Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Med Phys ; 51(4): 2621-2632, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37843975

ABSTRACT

BACKGROUND: Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. Dual-energy (DE) imaging, with its capability to quantify area density of specific materials, is well-suited to address such limitations, but only if the dual-energy projections are acquired with perfect spatial and temporal alignment and corrected for scatter. PURPOSE: In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free DE imaging with scatter correction in a single exposure. METHODS: The key components of our SSQI setup include a PM and DL detector, where the former enables scatter correction for the latter while the latter enables beam hardening correction for the former. The SSQI algorithm allows simultaneous recovery of two material-specific images and two scatter images using four sub-measurements from the PM encoding. The concept was first demonstrated using simulation of chest x-ray imaging for a COVID patient. For validation, we set up SSQI geometry on our tabletop system and imaged acrylic and copper slabs with known thicknesses (acrylic: 0-22.5 cm; copper: 0-0.9 mm), estimated scatter with our SSQI algorithm, and compared the material decomposition (MD) for different combinations of the two materials with ground truth. Second, we imaged an anthropomorphic chest phantom containing contrast in the coronary arteries and compared the MD with and without SSQI. Lastly, to evaluate SSQI in dynamic applications, we constructed a flow phantom that enabled dynamic imaging of iodine contrast. RESULTS: Our simulation study demonstrated that SSQI led to accurate scatter correction and MD, particularly for smaller focal blur and finer PM pitch. In the validation study, we found that the root mean squared error (RMSE) of SSQI estimation was 0.13 cm for acrylic and 0.04 mm for copper. For the anthropomorphic phantom, direct MD resulted in incorrect interpretation of contrast and soft tissue, while SSQI successfully distinguished them quantitatively, reducing RMSE in material-specific images by 38%-92%. For the flow phantom, SSQI was able to perform accurate dynamic quantitative imaging, separating contrast from the background. CONCLUSIONS: We demonstrated the potential of SSQI for robust quantitative x-ray imaging. The integration of SSQI is straightforward with the addition of a PM and upgrade to a DL detector, which may enable its widespread adoption, including in techniques such as radiography and dynamic imaging (i.e., real-time image guidance and cone-beam CT).


Subject(s)
Copper , Tomography, X-Ray Computed , Humans , X-Rays , Tomography, X-Ray Computed/methods , Cone-Beam Computed Tomography , Phantoms, Imaging , Algorithms , Scattering, Radiation
2.
Med Phys ; 50(7): 4459-4465, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37060293

ABSTRACT

BACKGROUND: High precision radiotherapy with small irradiator size has potential in many treatment applications involving small shallow targets, with small animal radio-neuromodulation as an intriguing example. A focused kV technique based on novel usage of polycapillary x-ray lenses can focus x-ray beams to <0.2 mm in diameter, which is ideal for such uses. PURPOSE: Such an application also requires high resolution CT images for treatment planning and setup. In this work, we demonstrate the feasibility of using a virtual focal spot generated with an x-ray lens to perform high-resolution CBCT acquisition. METHOD: The experiment with x-ray lens was set up on an x-ray tabletop system to generate a virtual focal spot. The flood field images with and without the x-ray lens were first compared. A pinhole image was acquired for the virtual focal spot and compared with the one acquired with the conventional focal spot without the lens. The planar imaging resolution with and without the lens were evaluated using a line pair resolution phantom. The spatial resolution of the two settings were estimated by reconstructing a 0.15-mm wire phantom and comparing its full width half maximum (FWHM). A CBCT scan of a rodent head was also acquired to further demonstrate the improved resolution using the x-ray lens. RESULT: The proposed imaging setup with x-ray lens had a limited exposure area of 5 cm by 5 cm on the detector, which was suitable for guiding radio-neuromodulation to a small target in rodent brain. Compared to conventional imaging acquisition with a measured x-ray focal spot of 0.395 mm FWHM, the virtual focal spot size was measured at 0.175 mm. The reduction in focal spot size with lens leads to an almost doubled planar imaging resolution and a 26% enhancement in 3D spatial resolution. A realistic CBCT acquisition of a rodent head mimicked the imaging acquisition step for radio-neuromodulation and further showed the improved visualization for fine structures. CONCLUSION: This work demonstrated that the focused kV x-ray technique was capable of generating small focal spot size of <0.2 mm, which substantially improved x-ray imaging resolution for small animal imaging.


