1.
Expert Opin Drug Deliv ; 19(9): 1165-1176, 2022 09.
Article in English | MEDLINE | ID: mdl-36053114

ABSTRACT

OBJECTIVES: Many current subcutaneous (SC) biologic therapies may require >1 mL volume or have increased viscosity, necessitating new delivery system approaches. This study evaluated 2-mL large-volume autoinjector (LVAI) delivery performance across varying solution viscosities and design inputs to assess the design space and identify configurations that produce practical injection times. METHODS: Investigational LVAI delivery duration and volume, depot location, and tissue effects were examined in both air and in vivo models across various pre-filled syringe (PFS) cannula types (27 G Ultra-thin wall [UTW], 27 G special thin wall [STW], or 29 G thin-wall [TW]), drive spring forces (SFLOW or SFHIGH), and Newtonian solutions (2.3-50 centipoise [cP]). RESULTS: Within each design configuration, increasing PFS internal diameters and spring forces reduced delivery times, while increasing viscosity increased times. The 27 G UTW PFS/SFHIGH combination achieved shorter delivery times across all injection conditions, with 2 mL in vivo durations <15 seconds at ≤31 cP and routinely <20 seconds at 39 and 51 cP, with nominal and transitory tissue effects. CONCLUSION: PFS cannula and spring force combinations can be tailored to achieve various injection durations across viscosities, while UTW PFS enables faster rates to potentially better accommodate human factors during LVAI injection, especially at high viscosity.


Subject(s)
Syringes , Humans , Injections , Injections, Subcutaneous , Viscosity
2.
Drug Deliv ; 29(1): 43-51, 2022 Dec.
Article in English | MEDLINE | ID: mdl-34962225

ABSTRACT

A prototype reusable large-volume (2 mL) autoinjector (LVAI) was designed to compare injection performance of a novel 27 gauge ultra-thin wall (UTW) pre-filled syringe (PFS) cannula (8 mm external cannula length, 14.4 mm total needle length) against an existing 27 gauge special thin wall (STW) PFS cannula (12.7 mm external cannula length, 19 mm total needle length) across a range of injectate viscosities (2.3-30 cP) in a series of in vivo feasibility studies in swine. The UTW cannula had an approximately 30% greater cross-sectional lumen area than the STW cannula. The target exposed needle length was adjusted to ensure appropriate needle penetration depth and achieve injectate deposition in the subcutaneous (SC) tissue. Delivery time and volume, injection site leakage, injectate depot location, and local tissue effects were examined. The STW and UTW cannulae both provided effective SC delivery of contrast placebo solutions, and were able to accommodate injectate viscosity up to 30 cP without quantifiable leakage from the tissue and with minor tissue effects which resolved within 1-2 hours. Delivery times at each viscosity were significantly different between PFS types with the UTW PFS producing faster delivery times. In a histological substudy of the UTW cannula using injectate viscosities up to 50 cP, injection site reactions were rare and, when present, were of minimal severity. This series of studies demonstrates the feasibility of LVAI SC injection and informs autoinjector and PFS design considerations. Use of a UTW cannula may enable more rapid LVAI injections with minimal tissue effects, especially for higher viscosity formulations.


Subject(s)
Cannula , Equipment Design/methods , Injections, Subcutaneous/instrumentation , Viscosity , Animals , Female , Injection Site Reaction/prevention & control , Swine , Time Factors
3.
Int J Food Microbiol ; 198: 19-27, 2015 Apr 02.
Article in English | MEDLINE | ID: mdl-25590258

ABSTRACT

We describe a new approach for the real-time detection and identification of pathogens in food and environmental samples undergoing culture. Surface Enhanced Raman Scattering (SERS) nanoparticles are combined with a novel homogeneous immunoassay to allow sensitive detection of pathogens in complex samples such as stomached food without the need for wash steps or extensive sample preparation. SERS-labeled immunoassay reagents are present in the cultural enrichment vessel, and the signal is monitored real-time through the wall of the vessel while culture is ongoing. This continuous monitoring of pathogen load throughout the enrichment process enables rapid, hands-free detection of food pathogens. Furthermore, the integration of the food pathogen immunoassay directly into the enrichment vessel enables fully biocontained food safety testing, thereby significantly reducing the risk of contaminating the surrounding environment with enriched pathogens. Here, we present experimental results showing the detection of E. coli, Salmonella, or Listeria in several matrices (raw ground beef, raw ground poultry, chocolate milk, tuna salad, spinach, brie cheese, hot dogs, deli turkey, orange juice, cola, and swabs and sponges used to sample a stainless steel surface) using the SERS system and demonstrate the accuracy of the approach compared to plating results.


