Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Microsyst Nanoeng ; 10: 64, 2024.
Article in English | MEDLINE | ID: mdl-38784374

ABSTRACT

Flexible sensors have been widely studied for use in motion monitoring, human‒machine interactions (HMIs), personalized medicine, and soft intelligent robots. However, their practical application is limited by their low output performance, narrow measuring range, and unidirectional force detection. Here, to achieve flexibility and high performance simultaneously, we developed a flexible wide-range multidimensional force sensor (FWMFS) similar to bones embedded in muscle structures. The adjustable magnetic field endows the FWMFS with multidimensional perception for detecting forces in different directions. The multilayer stacked coils significantly improved the output from the µV to the mV level while ensuring FWMFS miniaturization. The optimized FWMFS exhibited a high voltage sensitivity of 0.227 mV/N (0.5-8.4 N) and 0.047 mV/N (8.4-60 N) in response to normal forces ranging from 0.5 N to 60 N and could detect lateral forces ranging from 0.2-1.1 N and voltage sensitivities of 1.039 mV/N (0.2-0.5 N) and 0.194 mV/N (0.5-1.1 N). In terms of normal force measurements, the FWMFS can monitor finger pressure and sliding trajectories in response to finger taps, as well as measure plantar pressure for assessing human movement. The plantar pressure signals of five human movements collected by the FWMFS were analyzed using the k-nearest neighbors classification algorithm, which achieved a recognition accuracy of 92%. Additionally, an artificial intelligence biometric authentication system is being developed that classifies and recognizes user passwords. Based on the lateral force measurement ability of the FWMFS, the direction of ball movement can be distinguished, and communication systems such as Morse Code can be expanded. This research has significant potential in intelligent sensing and personalized spatial recognition.

2.
Micromachines (Basel) ; 15(4)2024 Apr 14.
Article in English | MEDLINE | ID: mdl-38675335

ABSTRACT

High-performance vector hydrophones have been gaining attention for underwater target-monitoring applications. Nevertheless, there exists the mutual constraint between sensitivity and bandwidth of a single hydrophone. To solve this problem, a four-unit array piezoelectric bionic MEMS vector hydrophone (FPVH) was developed in this paper, which has a cross-beam and a bionic fish-lateral-line-nerve-cell-cilia unit array structure. Simulation analysis and optimization in the design of the bionic microstructure have been performed by COMSOL 6.1 software to determine the structure dimensions and the lead zirconate titanate (PZT) thin film distribution. The FPVH was manufactured using MEMS technology and tested in a standing wave bucket. The results indicate that the FPVH has a sensitivity of up to -167.93 dB@1000 Hz (0 dB = 1 V/µPa), which is 12 dB higher than that of the one-unit piezoelectric MEMS vector hydrophone (OPVH). Additionally, the working bandwidth of the FPVH reaches 20 Hz~1200 Hz, exhibiting a good cosine curve with an 8-shape. This work paves a new way for the development of multi-unit piezoelectric vector hydrophones for underwater acoustic detectors.

3.
Micromachines (Basel) ; 14(8)2023 Aug 14.
Article in English | MEDLINE | ID: mdl-37630134

ABSTRACT

In response to the growing demand for high-sensitivity accelerometers in vector hydrophones, a piezoelectric MEMS accelerometer (PMA) was proposed, which has a four-cantilever beam integrated inertial mass unit structure, with the advantages of being lightweight and highly sensitive. A theoretical energy harvesting model was established for the piezoelectric cantilever beam, and the geometric dimensions and structure of the microdevice were optimized to meet the vibration pickup conditions. The sol-gel and annealing technology was employed to prepare high-quality PZT thin films on silicon substrate, and accelerometer microdevices were manufactured by using MEMS technology. Furthermore, the MEMS accelerometer was packaged for testing on a vibration measuring platform. Test results show that the PMA has a resonant frequency of 2300 Hz. In addition, there is a good linear relationship between the input acceleration and the output voltage, with V = 8.412a - 0.212. The PMA not only has high sensitivity, but also has outstanding anti-interference ability. The accelerometer structure was integrated into a vector hydrophone for testing in a calibration system. The results show that the piezoelectric vector hydrophone (PVH) has a sensitivity of -178.99 dB@1000 Hz (0 dB = 1 V/µPa) and a bandwidth of 20~1100 Hz. Meanwhile, it exhibits a good "8" shape directivity and consistency of each channel. These results demonstrate that the piezoelectric MEMS accelerometer has excellent capabilities suitable for use in vector hydrophones.

4.
Materials (Basel) ; 17(1)2023 Dec 30.
Article in English | MEDLINE | ID: mdl-38204056

ABSTRACT

Metal oxide semiconductors (MOSs) hold great promise for electronic devices such as gas sensors. The utilization of ZnO as a conductometric gas sensor material can be traced back to its early stages; however, its application has primarily been limited to high-temperature environments. A gas sensor based on highly porous and interconnected 3D networks of ZnO tetrapod (ZnO-T) micro-nano structures was fabricated via an easy chemical vapor deposition (CVD) method. Homemade instruments were utilized to evaluate the gas-sensing of the sample at room temperature. It exhibited good gas-sensing at room temperature, particularly with a response of up to 338.80% toward 1600 ppm ethanol, while also demonstrating remarkable repeatability, stability, and selectivity. Moreover, the unique gas-sensing properties of ZnO-T at room temperature can be reasonably explained by considering the effect of van der Waals forces in physical adsorption and the synergistic effect of carrier concentration and mobility. The aforementioned statement presents an opportunity for the advancement of gas sensors utilizing ZnO at room temperature.

SELECTION OF CITATIONS
SEARCH DETAIL
...