Subject(s)
Head , Animals , X-Rays , Radiography , Phantoms, Imaging , Head/diagnostic imaging
3.
Article in English | MEDLINE | ID: mdl-36560977

ABSTRACT

Conventional x-ray imaging provides little quantitative information due to scatter, beam hardening, and overlaying tissues. A single-shot quantitative x-ray imaging (SSQI) method was previously developed to quantify material-specific densities in x-ray imaging by combining the use of a primary modulator (PM) and dual-layer (DL) detector. The feasibility of this concept was demonstrated with simulations using an iterative patch-based method. In this work, we propose a new algorithm pipeline for SSQI that enables accurate quantification and high computational efficiency. The DL images contain four measurements that are obtained behind the unattenuated and partially attenuated regions of the PM of each layer. Using the low-frequency property of scatter and a pre-calibrated material decomposition (MD), four unknowns (i.e., two scatter images and two material-specific images) are jointly recovered by directly solving four equations given by the four measurements. We tested this algorithm in simulations and further demonstrated its efficacy on chest phantom experiments. Through simulation, we show that the new method for MD is robust against scatter. Its performance improves with smaller PM pitch size and smaller focal spot blur. The RMSE in material-specific images compared to ground truth reduces by 52%-84% versus without scatter correction. For our experimental study, we successfully separated soft tissue and bone. The computational time for processing each view was ~8 s without optimization. The reported results further strengthen the potential of SSQI for widespread adoption, leading to quantitative imaging not only for x-ray imaging but also for real-time image guidance or cone-beam CT.

4.
J Med Imaging (Bellingham) ; 8(2): 023502, 2021 Mar.
Article in English | MEDLINE | ID: mdl-34368391

ABSTRACT

Purpose: The focal spot size and shape of an x-ray system are critical factors to the spatial resolution. Conventional approaches to characterizing the focal spot use specialized tools that usually require careful calibration. We propose an alternative to characterize the x-ray source's focal spot, simply using a rotating edge and flat-panel detector. Methods: An edge is moved to the beam axis, and an edge spread function (ESF) is obtained at a specific angle. Taking the derivative of the ESF provides the line spread function, which is the Radon transform of the focal spot in the direction parallel to the edge. By rotating the edge about the beam axis for 360 deg, we obtain a complete Radon transform, which is used for reconstructing the focal spot. We conducted a study on a clinical C-arm system with three focal spot sizes (0.3, 0.6, and 1.0 mm nominal size), then compared the focal spot imaged using the proposed method against the conventional pinhole approach. The full width at half maximum (FWHM) of the focal spots along the width and height of the focal spot were used for quantitative comparisons. Results: Using the pinhole method as ground truth, the proposed method accurately characterized the focal spot shapes and sizes. Quantitatively, the FWHM widths were 0.37, 0.65, and 1.14 mm for the pinhole method and 0.33, 0.60, and 1.15 mm for the proposed method for the 0.3, 0.6, and 1.0 mm nominal focal spots, respectively. Similar levels of agreement were found for the FWHM heights. Conclusions: The method uses a rotating edge to characterize the focal spot and could be automated in the future using a system's built-in collimator. The method could be included as part of quality assurance tests of image quality and tube health.

5.
Med Phys ; 48(10): 6482-6496, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34374461

ABSTRACT

PURPOSE: Metal artifact remains a challenge in cone-beam CT images. Many image domain-based segmentation methods have been proposed for metal artifact reduction (MAR), which require two-pass reconstruction. Such methods first segment metal from a first-pass reconstruction and then forward-project the metal mask to identify them in projections. These methods work well in general but are limited when the metal is outside the scan field-of-view (FOV) or when the metal is moving during the scan. In the former, even reconstructing with a larger FOV does not guarantee a good estimate of metal location in the projections; and in the latter, the metal location in each projection is difficult to identify due to motion. Single-pass methods that detect metal in single-energy projections have also been developed, but often have imperfect metal detection that leads to residual artifacts. In this work, we develop a MAR method using a dual-layer (DL) flat panel detector, which improves performance for single-pass reconstruction. METHODS: In this work, we directly detect metal objects in projections using dual-energy (DE) imaging that generates material-specific images (e.g., soft tissue and bone), where the metal stands out in bone images when nonuniform soft tissue background is removed. Metal is detected via simple thresholding, and entropy filtration is further applied to remove false-positive detections. A DL detector provides DE images with superior temporal and spatial registration and was used to perform the task. Scatter correction was first performed on DE raw projections to improve the accuracy of material decomposition. One phantom mimicking a liver biopsy setup and a cadaver head were used to evaluate the metal reduction performance of the proposed method and compared with that of a standard two-pass reconstruction, a previously published sinogram-based method using a Markov random field (MRF) model, and a single-pass projection-domain method using single-energy imaging. The phantom has a liver steering setup placed in a hollow chest phantom, with embedded metal and a biopsy needle crossing the phantom boundary. The cadaver head has dental fillings and a metal tag attached to its surface. The identified metal regions in each projection were corrected by interpolation using surrounding pixels, and the images were reconstructed using filtered backprojection. RESULTS: Our current approach removes metal from the projections, which is robust to FOV truncation during imaging acquisition. In case of FOV truncation, the method outperformed the two-pass reconstruction method. The proposed method using DE renders better accuracy in metal segmentation than the MRF method and single-energy method, which were prone to false-positive errors that cause additional streaks. For the liver steering phantom, the average spatial nonuniformity was reduced from 0.127 in uncorrected images to 0.086 using a standard two-pass reconstruction and to 0.077 using the proposed method. For the cadaver head, the average standard deviation within selected soft tissue regions ( σ s ) was reduced from 209.1 HU in uncorrected images to 69.1 HU using a standard two-pass reconstruction and to 46.8 HU using our proposed method. The proposed method reduced the processing time by 31% as compared with the two-pass method. CONCLUSIONS: We proposed a MAR method that directly detects metal in the projection domain using DE imaging, which is robust to truncation and superior to that of single-energy imaging. The method requires only a single-pass reconstruction that substantially reduces processing time compared with the standard two-pass metal reduction method.