Subject(s)
Food Microbiology , Food Safety/methods , Immunoassay/standards , Nanotechnology , Animals , Dairy Products/microbiology , Escherichia coli/isolation & purification , Listeria/isolation & purification , Meat/microbiology , Salmonella/isolation & purification
4.
J Diabetes Sci Technol ; 6(6): 1286-95, 2012 Nov 01.
Article in English | MEDLINE | ID: mdl-23294773

ABSTRACT

BACKGROUND: Site-selective modification of proteins at two separate locations using two different reagents is highly desirable for biosensor applications employing fluorescence resonance energy transfer (FRET), but few strategies are available for such modification. To address this challenge, sequential selective modification of two cysteines in glucose/galactose binding protein (GGBP) was demonstrated using a technique we call "ligand protection." METHOD: In this technique, two cysteines were introduced in GGBP and one cysteine is rendered inaccessible by the presence of glucose, thus allowing sequential attachment of two different thiol-reactive reagents. The mutant E149C/A213C/L238S was first labeled at E149C in the presence of the ligand glucose. Following dialysis and removal of glucose, the protein was labeled with a second dye, either Texas Red (TR) C5 bromoacetamide or TR C2 maleimide, at the second site, A213C. RESULTS: Changes in glucose-dependent fluorescence were observed that were consistent with FRET between the nitrobenzoxadiazole and TR fluorophores. Comparison of models and spectroscopic properties of the C2 and C5 TR FRET constructs suggests the greater rigidity of the C2 linker provides more efficient FRET. CONCLUSIONS: The ligand protection strategy provides a simple method for labeling GGBP with two different fluorophores to construct FRET-based glucose sensors with glucose affinity within the human physiological glucose range (1-30 mM). This general strategy may also have broad utility for other protein-labeling applications.


Subject(s)
Biosensing Techniques/methods , Escherichia coli Proteins/chemistry , Fluorescence Resonance Energy Transfer/methods , Glucose/analysis , Monosaccharide Transport Proteins/chemistry , Protein Engineering/methods , Cysteine/chemistry , Models, Molecular , Mutagenesis, Site-Directed
5.
Protein Sci ; 16(11): 2350-9, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17905834

ABSTRACT

Periplasmic expression screening is a selection technique used to enrich high-affinity proteins in Escherichia coli. We report using this screening method to rapidly select a mutated D-glucose/D-galactose-binding protein (GGBP) having low affinity to glucose. Wild-type GGBP has an equilibrium dissociation constant of 0.2 microM and mediates the transport of glucose within the periplasm of E. coli. The protein undergoes a large conformational change on binding glucose and, when labeled with an environmentally sensitive fluorophore, GGBP can relay glucose concentrations, making it of potential interest as a biosensor for diabetics. This use necessitates altering the glucose affinity of GGBP, bringing it into the physiologically relevant range for monitoring glucose in humans (1.7-33 mM). To accomplish this a focused library was constructed using structure-based site-saturation mutagenesis to randomize amino acids in the binding pocket of GGBP at or near direct H-bonding sites and screening the library within the bacterial periplasm. After selection, equilibrium dissociation constants were confirmed by glucose titration and fluorescence monitoring of purified mutants labeled site-specifically at E149C with the fluorophore IANBD (N,N'-dimethyl-N-(iodoacetyl)-N'-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)ethylene-diamine). The screening identified a single mutation A213R that lowers GGBP glucose affinity 5000-fold to 1 mM. Computational modeling suggested the large decrease in affinity was accomplished by the arginine side chain perturbing H-bonding and increasing the entropic barrier to the closed conformation. Overall, these experiments demonstrate the ability of structure-based site-saturation mutagenesis and periplasmic expression screening to discover low-affinity GGBP mutants having potential utility for measuring glucose in humans.


