Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Magn Reson Imaging ; 43(3): 669-79, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26340144

ABSTRACT

BACKGROUND: To compare intravoxel incoherent motion (IVIM) and pharmacokinetic analysis dynamic contrast-enhanced MR imaging (DCE-MRI) in distinguishing lung cancer (LC) from benign solitary pulmonary lesions (SPL). METHODS: This prospective study was approved by the institutional review board, and written informed consent was obtained. Eighty-one consecutive patients considered for SPL underwent DW-IVIM and DCE-3T MRI. ADC, D, D*, and f were calculated with mono- and bi-exponential models. K(trans) , kep , ve , and vp were calculated with the modified Tofts model. Receiver operating characteristic (ROC) analysis was constructed to determine the diagnostic performance of IVIM and DCE-MRI in discriminating LC from benignity. RESULTS: There were 29 patients with a total of 48 benign SPL and 52 LCs: 4 small cell carcinomas (SCLC), 19 squamous cell carcinomas (SCC), and 29 adenocarcinomas (Adeno-Ca). Both Adeno-Ca (ADC: 1.19 ± 0.23 × 10(-3) mm(2) /s; D:1.12 ± 0.35 × 10(-3) mm(2) /s; ve :0.27 ± 0.13; K(trans) :0.24 ± 0.09 min(-1) ; kep :0.90 ± 0.45 min(-1) ) and SCC (1.13± 0.28 × 10(-3) mm(2) /s; 1.02 ± 0.32 10(-3) mm(2) /s; 0.32 ± 0.14; 0.26 ± 0.08 min(-1) ; 0.90 ± 0.48 min(-1) ) had significantly lower ADC, D, ve and larger K(trans) , kep than benignity (1.37 ± 0.38 × 10(-3) mm(2) /s; 1.34 ± 0.45 × 10(-3) mm(2) /s; 0.42 ± 0.19; 0.19 ± 0.08 min(-1) ; 0.53 ± 0.26 min(-1) ). D (72.2%) had significantly higher accuracy (72.2%) and higher sensitivity (91.3%) than other imaging indices (accuracy: 55.5-68.0%; sensitivity: 41.3-78.3%; all P < 0.01) except for accuracy in kep (70.8%; P > 0.05) in discriminating LC from benignity. K(trans) exhibited significantly higher specificity (84.6%) than the other indices (38.5-73.1%; P < 0.01). These results can be improved by combined D and K(trans) , leading to a sensitivity, specificity and accuracy of 94.2%, 92%, and 93.5%, respectively. CONCLUSION: IVIM-derived D and DCE-derived K(trans) are two promising parameters for differentiating LC from benignity.


Subject(s)
Adenocarcinoma/pathology , Carcinoma, Small Cell/pathology , Contrast Media/chemistry , Diffusion Magnetic Resonance Imaging , Lung Neoplasms/diagnostic imaging , Solitary Pulmonary Nodule/diagnostic imaging , Adenocarcinoma/diagnostic imaging , Aged , Carcinoma, Small Cell/diagnostic imaging , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/pathology , Cell Differentiation , Diagnosis, Differential , Female , Humans , Image Interpretation, Computer-Assisted/methods , Lung Neoplasms/pathology , Male , Middle Aged , Motion , Observer Variation , Pattern Recognition, Automated , Perfusion , Prospective Studies , ROC Curve , Reproducibility of Results , Sensitivity and Specificity , Solitary Pulmonary Nodule/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...