Subject(s)
Artifacts , Image Processing, Computer-Assisted , Algorithms , Cone-Beam Computed Tomography , Phantoms, Imaging , Radiography
6.
Transfus Apher Sci ; 60(5): 103201, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34238707

ABSTRACT

BACKGROUND: Multiple factors contribute to anemia in patients with Hepatitis B virus (HBV)related acute-on-chronic liver failure (ACLF); however, the mechanism is unclear. The purpose of this study was to evaluate the clinical significance of the direct antiglobulin test (DAT) in patients with HBV related ACLF. METHODS: DAT was used to detect immunoglobulins and/or complement proteins on the surface of erythrocytes. RESULTS: We recruited 78 HBV-associated ACLF patients, 30 chronic hepatitis B(CHB)patients and 40 healthy people between October 2015 and May 2016. In HBV related ACLF patients, the hemoglobin concentration, number of erythrocytes, and hematocrit value were significantly lower, while the erythrocyte distribution width was significantly higher, compared to patients with CHB and healthy controls (HCs) (P < 0.001). The rates of DAT positivity in HBV related ACLF patients, CHB patients, and HCs were 62.8 %, 13.3 %, and 0%, respectively. DAT-positive ACLF patients exhibited lower Hb levels, older average age, as well as higher total bilirubin, alanine aminotransferase, and complement component 3 levels compared to DAT-negative patients. CONCLUSIONS: HBV related ACLF patients showed significant alterations in erythrocyte parameters, possibly reflecting disease development and severity. The high presence of erythrocyte autoantibodies suggested that immunologic clearance of erythrocytes contributed to multifactorial anemia in HBV related ACLF patients.


Subject(s)
Acute-On-Chronic Liver Failure/blood , Coombs Test/methods , Hemoglobins/analysis , Hepatitis B, Chronic/blood , Acute-On-Chronic Liver Failure/complications , Adult , Aged , Alanine Transaminase/blood , Bilirubin/blood , Complement System Proteins , Erythrocytes/cytology , Female , Hepatitis B, Chronic/complications , Humans , Male , Middle Aged , Reproducibility of Results
7.
ACS Appl Mater Interfaces ; 13(12): 14433-14439, 2021 Mar 31.
Article in English | MEDLINE | ID: mdl-33730482

ABSTRACT

Highly soluble d8-d10 heteronuclear phosphors afford an alternative approach to achieve high-efficiency organic light-emitting diodes (OLEDs) through a solution process. In this work, four highly phosphorescent d8-d10 heteronuclear complexes with significant Pt-Au interactions were prepared. By judicious selection of sterically hindered and π-conjugated substituents in triphosphine ligands, the phosphorescence is dramatically promoted through effectively prohibiting nonradiative thermal relaxation with an efficiency of 0.94-0.99 in doping films. Exploiting highly emissive Pt-Au complexes as phosphorescent dopants, ultrahigh-efficiency solution-processed OLEDs were attained. The peak current efficiency, power efficiency, and external quantum efficiency are 96.2 cd A-1, 65.0 lm W-1, and 26.4% for the green-emitting PtAu2 phosphor and 68.6 cd A-1, 42.5 lm W-1, and 25.1% for the orange-emitting Pt2Au phosphor, which represent the state-of-art for solution-processed OLEDs based on non-iridium phosphors.

