Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Can J Cardiol ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38964464

ABSTRACT

Current practice guidelines recommend antibiotic prophylaxis in patients with high-risk congenital heart conditions, including those with Prosthetic heart valves and prosthetic material, including annuloplasty rings or clips undergoing invasive dental procedures. However, there is limited clinical data on the burden of infective endocarditis (IE) following Mitral TEER. This study investigated temporal trends of very early IE immediately after TEER using National Inpatient Sample from 2016 - 2020. It showed that the rate of very early TEER-related IE was relatively low over the five years of analysis and that there was a downward trend of very early IE after TEER.

2.
Am J Cardiovasc Dis ; 14(1): 9-20, 2024.
Article in English | MEDLINE | ID: mdl-38495406

ABSTRACT

BACKGROUND: Data on the impact of chronic thrombocytopenia (CT) on outcomes following chronic total occlusion (CTO) percutaneous coronary interventions (PCI) is limited. Most studies are case reports and focused on postprocedural thrombocytopenia. The purpose of this present study is to assess the impact of CT (> one year) on health resource utilization (HRU), in-hospital outcomes, and cost following CTO PCI. METHODS: We used discharge data from the 2016-2018 National Inpatient Sample and propensity score-weighted approach to examine the association between CT and HRU among patients undergoing CTO PCI. HRU was measured as a binary indicator defined as a length of stay greater than seven days and/or discharge to a non-home setting. The cost was measured as total charges standardized to 2018 dollars. Both outcomes were assessed using generalized linear models adjusted for survey year, and baseline characteristics. RESULTS: Relative to its absence, the presence of CT following CTO PCI was associated with a 4.8% increased probability of high HRU (Population Average Treatment Effect (PATE) estimate = 0.048; 95% Confidence Interval (CI) = 0.041-0.055; P<0.001) and approximately $18,000 more in total hospital charges (PATE estimate = +$18,297.98; 95% CI = $15,101.33-$21,494.63, P<0.001). CONCLUSION: Among chronic total occlusion patients undergoing percutaneous coronary intervention, those with chronic thrombocytopenia had higher resource use, including total hospital charges, and worse in-hospital outcomes when compared with those without chronic thrombocytopenia.

3.
Curr Probl Cardiol ; 49(1 Pt A): 102053, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37640173

ABSTRACT

The use of percutaneous mechanical circulatory support (MCS) devices, including Impella and Intra-aortic balloon pump (IABP), in patients with cardiogenic shock has increased in recent times. We aimed to evaluate the impact of the choice of an MCS device on healthcare resource utilization. We queried the National Inpatient Sample registry between October 2016 and December 2018 to identify adults admitted for acute coronary syndrome-related cardiogenic shock and who received percutaneous coronary intervention (PCI). The study population was segregated into Impella and IABP groups using ICD 10 diagnosis codes. The primary endpoint was high healthcare resource utilization (HRU), while secondary outcomes included periprocedural complications. Propensity scoring matching was used to determine which patients in the Impella cohort had similar health to IABP patients. During the study period, 439,610 patients were admitted who received hemodynamic support using, Impella or IABP on account of acute coronary syndrome complicated by cardiogenic shock (CS). The median age (years) of the Impella cohort and IABP cohorts were similar (64.1 vs 65.1, P = 0.08). Gender distribution of the Impella CS patients was like IABP patients with female majorities in both groups, (71.9% vs 67.9%, P = 0.05). Impella CS patients had a higher representation of those with hypertension (P = 0.002), smoking (P = 0.040), obesity (P = 0.034), diabetes mellitus (P = 0.009), CHF (P = 0.030), COPD (P = 0.034), chronic liver disease (P = 0.028), and chronic kidney disease (P = 0.031). 1:1 Propensity score matching identified 2620 Impella patients' comparable severity index with the IABP patients. Patients with hemodynamic support using Impella had higher healthcare resource utilization, (HRU), the surrogate of length of stay (LOS) ≥7 or nonhome disposition at discharge, when compared with those with IABP (57.41% vs 42.76%, P < 0.0001). Impella CS patients had higher in-hospital mortality as compared to the IABP patients (55.45% vs 45.86%, P < 0.0001). Impella CS patients developed more periprocedural complications, including vascular injury (4.8% vs 1.4%, P < 0.0001), acute kidney injury (58.36% vs 41.64%, P < 0.0001), end-stage renal disease requiring dialysis (8.75% vs 1.25%, P = 0.002) when compared to the IABP patients. Among patients with ACS undergoing PCI and receiving MCS devices, those receiving Impella demonstrated higher healthcare resource utilization, higher LOS ≥7 days, and more nonhome disposition at discharge compared to patients receiving IABP. Further investigation is warranted to elucidate factors associated with these findings.