Subject(s)
Biosensing Techniques , Calcium-Binding Proteins/chemistry , Escherichia coli/metabolism , Glucose/chemistry , Monosaccharide Transport Proteins/chemistry , Periplasmic Binding Proteins/chemistry , Protein Engineering/methods , Binding Sites , Calcium-Binding Proteins/metabolism , Cloning, Molecular , Fluorescent Dyes/pharmacology , Gene Library , Glucose/metabolism , Humans , Hydrogen Bonding , Molecular Conformation , Monosaccharide Transport Proteins/metabolism , Mutagenesis , Mutation , Periplasmic Binding Proteins/metabolism , Protein Binding
6.
Bioconjug Chem ; 18(6): 1841-6, 2007.
Article in English | MEDLINE | ID: mdl-17848078

ABSTRACT

Environmentally sensitive near-IR (NIR) dyes are useful fluorophores for various biosensor applications when tissue absorption, scattering, and autofluorescence are a leading concern. Biosensors operating in the NIR region (generally wavelengths >650 nm) would avoid interference from biological media and thereby facilitate relatively interference free sensing. Squaraine dyes are potential candidates to serve as reporter molecules due to their spectral properties in the NIR region, but none is commercially available for site-specific coupling to proteins through native or engineered thiols on cysteine. In this context, we have synthesized a thiol-reactive squaraine that displays fluorescence emission above 650 nm and have coupled the dye site-specifically to various mutants of glucose/galactose binding protein that contained an engineered cysteine for attachment. Mutant E149C/A213R/L238S ISQ GGBP gave a fluorescence change of +50% and a binding constant of 12 mM, which is in the human physiological range for glucose.


Subject(s)
Benzothiazoles/chemistry , Cyclobutanes/chemistry , Phenols/chemistry , Sulfhydryl Compounds/chemistry , Biosensing Techniques , Models, Molecular , Molecular Structure , Spectrometry, Fluorescence , Spectrophotometry, Infrared
7.
Diabetes Technol Ther ; 8(3): 261-8, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16800747

ABSTRACT

BACKGROUND: Fluorescent biosensors based on galactose/glucose binding protein (GGBP) and environmentally sensitive derivatives of the phenoxazine dye Nile Red are described. These biosensors are proposed as the sensing platform for a minimally invasive, continuous glucose monitoring system that can be implanted under the skin and read transdermally using an external fluorometer. METHODS: To construct the biosensors, the thiol-reactive Nile Red derivatives INR and IANR were prepared and conjugated to GGBP proteins possessing cysteine mutations that were designed for optimal site-specific fluorophore attachment. The attachment sites were selected to maximize the local environment change for attached dyes between the bound and unbound conformations of GGBP. RESULTS: Fluorescence responses at the selected cysteine sites of GGBP upon binding to glucose showed that the conjugates typically yielded fluorescence emission around 640-650 nm with up to 50% changes in fluorescence intensity. Conjugate E149C/A213C/L238S INR GGBP also displayed glucose binding in the human physiological range (K (D) = 7.4 mM). CONCLUSIONS: The phenoxazine derivatives fluoresced at longer wavelengths (>600 nm) approaching the near-infrared spectral window, where interference from scattering and tissue absorbance are minimal. Ultimately, we expect that monitoring systems based on GGBP and longwavelength dyes will be implanted for up to 6 months and can be used to transmit information through the skin to an external monitor.


Subject(s)
Biosensing Techniques , Fluorescent Dyes , Glucose/analysis , Glucose/chemistry , Oxazines , Escherichia coli Proteins , Models, Molecular , Monosaccharide Transport Proteins , Mutagenesis, Site-Directed , Protein Conformation , Spectrometry, Fluorescence
8.
Bioconjug Chem ; 17(2): 387-92, 2006.
Article in English | MEDLINE | ID: mdl-16536470

ABSTRACT

Two environmentally sensitive, long-wavelength fluorescent phenoxazine derivatives, INR and IANR, were synthesized with linkers for conjugation to the thiol group of cysteine in binding proteins. The linkers were designed based on the attachment sites at two different positions on the phenoxazine, which were chosen in order to study the orientation of the dye with respect to the binding protein. Conjugation of the dyes to the S337C maltose binding protein (MBP) mutant provided conjugates of these dyes that are capable of detecting maltose with different sensitivities. The dye INR gave a 3-fold (+200%) change in fluorescence intensity upon maltose binding when conjugated to S337C MBP with a binding constant (K(d)) of 435 microM. The fluorescence change for IANR was only 20% and the K(d) was 1.4 mM. Conformational analysis of the dyes by molecular modeling suggested that the linker in IANR imparted greater conformational freedom to the dye, resulting in little change in environment between the open and the closed-form conformations. The linker in INR, on the other hand, showed restricted motion, which placed the dye in different environments in the open and closed forms of the protein. Thus, design and placement of the linker play a critical role in the performance of these dyes as environmentally sensitive probes.