8.
ACS Appl Mater Interfaces ; 12(51): 57264-57270, 2020 Dec 23.
Article in English | MEDLINE | ID: mdl-33306350

ABSTRACT

In this work, rational design of highly soluble and phosphorescent Ag-Au cluster complexes with exceptional [2]catenane structures is conducted using 1,8-diethynyl-9H-carbazole (H3decz) as a rigid U-shaped ligand with a distinguished hole-transport character. The self-assembly reaction of H3decz, Au+, and Ag+ generated phosphorescent Ag4Au6 cluster 1 (Φem = 0.22 in CH2Cl2) with H2decz- having a free ethynyl (-C≡CH) group. When the four free C≡CH groups in the Ag4Au6 complex 1 are further bound to four (PPh3)Au+ and four (PPh3)Ag+ moieties through M-acetylide linkages, the formation of Ag8Au10 cluster 2 not only eliminates nonradiative ethynyl C-H vibrational deactivation process but also improves dramatically the molecular rigidity so that the phosphorescent efficiency of the Ag8Au10 cluster 2 (Φem = 0.63) is nearly 3 times that of the Ag4Au6 cluster 1. The Ag8Au10 cluster structure is further rigidified using diphsophine Ph2P(CH2)4PPh2 (dppb) in place of PPh3 so that the phosphorescence of the Ag8Au10 cluster 3 (Φem = 0.77) is more efficient than that of 2. Making use of the Ag8Au10 clusters as phosphorescent dopants, high-efficiency solution-processed organic light-emitting diodes (OLEDs) were achieved with current efficiency (CE) and external quantum efficiency (EQE) of 47.2 cd A-1 and 15.7% for complex 2 and 50.5 cd A-1 and 14.9% for complex 3.

9.
Inorg Chem ; 59(18): 13326-13334, 2020 Sep 21.
Article in English | MEDLINE | ID: mdl-32862642

ABSTRACT

Metal-organic frameworks (MOFs) with cuprous-halide-aggregates have shown superiority as organic LED (OLED) and semiconductor materials, while engineering MOF flexibility by involving the expansion of cuprous aggregates remains a great challenge. In this particular work, a dissolution-recrystallization structural transformation (DRST) with the dramatic growth of CuI-I aggregates, from 2D NJNU-100 to 3D NJNU-101 has been successfully realized. The unsaturated coordination nodes (2-positional nitrogen atoms) in NJNU-100 have been demonstrated to be the driven force for DRST to NJNU-101 via the formation of coordination bonds. The structural transformation process was irreversible and observed with optical microscopy and powder XRD. The expansion of CuI-I aggregates was also computational simulated accompanying with the rotation of the neutral tripodal TTTMB ligand (1,3,5-tris(1,2,4-triazol-1-ylmethyl)-2,4,6-trimethylbenzene) and the reduction of CuII to CuI. Moreover, the intermediate product NJNU-102 was captured by adding the planar molecular anthrancene to shut down the reaction, where only partial 2-positional nitrogen atoms coordinated to the aggregates and the anthrancene was oxidized to anthraquinone. NJNU-102 has further confirmed that DRST involved the breakage and recombination of coordination bonds and the electron transfer. NJNU-100 and NJNU-101 could be applied as semiconductor and OLED materials. This work has provided insights for crystal engineering, especially for the construction of the CuIxXy aggregates, and illustrated that DRST could be controlled with a rational design (as the unsaturated coordination modes).