Subject(s)
Acute Coronary Syndrome , Heart-Assist Devices , Percutaneous Coronary Intervention , Humans , Female , Shock, Cardiogenic/epidemiology , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Percutaneous Coronary Intervention/adverse effects , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/complications , Inpatients , Heart-Assist Devices/adverse effects , Delivery of Health Care , Treatment Outcome
4.
Clin Case Rep ; 11(9): e7824, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37655130

ABSTRACT

Key Clinical Message: In this case report, the utility of MDCT in elucidating the pathophysiology and etiology of prosthetic aortic valve dysfunction allowed us to distinguish thrombosis from pannus as an etiology of prosthetic valve dysfunction. MDCT also guided the success of therapy. Abstract: The diagnosis and management of prosthetic aortic valve thrombosis (PAVT) is challenging. The accurate diagnosis of this entity and its prompt management is vital to improving the prognosis of PAVT patients. Multidetector CT plays a central role in this effort. We present a case of PAVT in which the use of MDCT was useful in guiding management.

5.
Cardiovasc Revasc Med ; 50: 13-18, 2023 05.
Article in English | MEDLINE | ID: mdl-36642556

ABSTRACT

BACKGROUND: This study sought to investigate health and healthcare disparities in the management of severe mitral regurgitation with transcatheter edge-to-edge repair using MitraClip and how racial differences impact resource utilization and costs. METHODS: We retrospectively analyzed the National Inpatient Sample (NIS) for patients who underwent Transcatheter Edge-to-Edge Repair (TEER) using MitraClip between 2016 and 2018. The patients were stratified into four racial cohorts and study outcomes included high resource utilization (HRU), periprocedural complications, and total procedural costs. High resource utilization (HRU) was defined as length of stay (LOS) ≥7 days or a nonhome disposition at discharge. Multivariate logistic regression models were utilized to determine independent predictors of HRU. RESULTS: 17,100 weighted TEER patients were segregated by race: Caucasian (n = 13,270), others (n = 1510), African Americans, AA (n = 1245) and Hispanics (n = 1075). More African Americans and Hispanics had TEER at Urban facilities (P < 0.001), which were teaching hospitals as well (P < 0.001) but were less likely to be covered by public insurance options -Medicare or Medicaid (P < 0.001). More AA (52.2 %) and Hispanics (27.6 %) were likely to be in the lowest median annual income quartile versus Caucasians (19.2 %) (P = 0.003). AA and Hispanics had higher resource utilization (HRU), prolonged length of stay, nonhome disposition at discharge, higher procedural costs and periprocedural complications versus Caucasians. The logistic regression model revealed acute kidney injury (AKI) and actual procedural costs as independent predictors of HRU in both African American and Hispanic groups. CONCLUSION: Significant Health and healthcare disparities do exist among underrepresented, racial minority patients undergoing transcatheter edge-to-edge repair in the US. These disparities were associated with higher resource utilization and actual costs in patients with mitral regurgitation treated with TEER.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Aged , United States , Mitral Valve Insufficiency/surgery , Retrospective Studies , Medicare , Healthcare Disparities , Treatment Outcome , White
6.
Clin Case Rep ; 10(12): e6717, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36514473

ABSTRACT

Takotsubo cardiomyopathy (TC), an acute cardiac event is often associated with acute emotional stress, usually in the setting of cardiovascular risk factors. This case report attempts to review one of the triggers of TC beer potomania-induce hyponatremia with imaging findings that shows the link between severe hyponatremia and TC.

