terms of astigmatism vectors, other than J45 (p < 0.001), all measures remained invariant over the study period. Conclusion: The incidence of a myopic shift in refraction during incipient presbyopia does not appear to be as large as previously indicated by retrospective research. The changes in axis indicate ocular astigmatism tends towards the against-the-rule direction with age. The structural origin(s) of the reported myopic shift in refraction during incipient presbyopia warrants further investigation (AU)


Objetivo: Investigar los cambios en el error refractivo sin cicloplégico con anterioridad a la aparición de la presbicia. Métodos: El estudio de la evaluación longitudinal de la presbicia de Aston (ALAP) es un estudio longitudinal prospectivo de 2,5 años que mide el error refractivo objetivo utilizando un autorrefractor binocular de campo abierto WAM-5500 a intervalos de 6 meses, en participantes con edades comprendidas entre 33 y 45 años. Resultados: De los 58 participantes estudiados, 51 de ellos (88%) completaron la visita final. Al inicio, 21 participantes eran miopes (MSE -3,25 ± 2,28 DS; edad basal: 38,6 ± 3,1 años) y 30 eran emétropes (MSE -0,17 ± 0,32 DS; edad basal: 39 ± 2,9 años). Transcurridos 2,5 años, el 10% del grupo de participantes miopes experimentó un cambio hipermetrópico (≥0,5 D), el 5% un cambio miópico (≥0,5 D), y el 85% no experimentó cambio refractivo significativo alguno (<0,5 D). En el grupo emétrope, el 10% experimentó un cambio hipermetrópico (≥0,5 D), el 3% un cambio miópico (≥0,5 D), y el 87% no experimentó cambio refractivo significativo alguno (<0,5 D). En términos de vectores astigmáticos, todas las mediciones permanecieron invariables durante el periodo de estudio excepto J45 (p<0,001). Conclusión: La incidencia del cambio miópico en la refracción durante la presbicia incipiente no parece ser tan grande como anteriormente indicado en investigaciones retrospectivas. Los cambios en los ejes indican que el astigmatismo ocular tiende hacia la dirección contra la norma con la edad. El(los) origen(es) estructural(es) del cambio miópico reportado en la refracción durante la presbicia incipiente justifica la investigación futura (AU)


Subject(s)
Humans , Adult , Presbyopia/epidemiology , Presbyopia/prevention & control , Myopia/epidemiology , Accommodation, Ocular/physiology , Emmetropia/physiology , Longitudinal Studies , Prospective Studies , Vision, Monocular/physiology , Vision, Binocular/physiology , Surveys and Questionnaires , 28599 , Cross-Sectional Studies/methods
16.
J Optom ; 11(1): 49-56, 2018.
Article in English | MEDLINE | ID: mdl-28599911

ABSTRACT

PURPOSE: To investigate non-cycloplegic changes in refractive error prior to the onset of presbyopia. METHODS: The Aston Longitudinal Assessment of Presbyopia (ALAP) study is a prospective 2.5 year longitudinal study, measuring objective refractive error using a binocular open-field WAM-5500 autorefractor at 6-month intervals in participants aged between 33 and 45 years. RESULTS: From the 58 participants recruited, 51 participants (88%) completed the final visit. At baseline, 21 participants were myopic (MSE -3.25±2.28 DS; baseline age 38.6±3.1 years) and 30 were emmetropic (MSE -0.17±0.32 DS; baseline age 39.0±2.9 years). After 2.5 years, 10% of the myopic group experienced a hypermetropic shift (≥0.50 D), 5% a myopic shift (≥0.50 D) and 85% had no significant change in refraction (<0.50 D). From the emmetropic group, 10% experienced a hypermetropic shift (≥0.50 D), 3% a myopic shift (≥0.50 D) and 87% had no significant change in refraction (<0.50 D). In terms of astigmatism vectors, other than J45 (p<0.001), all measures remained invariant over the study period. CONCLUSION: The incidence of a myopic shift in refraction during incipient presbyopia does not appear to be as large as previously indicated by retrospective research. The changes in axis indicate ocular astigmatism tends towards the against-the-rule direction with age. The structural origin(s) of the reported myopic shift in refraction during incipient presbyopia warrants further investigation.


Subject(s)
Presbyopia/physiopathology , Refraction, Ocular/physiology , Vision Tests/methods , Adult , Disease Progression , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Time Factors
17.
Clin Exp Optom ; 100(6): 676-682, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28294406

ABSTRACT

BACKGROUND: The aim was to profile transient accommodative axial length changes from early adulthood to advanced presbyopia and to determine whether any differences exist between the responses of myopic and emmetropic individuals. METHODS: Ocular biometry was measured by the LenStar biometer (Haag-Streit, Switzerland) in response to zero, 3.00 and 4.50 D accommodative stimuli in 35 emmetropes and 37 myopes, aged 18 to 60 years. All results were corrected to reduce errors arising from the increase in crystalline lens thickness with accommodation. Accommodative responses were measured sequentially by the WAM 5500 Auto Ref/Keratometer (Grand Seiko, Hiroshima, Japan). RESULTS: Axial length increased significantly with accommodation (p < 0.001), with a mean corrected increase in axial length of 2 ± 18 µm and 8 ± 16 µm observed at 3.00 and 4.50 D, respectively. The magnitude of accommodative change in axial length was not dependent on refractive error classification (p = 0.959); however, a significant reduction in the magnitude and variance of axial length change was evident after 43 to 44 years of age (p < 0.002). CONCLUSION: The negative association between transient increase in axial length and age, in combination with reduced variance of data after age 43 to 44 years, is consistent with a significant increase in posterior ocular rigidity, which may be influential in the development of presbyopia.