10.
Med Phys ; 47(8): 3332-3343, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32347561

ABSTRACT

PURPOSE: Dual-energy (DE) x-ray imaging has many clinical applications in radiography, fluoroscopy, and CT. This work characterizes a prototype dual-layer (DL) flat-panel detector (FPD) and investigates its DE imaging capabilities for applications in two-dimensional (2D) radiography/fluoroscopy and quantitative three-dimensional (3D) cone-beam CT. Unlike other DE methods like kV switching, a DL FPD obtains DE images from a single exposure, making it robust against patient and system motion. METHODS: The DL FPD consists of a top layer with a 200 µm-thick CsI scintillator coupled to an amorphous silicon (aSi) FPD of 150 µm pixel size and a bottom layer with a 550 µm thick CsI scintillator coupled to an identical aSi FPD. The two layers are separated by a 1-mm Cu filter to increase spectral separation. Images (43 × 43 cm2 active area) can be readout in 2 × 2 binning mode (300 µm pixels) at up to 15 frames per second. Detector performance was first characterized by measuring the MTF, NPS, and DQE for the top and bottom layers. For 2D applications, a qualitative study was conducted using an anthropomorphic thorax phantom containing a porcine heart with barium-filled coronary arteries (similar to iodine). Additionally, fluoroscopic lung tumor tracking was investigated by superimposing a moving tumor phantom on the thorax phantom. Tracking accuracies of single-energy (SE) and DE fluoroscopy were compared against the ground truth motion of the tumor. For 3D quantitative imaging, a phantom containing water, iodine, and calcium inserts was used to evaluate overall DE material decomposition capabilities. Virtual monoenergetic (VM) images ranging from 40 to 100 keV were generated, and the optimal VM image energy which achieved the highest image uniformity and maximum contrast-to-noise ratio (CNR) was determined. RESULTS: The spatial resolution of the top layer was substantially higher than that of the bottom layer (top layer 50% MTF = 2.2 mm-1 , bottom layer = 1.2 mm-1 ). A substantial increase in NNPS and reduction in DQE were observed for the bottom layer mainly due to photon loss within the top layer and Cu filter. For 2D radiographic and fluoroscopic applications, the DL FPD was capable of generating high-quality material-specific images separating soft tissue from bone and barium. For lung tumor tracking, DE fluoroscopy yielded more accurate results than SE fluoroscopy, with an average reduction in the root mean square error (RMSE) of over 10×. For the DE-CBCT studies, accurate basis material decompositions were obtained. The estimated material densities were 294.68  ±  17.41 and 92.14  ±  15.61 mg/ml for the 300 and 100 mg/ml calcium inserts, respectively, and 8.93  ±  1.45, 4.72  ±  1.44, and 2.11  ±  1.32 mg/ml for the 10, 5, and 2 mg/ml iodine inserts, respectively, with an average error of less than 5%. The optimal VM image energy was found to be 60 keV. CONCLUSIONS: We characterized a prototype DL FPD and demonstrated its ability to perform accurate single-exposure DE radiography/fluoroscopy and DE-CBCT. The merits of the DL detector approach include superior spatial and temporal registration between its constituent images, and less complicated acquisition sequences.


Subject(s)
Cone-Beam Computed Tomography , Imaging, Three-Dimensional , Animals , Fluoroscopy , Humans , Phantoms, Imaging , Radiography , Swine
11.
J Xray Sci Technol ; 28(3): 405-426, 2020.
Article in English | MEDLINE | ID: mdl-32333575

ABSTRACT

BACKGROUND: High-resolution, low-noise detectors with minimal dead-space at chest-wall could improve posterior coverage and microcalcification visibility in the dedicated cone-beam breast CT (CBBCT). However, the smaller field-of-view necessitates laterally-shifted detector geometry to enable optimizing the air-gap for x-ray scatter rejection. OBJECTIVE: To evaluate laterally-shifted detector geometry for CBBCT with clinical projection datasets that provide for anatomical structures and lesions. METHODS: CBBCT projection datasets (n = 17 breasts) acquired with a 40×30 cm detector (1024×768-pixels, 0.388-mm pixels) were truncated along the fan-angle to emulate 20.3×30 cm, 22.2×30 cm and 24.1×30 cm detector formats and correspond to 20, 120, 220 pixels overlap in conjugate views, respectively. Feldkamp-Davis-Kress (FDK) algorithm with 3 different weighting schemes were used for reconstruction. Visual analysis for artifacts and quantitative analysis of root-mean-squared-error (RMSE), absolute difference between truncated and 40×30 cm reconstructions (Diff), and its power spectrum (PSDiff) were performed. RESULTS: Artifacts were observed for 20.3×30 cm, but not for other formats. The 24.1×30 cm provided the best quantitative results with RMSE and Diff (both in units of µ, cm-1) of 4.39×10-3±1.98×10-3 and 4.95×10-4±1.34×10-4, respectively. The PSDiff (>0.3 cycles/mm) was in the order of 10-14µ2mm3 and was spatial-frequency independent. CONCLUSIONS: Laterally-shifted detector CBBCT with at least 220 pixels overlap in conjugate views (24.1×30 cm detector format) provides quantitatively accurate and artifact-free image reconstruction.