7.
Anesth Essays Res ; 16(1): 1-6, 2022.
Article in English | MEDLINE | ID: mdl-36249135

ABSTRACT

Background: Choosing the correct Endotracheal tube (ETT) size is important in paediatric patients because an inappropriately large and small sized tube has its own disadvantages and chances of re-intubation with different size tube is high. The currently available modalities do not reflect the actual tracheal diameter for selection of endotracheal tube. Ultrasonography (USG) guided evaluation of transverse diameter at subglottic region may be helpful to estimate the proper size of ETT. We tested the hypothesis that Ultrasound guided subglottic diameter better predicts optimal ETT size than existing methods. Aims: To predict the appropriate size of ETT in pediatric patients to avoid multiple attempts of intubation and airway edema using simple noninvasive USG-guided methods. Settings and Design: Design: Prospective study. Settings: Tertiary care hospital. Materials and Methods: Institutional ethical committee clearance no. BMCRI/PS/138/2020-21 was taken. Laryngoscopy and endotracheal intubation were done in 27 pediatric patients of age 2-15 years using a predetermined-sized ETT, estimated by ultrasonography. ETT size was considered optimal when the cuff leak test was negative. If there was resistance to ETT passage into the trachea, the tube was exchanged with one that was 0.5 mm smaller. If the cuff leak test was positive, then the ETT was exchanged for one with the 0.5-mm larger tube. The comparison was done between the size of ETT calculated by USG-guided subglottic diameter, age, height-related formulas, and clinical methods to look for accuracy of prediction for proper ETT size after cuff leak test. Statistical Analysis: The data collected were entered into Microsoft Excel and analyzed using SPSS version 22. IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp. Appropriate parametric and nonparametric tests were applied wherever necessary. Categorical data: Represented in the form of frequencies and proportions. Continuous data: Represented as mean and standard deviation. Paired sample test: Test to identify the mean difference between two quantitative variables. Kappa statistics: To measure the level of agreement. Results: A total of 27 children of age between 2 and 15 years were selected, out of which 15 were male and 12 were female. The accuracy of predicting appropriate ETT size is greater in ultrasound-guided subglottic diameter when compared to conventional clinical assessment and age- and height-related formula and almost the same accuracy as the clinical method. Conclusion: Ultrasound-guided subglottic diameter is an easy, effective, and noninvasive way of predicting accurate ETT size in the pediatric population.

8.
Cardiovasc Revasc Med ; 39: 101-105, 2022 06.
Article in English | MEDLINE | ID: mdl-34610901

ABSTRACT

OBJECTIVE: The MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published studies, there is limited safety data for its use in clinical practice, hence, we designed this study using data obtained from a safety nationwide database to demonstrate the safety profile of MitraClip. METHODS: The first two of the five authors independently queried all reported adverse events from the United State Food and Drug Administration [FDA] Manufacturer and User Facility Device Experience [MAUDE] registry from January 2014 to December 2020. The primary end point was trend in reported fatal events obtained from this database. The secondary end points included the causes of reported nonfatal reports from the MAUDE registry. The trend of reported fatal events was assessed using the Cochran Armitage trend test over the period of the study. RESULTS: During the study period, subjects included 3370 patients whose MitraClip-associated adverse events were reported and captured by MAUDE registry. Of these, 211 were fatal and 3159 nonfatal events. Fatal event reports resulted deaths and reported nonfatal events were from injuries and device system malfunction. This study demonstrated an initial upward trend from 2014 to 2015 then a subsequent statistically significant downward trend in reported fatal events from 2015 to 2020 (Cochran-Armitage test P = 0.039). The peak proportion of reported fatal events occurred in 2015, (n = 44; representing 1.25% of reported adverse events) and lowest proportion of reported fatal events took place in 2020 (n = 19; representing 0.56% of reported adverse events). The most reported nonfatal events were from malfunctioning of MitraClip system (n = 1170; representing 37% of reported nonfatal events), new unremarkable repolarization abnormalities on periprocedural EKG (n = 864; representing 27% of reported nonfatal events), leaflet rupture (n = 651; representing 21% of reported nonfatal events), and cardiogenic shock (n = 170; representing 5% of reported nonfatal events). CONCLUSIONS: This analysis of the MAUDE Registry indicated, especially within the confines of this study's limitations and poor data quality of information, an apparent downward trend of reported fatal events over the study period. Even though conclusive attributions cannot be made regarding this important finding, perhaps, this points to early evidence of a potential institutional or operator learning curve with this device. However, in view of the inferior quality of the data accrued from the MAUDE Registry, more high-precision studies are needed to better understand these changes, as the utility of MitraClip, becomes more established in clinical practice.