Subject(s)
Accommodation, Ocular/physiology , Aging/physiology , Axial Length, Eye/physiology , Myopia/physiopathology , Presbyopia/physiopathology , Adolescent , Adult , Biometry , Emmetropia/physiology , Female , Humans , Male , Middle Aged , Young Adult
18.
Ophthalmic Physiol Opt ; 36(1): 33-42, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26432063

ABSTRACT

PURPOSE: To profile accommodative biometric changes longitudinally and to determine the influence of age-related ocular structural changes on the accommodative response prior to the onset of presbyopia. METHODS: Twenty participants (aged 34-41 years) were reviewed at six-monthly intervals over two and a half years. At each visit, ocular biometry was measured with the LenStar biometer (www.Haag-Streit.com) in response to 0.00, 3.00 and 4.50 D stimuli. Accommodative responses were measured by the WAM 5500 Auto Ref/Keratometer (www.grandseiko.com). RESULTS: During accommodation, anterior chamber depth reduced (F = 29, p < 0.001), whereas crystalline lens thickness (F = 39, p < 0.001) and axial length (F = 5.4, p = 0.009) increased. The accommodative response (F = 5.5, p = 0.001) and the change in anterior chamber depth (F = 3.1, p = 0.039), crystalline lens thickness (F = 3.0, p = 0.042) and axial length (F = 2.5, p = 0.038) in response to the 4.50 D accommodative target reduced after 2.5 years. However, the change in anterior chamber depth (F = 2.2, p = 0.097), crystalline lens thickness (F = 1.7, p = 0.18) and axial length (F = 1.0, p = 0.40) per dioptre of accommodation exerted remained invariant after 2.5 years. The increase in disaccommodated crystalline lens thickness with age was not significantly associated with the reduction in accommodative response (R = 0.32, p = 0.17). CONCLUSION: Despite significant age-related structural changes in disaccommodated biometry, the change in biometry per dioptre of accommodation exerted remained invariant with age. The present study supports the Helmholtz theory of accommodation and suggests an increase in lenticular stiffness is primarily responsible for the onset of presbyopia.


Subject(s)
Accommodation, Ocular/physiology , Lens, Crystalline/physiopathology , Presbyopia/physiopathology , Adult , Aging/physiology , Analysis of Variance , Anterior Chamber/pathology , Axial Length, Eye/pathology , Biometry/methods , Female , Humans , Longitudinal Studies , Male
19.
Cont Lens Anterior Eye ; 38(6): 402-8, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26072268

ABSTRACT

PURPOSE: To describe and validate bespoke software designed to extract morphometric data from ciliary muscle Visante Anterior Segment Optical Coherence Tomography (AS-OCT) images. METHOD: Initially, to ensure the software was capable of appropriately applying tiered refractive index corrections and accurately measuring orthogonal and oblique parameters, 5 sets of custom-made rigid gas-permeable lenses aligned to simulate the sclera and ciliary muscle were imaged by the Visante AS-OCT and were analysed by the software. Human temporal ciliary muscle data from 50 participants extracted via the internal Visante AS-OCT caliper method and the software were compared. The repeatability of the software was also investigated by imaging the temporal ciliary muscle of 10 participants on 2 occasions. RESULTS: The mean difference between the software and the absolute thickness measurements of the rigid gas-permeable lenses were not statistically significantly different from 0 (t=-1.458, p=0.151). Good correspondence was observed between human ciliary muscle measurements obtained by the software and the internal Visante AS-OCT calipers (maximum thickness t=-0.864, p=0.392, total length t=0.860, p=0.394). The software extracted highly repeatable ciliary muscle measurements (variability ≤6% of mean value). CONCLUSION: The bespoke software is capable of extracting accurate and repeatable ciliary muscle measurements and is suitable for analysing large data sets.


Subject(s)
Ciliary Body/anatomy & histology , Image Processing, Computer-Assisted , Muscle, Smooth/anatomy & histology , Tomography, Optical Coherence , Adult , Female , Humans , Male , Reproducibility of Results , Software
20.
Cont Lens Anterior Eye ; 37(3): 191-5, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24275625

ABSTRACT

PURPOSE: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. SETTING: University vision clinic. METHODS: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. RESULTS: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F=70.341; p<0.001). Comparatively better acuities were observed around 180°, as anticipated (F=3.775; p=0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F=2.190, p=0.129) or high cylinder (F=0.491, p=0.617) or in the adapted astigmats (F=0.120, p=0.887). CONCLUSION: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect.


Subject(s)
Astigmatism/diagnosis , Astigmatism/etiology , Lens Implantation, Intraocular/adverse effects , Lenses, Intraocular/adverse effects , Patient Satisfaction , Prosthesis Fitting/adverse effects , Adult , Astigmatism/prevention & control , Female , Humans , Male , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...