Subject(s)
Breast/diagnostic imaging , Cone-Beam Computed Tomography/methods , Mammography/methods , Algorithms , Breast Neoplasms/diagnostic imaging , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted , Retrospective Studies
12.
Article in English | MEDLINE | ID: mdl-34248248

ABSTRACT

Metal artifact remains a challenge in cone-beam CT images. Many two-pass metal artifact reduction methods have been proposed, which work fairly well, but are limited when the metal is outside the scan field-of-view (FOV) or when the metal is moving during the scan. In the former, even reconstructing with a larger FOV does not guarantee a good estimate of metal location in the projections; and in the latter, the metal location in each projection is difficult to identify due to motion. Furthermore, two-pass methods increase the total reconstruction time. In this study, a projection-based metal detection and correction method with a dual layer detector is investigated. The dual layer detector provides dual energy images with perfect temporal and spatial registration in each projection, which aid in the identification of metal. A simple phantom with metal wires (copper) and a needle (steel) is used to evaluate the projection-based metal artifact reduction method from a dual layer scan and compared with that of a single layer scan. Preliminary results showed enhanced ability to identify metal regions, leading to substantially reduced metal artifact in reconstructed images. In summary, an effective single-pass, projection-domain method using a dual layer detector has been demonstrated, and it is expected to be robust against truncation and motion.

13.
Article in English | MEDLINE | ID: mdl-34248249

ABSTRACT

Cone-beam CT (CBCT) is widely used in diagnostic imaging and image-guided procedures, leading to an increasing need for advanced CBCT techniques, such as dual energy (DE) imaging. Previous studies have shown that DE-CBCT can perform quantitative material decomposition, including quantification of contrast agents, electron density, and virtual monoenergetic images. Currently, most CBCT systems perform DE imaging using a kVp switching technique. However, the disadvantages of this method are spatial and temporal misregistration as well as total scan time increase, leading to errors in the material decomposition. DE-CBCT with a dual layer flat panel detector potentially overcomes these limitations by acquiring the dual energy images simultaneously. In this work, we investigate the DE imaging performance of a prototype dual layer detector by evaluating its material decomposition capability and comparing its performance to that of the kVp switching method. Two sets of x-ray spectra were used for kVp switching: 80/120 kVp and 80/120 kVp + 1 mm Cu filtration. Our results show the dual layer detector outperforms kVp switching at 80/120 kVp with matched dose. The performance of kVp switching was better by adding 1 mm copper filtration to the high energy images (80/120 kVp + 1 mm Cu), though the dual layer detector still provided comparable performance for material decomposition tasks. Overall, both the dual layer detector and kVp switching methods provided quantitative material decomposition images in DE-CBCT, with the dual layer detector having additional potential advantages.

14.
Article in English | MEDLINE | ID: mdl-34295015

ABSTRACT

The size and shape of an x-ray source's focal spot is a critical factor in the imaging system's overall spatial resolution. The conventional approach to imaging the focal spot uses a pinhole camera, but this requires careful, manual measurements. Instead, we propose a novel alternative, simply using the collimator available on many x-ray systems. After placing the edge of a collimator blade in the center of the beam, we can obtain an image of its edge spread function (ESF). Each ESF provides information about the focal spot distribution - specifically, the parallel projection of the focal spot in the direction parallel to the edge. If the edge is then rotated about the beam axis, each image provides a different parallel projection of the focal spot until a complete Radon transform of the focal spot distribution is obtained. The focal spot can then be reconstructed by the inverse Radon transform, or parallel-beam filtered backprojection. We conducted a study on a clinical C-arm system with 3 focal spot sizes (0.3, 0.6, 1.0 mm nominal size), comparing the focal spot obtained using the rotating edge method against the conventional pinhole approach. Our results demonstrate accurate characterization of the size and shape of the focal spot.

15.
Phys Med Biol ; 64(6): 065015, 2019 03 13.
Article in English | MEDLINE | ID: mdl-30721886

ABSTRACT

The quantitative use of cone beam computed tomography (CBCT) in radiation therapy is limited by severe shading artifacts, even with system embedded correction. We recently proposed effective shading correction methods, using planning CT (pCT) as prior information to estimate low-frequency errors in either the projection domain or image domain. In this work, we further improve the clinical practicality of our previous methods by removing the requirement of prior pCT images. Clinical CBCT images are typically composed of a limited number of tissues. By utilizing the low frequency characteristic of shading distribution, we first generate a 'shading-free' template image by enforcing uniformity on CBCT voxels of the same tissue type via a technique named partitioned tissue classification. Only a small subset of voxels in the template image are used in the correction process to generate sparse samples of shading artifacts. Local filtration, a Fourier transform based algorithm, is employed to efficiently process the sparse errors to compute a full-field distribution of shading artifacts for CBCT correction. We evaluate the method's performance using an anthropomorphic pelvis phantom and 6 pelvis patients. The proposed method improves the image quality of CBCT for both phantom and patients to a level matching that of pCT. On the pelvis phantom, the signal non-uniformity (SNU) is reduced from 12.11% to 3.11% and 8.40% to 2.21% on fat and muscle, respectively. The maximum CT number error is reduced from 70 to 10 HU and 73 to 11 HU on fat and muscle, respectively. On patients, the average SNU is reduced from 9.22% to 1.06% and 11.41% to 1.67% on fat and muscle, respectively. The maximum CT number error is reduced from 95 to 9 HU and 88 to 8 HU on fat and muscle, respectively. The typical processing time for one CBCT dataset is about 45 s on a standard PC.