Subject(s)
United States Food and Drug Administration , Databases, Factual , Humans , Registries , United States
9.
Ann R Coll Surg Engl ; 104(3): 158-164, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34730401

ABSTRACT

INTRODUCTION: Heller myotomy (HM) remains the gold standard procedure for achalasia. The addition of different types of fundoplication to HM has been debated in several studies. Given the contradictory reports, this meta-analysis was undertaken to compare different outcomes after HM and HM with fundoplication (HMF). METHODS: An electronic search was performed among five major databases (PubMed, Ovid, Scopus, Cochrane Library, Google Scholar) from inception to October 2019, identifying all randomised and non-randomised studies comparing HM with HMF. Two authors searched electronic databases using the keywords 'achalasia' AND 'dysphagia' AND 'gastroesophageal reflux' and all data were pooled for random-effects meta-analysis. The primary and secondary outcomes were gastroesophageal reflux and dysphagia, respectively. RESULTS: A total of six studies were included and involved 576 patients comparing HM and HMF. There was no statistically significant difference between gastroesophageal reflux in the HM vs HMF group (21.3% vs 22.9%, RR 1.32, 95% CI 0.60-2.88, p = 0.49). There was a slightly higher incidence of dysphagia observed in HM vs HMF (14.8% vs 10.8%, RR 1.54, 95% CI 0.98-2.41, p = 0.06). CONCLUSIONS: There was no statistically significant difference in long-term outcomes between a group of patients undergoing HM and a group who underwent HM with fundoplication.


Subject(s)
Esophageal Achalasia , Fundoplication , Heller Myotomy , Aged , Deglutition Disorders/epidemiology , Esophageal Achalasia/epidemiology , Esophageal Achalasia/surgery , Female , Fundoplication/adverse effects , Fundoplication/statistics & numerical data , Heller Myotomy/adverse effects , Heller Myotomy/statistics & numerical data , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Treatment Outcome
10.
Cardiol Clin ; 35(2): 185-196, 2017 May.
Article in English | MEDLINE | ID: mdl-28411893

ABSTRACT

Genomic insights and analyses of Mendelian hypertension (HTN) syndromes and Genome-Wide Association study (GWAS) on essential hypertension have contributed to the depth of understanding of the genetics origins of hypertension. Mendelian syndromes are important for the field, since such knowledge leads to specific insights about disease pathogenesis and the potential for precision medicine. The clinical impact of findings of on essential hypertension is continuously evolving, and the insights accrued will refine efforts to combat the societal impact of hypertension. Comprehensive identification of all genomic variants of hypertension, along with their individual associated mechanisms, is paving the way forward in the era of personalized medicine. The overriding challenge for care providers is to reduce health inequities through improved compliance and, perhaps, new paradigms for implementation science that incorporate genomic medicine.