Subject(s)
Biosensing Techniques , Fluorescent Dyes , Oxazines/chemistry , Oxazines/chemical synthesis , Sulfhydryl Compounds/chemistry , Carrier Proteins/genetics , Carrier Proteins/metabolism , Fluorescent Dyes/chemical synthesis , Fluorescent Dyes/chemistry , Maltose/metabolism , Maltose-Binding Proteins , Models, Molecular , Molecular Sequence Data , Molecular Structure , Protein Binding , Protein Conformation
9.
Proteins ; 56(4): 828-38, 2004 Sep 01.
Article in English | MEDLINE | ID: mdl-15281134

ABSTRACT

Many proteins change their conformation upon ligand binding. For instance, bacterial periplasmic binding proteins (bPBPs), which transport nutrients into the cytoplasm, generally consist of two globular domains connected by strands, forming a hinge. During ligand binding, hinge motion changes the conformation from the open to the closed form. Both forms can be crystallized without a ligand, suggesting that the energy difference between them is small. We applied Simplicial Neighborhood Analysis of Protein Packing (SNAPP) as a method to evaluate the relative stability of open and closed forms in bPBPs. Using united residue representation of amino acids, SNAPP performs Delaunay tessellation of the protein, producing an aggregate of space-filling, irregular tetrahedra with nearest neighbor residues at the vertices. The SNAPP statistical scoring function is derived from log-likelihood scores for all possible quadruplet compositions of amino acids found in a representative subset of the Protein Data Bank, and the sum of the scores for a given protein provides the total SNAPP score. Results of scoring for bPBPs suggest that in most cases, the unliganded form is more stable than the liganded form, and this conclusion is corroborated by similar observations of other proteins undergoing conformation changes upon binding their ligands. The results of these studies suggest that the SNAPP method can be used to predict the relative stability of accessible protein conformations. Furthermore, the SNAPP method allows delineation of the role of individual residues in protein stabilization, thereby providing new testable hypotheses for rational site-directed mutagenesis in the context of protein engineering.


Subject(s)
Protein Conformation , Proteins/chemistry , Proteins/metabolism , Amino Acids/chemistry , Amino Acids/metabolism , Computational Biology/methods , Crystallography, X-Ray , Databases, Protein , Ions/chemistry , Ions/metabolism , Ligands , Monosaccharides/chemistry , Monosaccharides/metabolism , Oligopeptides/chemistry , Oligopeptides/metabolism , Oligosaccharides/chemistry , Oligosaccharides/metabolism , Protein Binding , Protein Structure, Quaternary , Vitamins/chemistry , Vitamins/metabolism
10.
Biosens Bioelectron ; 19(7): 653-60, 2004 Feb 15.
Article in English | MEDLINE | ID: mdl-14709382

ABSTRACT

The monitoring and management of blood glucose levels are key components for maintaining the health of people with diabetes. Traditionally, glucose monitoring has been based on indirect detection using electrochemistry and enzymes such as glucose oxidase or glucose dehydrogenase. Here, we demonstrate direct detection of glucose using a surface plasmon resonance (SPR) biosensor. By site-specifically and covalently attaching a known receptor for glucose, the glucose/galactose-binding protein (GGBP), to the SPR surface, we were able to detect glucose binding and determine equilibrium binding constants. The site-specific coupling was accomplished by mutation of single amino acids on GGBP to cysteine and subsequent thiol conjugation. The resulting SPR surfaces had glucose-specific binding properties consistent with known properties of GGBP. Further modifications were introduced to weaken GGBP-binding affinity to more closely match physiologically relevant glucose concentrations (1-30 mM). One protein with a response close to this glucose range was identified, the GGBP triple mutant E149C, A213S, L238S with an equilibrium dissociation constant of 0.5mM. These results suggest that biosensors for direct glucose detection based on SPR or similar refractive detection methods, if miniaturized, have the potential for development as continuous glucose monitoring devices.


Subject(s)
Glucose/analysis , Glucose/chemistry , Monosaccharide Transport Proteins/chemistry , Surface Plasmon Resonance/instrumentation , Amino Acid Substitution , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Equipment Design , Equipment Failure Analysis , Monosaccharide Transport Proteins/genetics , Mutagenesis, Site-Directed , Protein Engineering/methods , Recombinant Proteins/chemistry , Reproducibility of Results , Sensitivity and Specificity , Surface Plasmon Resonance/methods
SELECTION OF CITATIONS