Subject(s)
Algorithms , Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Pelvis/diagnostic imaging , Phantoms, Imaging , Humans , Male , Muscles/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging
16.
Article in English | MEDLINE | ID: mdl-34248247

ABSTRACT

Quantitative short-scan cone beam CT (CBCT) is impeded by streaking and shading artifacts. Streaking artifacts can be caused by approximate handling of data redundancy in short-scan FDK with Parker's weighting, while shading artifacts are caused by scatter and beam hardening effects. In this work, we improve the image quality of short-scan CBCT by removing the streaking artifacts using a previously proposed algorithm in a framework of filtered backprojection with shift-invariant filtering and equal weighting. An efficient image domain shading correction using sparse samples is subsequently applied to further improve the image uniformity. The improved image quality is shown for this approach, both in visual appearance and quantitative measurements of three clinical head scans.

17.
Dalton Trans ; 47(19): 6742-6753, 2018 May 15.
Article in English | MEDLINE | ID: mdl-29713716

ABSTRACT

A series of Ag(i) and Cu(i) complexes [Ag3(L1)2][PF6]3 (8), [Ag3(L2)2][PF6]3 (9), [Cu(L1)][PF6] (10) and [Cu(L2)][PF6] (11) have been synthesized by reactions of the tridentate amine-bis(N-heterocyclic carbene) ligand precursors [H2L1][PF6]2 (6) and [H2L2][PF6]2 (7) with Ag2O and Cu2O, respectively. Complexes 10 and 11 can also be obtained by transmetalation of 8 and 9, respectively, with 3.0 equiv. of CuCl. A heterometallic Cu/Ag-NHC complex [Cu2Ag(L1)2(CH3CN)2][PF6]3 (12) is formed by the reaction of 8 with 2.0 equiv. of CuCl. All complexes have been characterized by NMR, electrospray ionization mass spectrometry (ESI-MS), and single-crystal X-ray diffraction studies. The luminescence properties of 10-12 in solution and the solid state have been studied. At room temperature, 10-12 exhibit evident luminescence in solution and the solid state. The emission wavelengths are found to be identical at 483 nm in CH3CN, but they are 484, 480 and 592 nm in the solid state for 10-12, respectively. These results suggest that 12 dissociates into two molecules of 10 and Ag(i) ions in solution. Complex 12 is the first luminescent heterometallic Cu/Ag-NHC complex.

18.
Med Phys ; 45(1): 191-201, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29159941

ABSTRACT

PURPOSE: Dedicated cone beam breast CT (CBBCT) suffers from x-ray scatter contamination. We aim to identify the source of the significant difference between the scatter distributions estimated by two recent methods proposed by our group and to investigate its effect on CBBCT image quality. METHOD: We recently proposed two novel methods of scatter correction for CBBCT, using a library based (LB) technique and a forward projection (FP) model. Despite similar enhancement on CBBCT image qualities, these two methods obtain very different scatter distributions. We hypothesize that the off-focus radiation (OFR) is the contributor and results in nontrivial signals in x-ray projections, which is ignored in the scatter estimation via the LB method. Experiments using a thin wire test tool are designed to study the effect of OFR on CBBCT spatial resolution by measuring the point spread function (PSF) and the modulation transfer function (MTF). A narrow collimator setting is used to suppress the OFR-induced signals. In addition, "PSFs" and "MTFs" are measured on clinical CBBCT images obtained by the LB and FP methods using small calcifications as point sources. The improvement of spatial resolution achieved by suppressing OFR in the wire experiment as well as in the clinical study is quantified by the improvement ratios of PSFs and spatial frequencies at different MTF values. Our hypothesis that OFR causes the imaging difference between the FP and LB methods is verified if these ratios obtained from experimental and clinical data are consistent. RESULTS: In the wire experiment, the results show that suppression of OFR increases the maximum signal of the PSF by about 14% and reduces the full-width-at-half-maximum (FWHM) by about 12.0%. Similar improvement on spatial resolution is achieved by the FP method compared with the LB method in the patient study. The improvement ratios of spatial frequencies at different MTF values without OFR match very well in both studies at a level of around 16%, with an average root-mean-square difference of 0.47%. CONCLUSION: The results of the wire experiment and the clinical study indicate that the main difference between the LB and FP methods is whether the OFR-induced signals are included after scatter correction. Our study further shows that OFR significantly affects the image spatial resolution of CBBCT, indicating that the visualization of micro-calcifications is susceptible to OFR contamination. Our finding is therefore important in further improvement of diagnostic performance of CBBCT.