Subject(s)
Genome-Wide Association Study , Genomics/methods , Hypertension/genetics , Humans
11.
Arch Dis Child ; 93(4): 307-12, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18356383

ABSTRACT

OBJECTIVES: To compare clinical practice guideline (CPG) recommendations and reported physician management of acute paediatric asthma in the 11 largest paediatric emergency departments, all of which have CPGs, in Australia (n = 9) and New Zealand (n = 2). All 11 sites participate in the Paediatric Research in Emergency Departments International Collaborative (PREDICT) research network. METHODS: (a) A review of CPGs for acute childhood asthma from all PREDICT sites. (b) A standardised anonymous survey of senior emergency doctors at PREDICT sites investigating management of acute childhood asthma. RESULTS: CPGs for mild to moderate asthma were similar across sites and based on salbutamol delivery by metered dose inhaler with spacer and oral prednisolone. In severe to critical asthma, differences between sites were common and related to recommendations for: ipratropium use; metered-dose inhaler versus nebulised delivery of salbutamol in severe asthma; use of intravenous aminophylline, intravenous magnesium and dosing of intravenous salbutamol in critical asthma. The questionnaire (78 of 83 doctors responded) also revealed significant differences between doctors in the treatment of moderate to severe asthma. Ipratropium was used for moderate asthma by 42%. For severe to critical asthma, nebulised delivery of salbutamol was preferred by 79% of doctors over metered dose inhalers. For critical asthma, doctors reported using intravenous aminophylline in 45%, intravenous magnesium in 55%, and intravenous salbutamol in 87% of cases. Thirty-nine different dosing regimens for intravenous salbutamol were reported. CONCLUSIONS: CPG recommendations and reported physician practice for mild to moderate paediatric asthma management were broadly similar across PREDICT sites and consistent with national guidelines. Practice was highly variable for severe to critical asthma and probably reflects limitations of available evidence. Areas of controversy, in particular the comparative efficacy of intravenous bronchodilators, would benefit from multi-centre trials. Collaborative development of CPGs should be considered.


Subject(s)
Anti-Asthmatic Agents/administration & dosage , Asthma/drug therapy , Practice Patterns, Physicians'/statistics & numerical data , Acute Disease , Albuterol/administration & dosage , Anti-Inflammatory Agents/administration & dosage , Australia , Child , Drug Therapy, Combination , Female , Guideline Adherence/statistics & numerical data , Health Care Surveys , Humans , Male , Metered Dose Inhalers , New Zealand , Practice Guidelines as Topic , Prednisolone/administration & dosage , Severity of Illness Index
12.
Psychopharmacology (Berl) ; 118(4): 425-36, 1995 Apr.
Article in English | MEDLINE | ID: mdl-7568629

ABSTRACT

The influence of alpha 2-adrenoceptor antagonists in animal models of anxiety is quite inconsistent, with results spanning the full range of effect from anxiogenesis to anxiolysis. In the present study, an ethological technique was used to examine the effects of yohimbine (0.5-4.0 mg/kg) on plus-maze behaviour in DBA/2 mice. Results indicated significant anxiolytic-like effects on standard spatiotemporal measures at 2.0-4.0 mg/kg, and on risk assessment measures across the entire dose range. Full-scale follow-up studies with T1 and BALB/c strains confirmed that this action of yohimbine in the murine plus-maze is not peculiar to DBA/2 mice. The more selective alpha 2-adrenoceptor antagonist, idazoxan (0.63-5.0 mg/kg), exerted much weaker behavioural effects in the maze while the alpha 2-adrenoceptor agonist, clonidine (0.01-0.1 mg/kg), produced a profile consistent with non-specific behavioural disruption. Data are discussed in relation to the possible involvement of 5-HT1A receptor mechanisms in the observed anxiolytic-like effects of yohimbine in the murine plus-maze.


Subject(s)
Anxiety/chemically induced , Behavior, Animal/drug effects , Receptors, Adrenergic, alpha-2/drug effects , Yohimbine/pharmacology , Animals , Clonidine/pharmacology , Dioxanes/pharmacology , Genotype , Idazoxan , Imidazoles/pharmacology , Mice , Mice, Inbred Strains
SELECTION OF CITATIONS
SEARCH DETAIL
...