Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Biochem ; 668: 115090, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36870552

ABSTRACT

It is particularly meaningful to therapeutic drug monitoring (TDM) of mycophenolic acid (MPA) for transplant patients to maximize the drug efficacy and minimize the adverse effect. In this study, a novel fluorescence and colorimetric dual-readout probe was put forward to fast and reliable detect MPA. The blue fluorescence of MPA was largely enhanced in the presence of poly (ethylenimine) (PEI), while the red fluorescence of CdTe@SiO2 (silica-coated CdTe quantum dots) provided a reliable reference signal. Hence, combining PEI70,000 and CdTe@SiO2, a fluorescence and colorimetric dual-readout probe could be constructed. For fluorescence measurement of MPA, the linearity was obtained in the MPA concentration range of 0.5-50 µg/mL, with a limit of detection (LOD) of 33 ng/mL. For the visual detection, the fluorescent colorimetric card was established in the MPA concentration from 0.5 to 50 µg/mL corresponding to the fluorescence color from red to violet and then to blue, which could be used for semi-quantification. Furthermore, in the light of the ColorCollect APP by the smartphone, the ratio of blue and red brightness values was linear with the MPA concentration from 1 to 50 µg/mL; thus, quantification of MPA could be realized by APP with the LOD of 83 ng/mL. The developed method was successfully applied to the analysis of MPA in the plasma samples of three patients after oral administration of mycophenolate mofetil, which was the prodrug of MPA. The result was comparable to those obtained by the clinically widely-used enzyme multiplied immunoassay technique. The developed probe was fast, cost-effective and operational convenience, and possessed high potential for TDM of MPA.


Subject(s)
Cadmium Compounds , Quantum Dots , Humans , Mycophenolic Acid , Silicon Dioxide , Polyethyleneimine , Colorimetry , Tellurium , Fluorescent Dyes
2.
World J Emerg Med ; 12(3): 198-201, 2021.
Article in English | MEDLINE | ID: mdl-34141034

ABSTRACT

BACKGROUND: Stent under-expansion is a main cause of acute coronary syndrome (ACS), which can lead to serious clinical outcomes. The rotational atherectomy of underexpanded coronary stents (academically called stent ablation, SA) by intravascular ultrasound (IVUS) may provide more visual reference in the intervention. We aim to analyze the procedural and long-term outcomes of the optimized strategy of SA in patients with ACS and to provide real-world data on this technique. METHODS: A total of 11 patients with ACS who underwent SA between April 2017 and January 2019 were analyzed. Clinical follow-ups were obtained either by telephone call or by scheduled visit. Clinical end-points included periprocedural and postprocedural myocardial infarction, stent thrombosis, target lesion revascularization, and major adverse cardiac events. RESULTS: The mean age of patients was 69.6±6.5 years, and five (45.5%) patients were males. All cases presented with unstable angina and were admitted with ACS. All patients required at least two burrs during the intervention and the size of the burr was selected based on the data of minimum lumen diameter (MLD), and the first and the second burr/stent MLD ratios were 0.93 (0.88-0.99) and 1.09 (1.02-1.14), respectively. Nine patients were treated with drug-eluting stents and two were treated with drug-coated balloons. There were no complications including no flow, perforation, or burr entrapment during the intervention. No in-hospital deaths or major adverse cardiac events were documented during the follow-up period. In our study, less contrast agent and a lower dose of radiation were used during the intervention. CONCLUSIONS: SA guided by IVUS can reduce the risk of complications, assess the results of surgery, inform the selection of stent size, and decrease the required dose of radiation and contrast.

SELECTION OF CITATIONS
SEARCH DETAIL
...