Subject(s)
Breast/diagnostic imaging , Cone-Beam Computed Tomography , Image Processing, Computer-Assisted/methods , Scattering, Radiation , Humans
19.
Med Phys ; 44(5): 1796-1808, 2017 May.
Article in English | MEDLINE | ID: mdl-28261827

ABSTRACT

PURPOSE: The image quality of cone beam computed tomography (CBCT) is limited by severe shading artifacts, hindering its quantitative applications in radiation therapy. In this work, we propose an image-domain shading correction method using planning CT (pCT) as prior information which is highly adaptive to clinical environment. METHOD: We propose to perform shading correction via sparse sampling on pCT. The method starts with a coarse mapping between the first-pass CBCT images obtained from the Varian TrueBeam system and the pCT. The scatter correction method embedded in the Varian commercial software removes some image errors but the CBCT images still contain severe shading artifacts. The difference images between the mapped pCT and the CBCT are considered as shading errors, but only sparse shading samples are selected for correction using empirical constraints to avoid carrying over false information from pCT. A Fourier-Transform-based technique, referred to as local filtration, is proposed to efficiently process the sparse data for effective shading correction. The performance of the proposed method is evaluated on one anthropomorphic pelvis phantom and 17 patients, who were scheduled for radiation therapy. (The codes of the proposed method and sample data can be downloaded from https://sites.google.com/view/linxicbct) RESULTS: The proposed shading correction substantially improves the CBCT image quality on both the phantom and the patients to a level close to that of the pCT images. On the phantom, the spatial nonuniformity (SNU) difference between CBCT and pCT is reduced from 74 to 1 HU. The root of mean square difference of SNU between CBCT and pCT is reduced from 83 to 10 HU on the pelvis patients, and from 101 to 12 HU on the thorax patients. The robustness of the proposed shading correction is fully investigated with simulated registration errors between CBCT and pCT on the phantom and mis-registration on patients. The sparse sampling scheme of our method successfully avoids false structures in the corrected CBCT even when the maximum registration error is as high as 8 mm. CONCLUSION: We develop an effective shading correction algorithm for CBCT readily implementable on clinical data as a software plug-in without modifications of current imaging hardware and protocol. The algorithm is directly applied on the output images from a commercial CBCT scanner with high computational efficiency and negligible memory burden.


Subject(s)
Cone-Beam Computed Tomography , Fourier Analysis , Phantoms, Imaging , Algorithms , Humans , Pelvis/diagnostic imaging
20.
Med Phys ; 44(6): 2312-2320, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28295375

ABSTRACT

PURPOSE: The quality of dedicated cone-beam breast CT (CBBCT) imaging is fundamentally limited by x-ray scatter contamination due to the large irradiation volume. In this paper, we propose a scatter correction method for CBBCT using a novel forward-projection model with high correction efficacy and reliability. METHOD: We first coarsely segment the uncorrected, first-pass, reconstructed CBBCT images into binary-object maps and assign the segmented fibroglandular and adipose tissue with the correct attenuation coefficients based on the mean x-ray energy. The modified CBBCT are treated as the prior images toward scatter correction. Primary signals are first estimated via forward projection on the modified CBBCT. To avoid errors caused by inaccurate segmentation, only sparse samples of estimated primary are selected for scatter estimation. A Fourier-Transform based algorithm, herein referred to as local filtration hereafter, is developed to efficiently estimate the global scatter distribution on the detector. The scatter-corrected images are obtained by removing the estimated scatter distribution from measured projection data. RESULTS: We evaluate the method performance on six patients with different breast sizes and shapes representing the general population. The results show that the proposed method effectively reduces the image spatial non-uniformity from 8.27 to 1.91% for coronal views and from 6.50 to 3.00% for sagittal views. The contrast-to-deviation ratio is improved by an average factor of 1.41. Comparisons on the image details reveal that the proposed scatter correction successfully preserves fine structures of fibroglandular tissues that are lost in the segmentation process. CONCLUSION: We propose a highly practical and efficient scatter correction algorithm for CBBCT via a forward-projection model. The method is attractive in clinical CBBCT imaging as it is readily implementable on a clinical system without modifications in current imaging protocols or system hardware.


Subject(s)
Algorithms , Cone-Beam Computed Tomography , Humans , Phantoms, Imaging , Reproducibility of Results , Scattering, Radiation , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...